User manual FURUNO FCV-620

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO FCV-620. We hope that this FURUNO FCV-620 user guide will be useful to you.


FURUNO FCV-620 : Download the complete user guide (6590 Ko)

You may also download the following manuals related to this product:

   FURUNO FCV-620 OPERATORS MANUAL (20351 ko)

Manual abstract: user guide FURUNO FCV-620

Detailed instructions for use are in the User's Guide.

[. . . ] IMPORTANT NOTICE · No part of this manual may be copied or reproduced without written permission. · If this manual is lost or worn, contact your dealer about replacement. · The contents of this manual and equipment specifications are subject to change without notice. · The example screens (or illustrations) shown in this manual may not match the screens you see on your display. [. . . ] Note that this function is inoperative with single frequency, nav data mode or A-Scope display. Choose Window Size in the Display menu and press the ENTER key. G:AF R:A 0 50/200 0. 0 1/1 0 20 20 Dividing line 40 40 / : Adjust [ENTER] : Set [MENU] : Cancel 60 60 49. 6 m 80 80 Display menu Depth Size: Choose the font size of the depth indication (Small, Medium or Large). Zoom Marker: Turn the zoom marker on or off (on the single frequency display) when the bottom lock display, the bottom zoom display or the marker zoom display is selected. The temperature scale range is 16° (°F) in "Narrow", 32° (°F) in "Wide". Requires water temperature data. G:AF R:A 50k 1/1 0 Window size setting window 2. Battery: Turn the battery voltage indication (appears at the top right corner on the screen) on or off. Palette: Change the background color of the screen in five colors: white, blue, black, gray and night. Header Info: Turn the data area indication (appears at the top on the screen) on or off. G:AF R:A 50/200 1/1 56 48 40 32 Temperature 20 Graph Temperature Scale 40 60 Data area 24 49. 6 m 80 Temperature graph 18 1. OPERATION Data menu This menu mainly sets up how to display data input by external equipment. Data Go to WPT WPT List Nav Display1 Nav Display2 Bearing Wind Spd/Dir Trip Source Temp Source Speed Source Trip Reset Odo Reset // [ENTER] [MENU] / : Off : Off : Off : True : True : Own : Own : Own Temp Source: Choose source of water temperature input; Off, Own (temperature sensor connected to the FCV-620/585) or NMEA (speed data from external equipment). Speed Source: Choose source of speed input; Off, Own (speed sensor connected to the FCV620/585) or NMEA (speed data from external equipment). Beeps are generated while the odometer is being reset. : Select : Enter : Back Data menu Nav Display 1, 2: Data for speed (SOG), speed (STW), depth, range, bearing, position, wind, heading, course, barom press, water temperature, time to go, trip meter, odometer or XTE can be displayed on the left top of the screen. Appropriate sensor is required to display data other than depth. 15. 5 kt 82. 6 Data box Bearing: Ship's course and heading may be displayed in true or magnetic bearing. Magnetic bearing is true bearing plus (or minus) earth's magnetic deviation. Wind Spd/Dir: Choose the wind speed and direction reference from true and apparent. Apparent: The direction (in relation to ship's heading) and speed of the wind as it appears to those on board, relative to the speed and direction of the boat; combination of the true wind and the boat's movement. True: The speed and direction (in relation to ship's heading) of the wind felt or measured when stationary. Trip Source: Choose speed source for the trip distance indication: Off, Own (speed sensor connected to the FCV-620/585) or NMEA (speed data from external equipment). 19 2. 2. 1 SYSTEM MENU Displaying System Sub Menu Range 1 - Range 8: Set range of each of the eight ranges (selectable range: 7 to 2, 500 ft). Note that all default ranges are restored whenever the depth unit is changed. Zoom Range: Choose the range to zoom in the bottom zoom and marker zoom modes. B/L Range: Choose the expansion width for the bottom lock display from 10 to 30 feet. The System menu mainly consists of items which once set do not require frequent adjustment. The list of sub menus appears below System. Menu Sounder Display Alarm Data System Range Key Lang Units NMEA Calib Demo Tests Reset 2. 3 Key Menu Key FUNC Key Key Beep // [ENTER] [MENU] / : Pic. Refer to chapter 3. Key menu FUNC Key: Register the item for instant display of a user-defined options window. [. . . ] Data is transducer cableoutput at two-second intervals. Output data sentences Sentence DBT (Ver. 3. 0) MTW* VHW* TLL* Meaning Depth below transducer Depth Water temperature Water speed and heading Target position, output by MARK key. Input data sentences Sentence BWC GGA GLL HDG HDT MDA MTW Meaning Bearing and distance to waypoint. Water temperature. *= Available with connection of optional sensors/navaid 36 4. Use or to choose NMEA under System menu and press the ENTER key. NMEA NMEA0183 NMEA Port NMEA Output WAAS Setup TLL Output // [ENTER] [MENU] / : Ver 2. 0 : In/Out : Off : Off : TLL WAAS Setup Choose how to use the WAAS signal when connecting with a WAAS receiver, for example GP-320B. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FCV-620




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO FCV-620 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.