User manual FURUNO FCV-1200L

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO FCV-1200L. We hope that this FURUNO FCV-1200L user guide will be useful to you.


FURUNO FCV-1200L : Download the complete user guide (1578 Ko)

You may also download the following manuals related to this product:

   FURUNO FCV-1200L OPERATORS MANUAL (1587 ko)

Manual abstract: user guide FURUNO FCV-1200L

Detailed instructions for use are in the User's Guide.

[. . . ] Back COLOR LCD SOUNDER FCV-1200L/1200LM Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : Telefax : 0798-65-2111 0798-65-4200 All rights reserved. Printed in Japan FIRST EDITION : APR. OME-23650 ( DAMI ) FCV-1200L/LM *00080900501* *00080900501* *00080900501* *OME23650N00* *OME23650N00* *OME23650N00* SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Immediately turn off the power at the switchboard if water leaks into the equipment or something is dropped in the equipment. Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire. [. . . ] When the bottom is rough, the bottom echo may be displayed too thinly if the display shift setting is "1/4. ". In this case use the "1/2" setting to display the bottom echo clearly. 1/5 1/3 3/4 Display range is shifted downward when the bottom echo comes to the location 1/5 of the display When the bottom echo comes to the bottom of the screen, the display range is shifted downward. Automatic shift (1/2) DISPLAY DATA Selects the data to display at the left top corner of the screen among OFF, L/L*, TD*, TIMER (Elapsed time from the moment when the [MARKER/TLL] key is pressed), GAIN**, R/B* (range and bearing to the waypoint) and COURSE*. **: The gain setting shown on the display may not agree exactly with GAIN controller position. When you change the gain setting and then return correctly, using of the setting shown on the display is recommended. 2-5 SCROLL TIME Turns the display scroll time on/off. Scroll time displays, at the screen bottom, the amount of time a scan line stays on the screen as it passes from one side of the screen to the other. Time varies with the range and picture advance speed. SMOOTHING-1 This setting can only be changed when the picture advance speed is set to 1/16, 1/8, 1/4, 1/2 or 1/1. Adjust the setting when echoes appear "spotty. " SMOOTHING-2 This setting can only be changed when the picture advance speed is set to 2/1, 3/1 or 4/1. Select ON when rough echoes appear. 2-6 2. 3 [-], [+], [ ALM Menu ] or [ ] key. Sets the alarms; BOTTOM, FISH and TEMP (temperature). To silence the alarm beep, press the BOTTOM ALARM When your ship comes in the area of the selected depth, the beep sounds and the indication BTM flashes at the top right corner to draw your attention. FISH ALARM FISH ALARM: Fish echoes of yellow or stronger colors (default setting) trigger the alarm. BTM-FISH ALARM: When fish echoes come in the area which you set above the bottom, the beep sounds and the indication FISH flashes at the top right corner of the screen. (Available mode: bottom lock, discrim 1/2, discrim 1/3) TEMP ALARM Selects temperature range which triggers temperature alarm. Alarm is activated (beep sounds and the indication TEMP appears at the top right corner of the screen) when water temperature is above (UP) or below (DOWN) the preset value. 3. Setting the alarm Rotate the [FUNCTION] switch fully clockwise to select MENU. Press the [-] or [+] key to select ALM to display the ALM menu. 2-7 DISP ALM TX/RX USER-1/2 SYSTEM BOTTOM ALARM : OFF ALARM DEPTH : 0 ft * ALARM ZONE : 10 ft FISH ALARM ALARM DEPTH ALARM ZONE ALARM LEVEL : OFF : 0 ft : 10 ft * : MID TEMP ALARM : OFF TEMP LIMIT : 65. 0°F(20~95) * ALARM ZONE : 1. 0°F Menu for alarm setting. [-/+]: Change set, [EXIT (knob)]: Exit *: The setting is not available when ALARM is OFF. ALM (Alarm) menu 4. Press the [-] or [+] key to show the alarm setting window. OFF ON OFF FISH BTM-FISH OFF WITHIN RANGE OUT OF RANGE Bottom alarm Fish alarm Temp alarm Alarm setting window 6. Press the [ ] key twice to select ALARM DEPTH (TEMP LIMIT for temp alarm). Press the [-] or [+] key to show the alarm setting window. 