User manual FURUNO FS-1562 Operators Guide

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO FS-1562. We hope that this FURUNO FS-1562 user guide will be useful to you.


FURUNO FS-1562 Operators Guide: Download the complete user guide (174 Ko)

You may also download the following manuals related to this product:

   FURUNO FS-1562 Operators Manual (531 ko)

Manual abstract: user guide FURUNO FS-1562Operators Guide

Detailed instructions for use are in the User's Guide.

[. . . ] After the distress call has been transmitted, the following displays appear in order. Wait for distress acknowledgement. NATURE: UNDESIGNATED POS: 12°34N 123°45E AT 12:34 2182. 0 KHZ TELEPHONE DSC FREQ : TIME TO GO: 2187. 5 KHZ Distress acknowledge call received. When distress call is acknowledged by coast station (usually within 1 min to 2 min 45 seconds) FROM COAST: 001234567 SHIP IN DIST: 123456789 NATURE: UNDESIGNATED POS: 12°34N 123°45E AT 12:34 2182. 0 KHZ TELEPHONE STOP ALARM 2M10S 3. (In the dual control unit system, communication can be done from any control unit, after the distress alert has been transmitted. To restore priority to the #1 control unit after completion of distress communications, turn it off and on again. ) a) b) c) d) Say MAYDAY three times. Say "This is . . . " name of your vessel and your call sign three times. [. . . ] Send the call BEFORE entering an area of armed conflict. 5. 5. 1 Sending a neutral craft call 1. Press the [2/DSC] key and then push the [ENTER] knob to display the CALL TYPE menu. CALL TYPE STATION ID PRIORITY COM. FREQ DSC FREQ GO PSTN CALL TEST CALL : Safety ALL SHIPS : Telephone GROUP CALL : 2187. 5 kHz AREA CALL POSITION $ Rotate [ENTER] knob to scroll. 2. Rotate the [ENTER] knob to choose NEUTRAL and then push the [ENTER] knob. Push the [ENTER] knob to open the PRIORITY menu. message ** Compose: NEUTRAL ** CALL TYPE PRIORITY COM. TYPE DSC FREQ craft SAFETY : Safety URGENCY : TELEPHONE : 2187. 5 KHZ GO TO ALL VIEW 4. Rotate the [ENTER] knob to choose appropriate priority and then push the [ENTER] knob. Rotate the [ENTER] knob to choose communication type desired (radiotelephone or NBDP-FEC) and then push the [ENTER] knob. Push the [ENTER] knob to open the DSC FREQ menu. message 2187. 5 : Neutral ** Compose4207. 5 ** CALL TYPE PRIORITY COM. TYPE DSC FREQ craft 6312. 0 :8414. 5 Safety 12577. 0 : Telephone 16804. 5 kHz :2187. 5 VIEW GO TO ALL VIEW KHZ 8. Rotate the [ENTER] knob to choose appropriate frequency and then push the [ENTER] knob. $ message ** Compose: All ships ** INDIVIDUAL POLLING NEUTRAL MEDICAL RELAY ALL RELAY SEL DISTRESS 5-23 5 CALLING, RECEIVING ** Compose: message ** CALL TYPE NEUTRAL CRAFT PRIORITY COM. Inform all ships (by radiotelephone) that your ship is transporting medical supplies. For NBDP do the following: Sending message by NBDP Terminal Unit 1. Press the function key [F3] on the keyboard of the NBDP Terminal Unit to show the Operate menu. When you have finished sending your message, press the [F10] key to disconnect the line. 5. 6. 2 Receiving a medical transport call 1. When a medical transport call is received, the alarm sounds and the display looks as below. Medical transport call received. FROM SHIP: URGENCY TELEPHONE 123456789 2182. 0 KHZ STOP ALARM 2. The display changes as below. MAR-23-2002-23:59 * Received message * OK ECC: MEDICAL TRANSPORT 123456789 FROM SHIP: URGENCY TELEPHONE 2182. 0 KHZ GO TO ALL VIEW ALL VIEW 3. Press the [CANCEL] key to go to the radiotelephone screen to watch on frequency specified. 5-27 5 CALLING, RECEIVING Receiving message by NBDP Terminal Unit After receiving a neutral craft call, do the following to watch by NBDP Terminal Unit. The message from the sending station appears on your NBDP Terminal Unit. 5. 7 Polling Call Polling means confirming if own station is within communicating range with other station. This function only provides affirmative or negative response; it does not provide position information. Note that simultaneous polling to more than one station is not possible. 1 Polling 2 Acknowledge 3 Polling 4 Acknowledge 5. 7. 1 Sending a polling call 1. Press the [2/DSC] key followed by pushing the [ENTER] knob to open the CALL TYPE menu. CALL TYPE STATION ID PRIORITY COM. [. . . ] > 42 T-CPU BOARD 05P0732 OPEN: IEC 61162-1 (NMEA 0183) S2 SHORT: CIF J1 > > R60 330 R59 100 1SS355 C29 C28 100P 100P 3 CR11 1 U18 PC-400 4 5 TB6 R58 10 RD3_A 24 R59 10 RD3_B 25 Load requirements as a listener Isolation: Optocoupler Input impedance: 450 Max. voltage: ±15 V Threshold: 4 mA AP-22 APPENDIX Parts List This equipment contains complex modules in which fault diagnosis and repair down to component level are not practical (IMO A. 694(17)/8. 3. 1). Believes identifying these components is of no value for shipboard maintenance; therefore, they are not listed in this manual. Major modules can be located on the parts location photos on pages AP-26 thru AP-28. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FS-1562




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO FS-1562 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.