User manual FURUNO FI-302 OPERATORS MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO FI-302. We hope that this FURUNO FI-302 user guide will be useful to you.


FURUNO FI-302 OPERATORS MANUAL: Download the complete user guide (3397 Ko)

You may also download the following manuals related to this product:

   FURUNO FI-302 (2670 ko)

Manual abstract: user guide FURUNO FI-302OPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] The Nexus Network is capable of carrying data 10 times faster than NMEA 0183. The connection system, with a single 5 mm (1/5") cable and 4-pole jack plugs with cable protectors, makes the installation easy. The connections at the Server are colour coded and marked with a number for easy reference. The instruments large display gives you very good viewing possibilities from any angle, even in bright sunlight. [. . . ] At first power on after installation, you will be asked to press SET (PrESkey). This will give the instrument a logical ID number on the Nexus Network. To initialise the instrument, press SET on all installed digital instruments, one at the time. Note: Always wait for the text "Init OK" to be displayed, before you press SET on the next instrument!The Server automatically gives the first unit ID number 16, then 17 and so on. The order in which you press SET is the same order as the instruments will be given a logical ID number on the Nexus Network. The example shows that the instrument version number is 2. 0 and the given logical ID number is 16. On the lower line, the bus master version number (4. 8) and ID (0) is displayed. 4. 2 Re-initialising the instrument If two instruments by mistake have the same ID number, this can cause disturbance and block the information on the data bus. To re-initialise the instrument, press CLEAR during the power up sequence when version and ID numbers are displayed. The display self test is then re-started on all instruments and you will be asked to press KEY on each instrument as explained above. Note!If you do not succeed to re-initialise, we suggest you disconnect all but one instrument with the same ID number, then repeat the above procedure. 15 5 Operation 5. 1 About this manual · · · In this manual each time a push-button is refereed to, the push-button name will appear in bold and CAPITAL letters example PAGE. Each time a function is mentioned in the text, it will be in brackets and in the same format, where possible, as displayed, ex. (TRP). 16 5. 2 How to use the push-buttons DAMPENING SIGN SUB FUNCTION MAIN FUNCTION PAGE CLEAR 5. 2. 1 PAGE MINUS PLUS SET The PAGE button is used to move the cursor when in edit mode. A press on PAGE moves the cursor in a circular pattern, one step to the right for every press. A press on PAGE and MINUS together, back steps cursor to the preceding step. When unlocked, the digits are "active" (flashes) and can be edited by pressing MINUS, PLUS and PAGE as required. When finished editing, lock the digit by another press on SET. 17 5. 2. 5 Clear / cancel / reset A press on CLEAR, clear digits, cancel alarms or resets the counters. 5. 2. 6 Calibration To access calibration mode, press and hold SET more than 2 seconds. 2 sec To return to main-function mode, press SET when the text return (RET) is shown. 5. 2. 7 Lighting The instrument uses red back lighting for the display and the 5 pushbuttons. The lighting can be set at 4 different levels. 2 sec To quick access the light control, press and hold PAGE for more than 2 seconds. The flashing text (Lit OFF) will be displayed and the display will be lit momentarily. To select between the 4 light levels, Press PLUS: LOW, MED, MAX and OFF. The selected light level will be copied to all FI-30 instruments connected to the system. [. . . ] Nexus Network data bus ID numbers for each instrument (displayed at power up). 8. 2. 1 General In most cases, the reason for faults in electronic equipment is the installation or poor connections. Therefore, always first check that: · · · · · · · · · Installation and connection is made per instructions for instrument and transducers, (see 2). Two instruments do not have the same ID number, (see 4. 2). 24 8. 2. 2 Fault - action 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FI-302




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO FI-302 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.