0 ft Starting depth setting window (ex. For BOTTOM ALARM and FISH ALARM, press the [-] or [+] key to set the starting point of alarm zone. Alarm marker appears (Depth alarm: green, Fish alarm: white). 2-8 Selected alarm (flashing) BTM Start line Alarm area Alarm marker Bottom alarm (green): right side 12. 5ft Fish alarm (white): right side Bottom-fish alarm (white): left side (vertical screen division) right side (horizontal screen division) Setting of alarm zone (ex. Press the [-] or [+] key to show the alarm zone setting window. 10 ft Alarm zone setting window (ex. Press the [-] or [+] key to set the alarm zone. For depth alarm and temp alarm, go to step 16. Press the [-] or [+] key to show the level setting window. MIN MID MAX Level setting window 15. [. . . ] Select INTERNAL at HF/LF XDCR CONNECT on ES/DRAFT SETTING menu. AP-6 (two split screen) (half) (1:2) H N O R M A L HIGH NORMAL L N O R M A L LOW NORMAL H Z O O M L Z O O M HIGH ZOOM LOW ZOOM [HF]: Zm/Nor ET T/S R Z O O M ET T/S R N O R M A L [LF]: Zm/Nor ETR/ TELESOUNDER NORMAL ETR/ TELESOUNDER ZOOM L N O R M A L H N O R M A L [LF]+[HF] HIGH NORMAL LOW NORMAL *[Ex]: Zm/Nor ET T/S R N O R M A L H N O R M A L HIGH NORMAL ETR/ TELESOUNDER NORMAL ET T/S R N O R M A L L N O R M A L LOW NORMAL ETR/ TELESOUNDER NORMAL *[Ex]+[HF] *[Ex]+[LF] L Z O O M H Z O O M HIGH ZOOM H N O R M A L M I X N O R [HF]+[Mix] MIX NORMAL LOW ZOOM HIGH NORMAL [LF]:Zm+[HF]:Zm L N O R M A L M I X N O R [LF]+[Mix] MIX NORMAL H H S U B N O R M A L HIGH NORMAL LOW NORMAL HIGH SUB [H]sub+[HF] L L S U B N O R M A L LOW NORMAL Tbe dashed line shows position of dividing line for vertical (1:2) split screen. LOW SUB [L]sub+[LF] *: For FCV-1200L with EXIF assy. Select INTERNAL at HF/LF XDCR CONNECT on ES/DRAFT SETTING menu. AP-7 (three split screen) L N O R M A L H Z O O M N O R M A L H HIGH NORMAL HIGH ZOOM LOW NORMAL L Z O O M L N O R M A L H N O R M A L HIGH NORMAL LOW NORMAL LOW ZOOM [LF]+[HF]: Zm/Nor ET T/S R N O R M A L [LF]: Zm/Nor+[HF] ET T/S R N O R M A L H H Z O O M N O R M A L HIGH NORMAL HIGH ZOOM ETR/ TELESOUNDER NORMAL L L Z O O M N O R M A L LOW NORMAL LOW ZOOM ETR/ TELESOUNDER NORMAL *[Ex]+[HF]: Zm/Nor E TE T T/S T/S R R Z O O M N O R M A L *[Ex]+[LF]: Zm/Nor H N O R M A L HIGH NORMAL ETR/ TELESOUNDER NORMAL ETR/ TELESOUNDER ZOOM E TE T T/S T/S R R Z O O M N O R M A L L N O R M A L LOW NORMAL ETR/ TELESOUNDER NORMAL ETR/ TELESOUNDER ZOOM *[EX]:Zm/Nor+[HF] *[EX]:Zm/Nor+[LF] ET T/S R N O R M A L L N O R M A L H N O R M A L HIGH NORMAL LOW NORMAL ETR/ TELESOUNDER NORMAL L N O R M A L H N O R M A L M I X N O R MIX NORMAL HIGH NORMAL LOW NORMAL *[Ex]+[LF]+[HF] [LF]+[HF]+[Mix] L N O R M A L H S U B H N O R M A L HIGH NORMAL HIGH SUB LOW NORMAL L L S U B N O R M A L H N O R M A L HIGH NORMAL LOW NORMAL LOW SUB [LF]+[H]sub+[HF] [L]sub+[LF]+[HF] *: For FCV-1200L with EXIF assy. Select INTERNAL at HF/LF XDCR CONNECT on ES/DRAFT SETTING menu. (four split screen) LOW NOR HIGH NOR LOW ZOOM HIGH ZOOM [LF]: Zm/Nor+[HF]: Zm/Nor AP-8 APPENDIX 3 menu. DISPLAY DIVISION The display is arranged as shown below through DISP DIVISION on the SYSTEM SETTING LF or HF DUAL ZOOM NORMAL LOW/HIGH LOW HIGH ZOOM LOW/ HIGH SONDE WATER TEMP "ON" S O N D E LOW/ HIGH S O N D E LOW HIGH S O N D E Z O O M H I G H / L O W A A-SCOPE "ON" LOW/HIGH S C O P E LOW HIGH A S C O P E Z O O M H I G H / L O W A S C O P E The width of the sonde temperature display may be set to 1/4 or 1/2 the screen size. When Sonde temperature display is set to 1/2, and the A-scope is turned on, the width of the sonde temperature display becomes 1/4 automatically. AP-9 LF or HF DUAL ZOOM HIGH NORMAL LOW/HIGH LOW LOW/HIGH ZOOM SONDE WATER TEMP "ON" S O N D E LOW/ HIGH S O N D E HIGH LOW S O N D E LOW/ HIGH ZOOM A A-SCOPE "ON" LOW/ HIGH S C O P E HIGH A S C O P E LOW/ HIGH A S C O P E LOW ZOOM The width of the sonde temperature display may be set to 1/4 or 1/2 the screen size. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FCV-1200L




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO FCV-1200L will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.