User manual FURUNO ETR-30N OPERATORS MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO ETR-30N. We hope that this FURUNO ETR-30N user guide will be useful to you.


FURUNO ETR-30N OPERATORS MANUAL: Download the complete user guide (663 Ko)

Manual abstract: user guide FURUNO ETR-30NOPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Back NETWORK SOUNDER ETR-30N SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment unless totally familiar with electrical circuits and service manual. Only qualified personnel should work inside the equipment. WARNING Install the transducer tank according to the installation instructions. Failure to install the tank correctly may result in water leakage and damage to the ship's hull. Turn off the power at the switchboard before beginning the installation. Do not install the equipment where it may get wet from rain or water splash. [. . . ] *3 = MJ-A6SPF0014-010/050/100/200/300 (1, 5, 10, 20, 30 m) *4 = MJ-A6SRMD/TM11AP8-005 *5 = Connect to NET KP to get best performance. *6 = If an external KP (Keying Pulse) is required, contact a FURUNO dealer. Connection of multiple network sounders 5 2. 2 Settings for Single Network Sounder WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. 2. 2. 1 Internal settings Set the tap inside the network sounder to match transducer output power. Remove the cover of the network sounder. TAP H ABCDE ABCDE TAP L Network sounder ETR-30N, top view, cover removed 3. Using a pincers, set jumper block of TAP H (High) referring to the transducer label on the cover. When the NavNet display unit is powered you can confirm setting (see page 10). Note 1: The transducer model recorded on the label is in the unit's memory. Therefore, you can set transducer type following "Transducer connected to the ETR-30N is programmed in the ETR-30N" (page 9. ) Note 2: To connect other make of transducer contact your FURUNO dealer for details. Confirm that the HOST NAME control is in the "0" position. J9 . . . . . . . . . . J2 6 HOST NAME Control Sets host name. FURUNO NETWORK SOUNDER ETR-30N HOST NAME 45 6 3 7 2 8 1 09 DEFAULT TX/STBY POWER I ON O OFF POWER switch Turns power On and off. LED lamp The lamp flashes when the NavNet display unit is powered and communicating with the network sounder. ETR-30N 7. Confirm that the LED lamp flashes. 2. 2. 2 Sounder source setting 1. Press the [POWER/BRILL] key on the NavNet series unit while pressing and holding down the [MENU] key. Release the [MENU] key when the message "STARTING INSTALLATION MODE" appears. Press the INSTALLATION SETUP soft key. RADAR MENU SYSTEM CONFIG INSTALL SETUP RADAR DISPLAY SETUP RADAR RANGE SETUP ARP SETUP FUNCTION KEY SETUP SYSTEM CONFIGURATION GENERAL SETUP NAV OPTION SYSTEM SETUP INSTALLATION SETUP RETURN NETWORK SETUP RADAR SETUP NETWORK SOUNDER SETUP NETWORK SETUP FOR AUX# RETURN Radar menu System configuration menu Install setup menu # =Shown on Model 1833C only How to access the installation setup menu (example: radar NavNet unit) 7 Note: The very first time the system is powered you are asked if you want to start the simulation mode, which provides simulated operation of the equipment. Press the [CLEAR] key to start normal operation to set up the transducer. For further details about the simulation mode, see your NavNet series operator's manual. START SIMULATION MODE?Press the NETWORK SETUP soft key. 172. 031. 092. 001 RADAR________ RADAR________ ______________ ______________ ______________ SOUNDER SOURCE SOUNDER AUX* WFAX SUBNET MASK 255. 255. 000. 000 GATEWAY ADDRESS 000. 000. 000. 000 OFFSET PORT NUMBER 10000 IP ADDRESS HOST NAME RADAR SOURCE CHART SOURCE NETWORK SETUP EDIT RETURN * = Model 1833C only. Network setup menu 7. Confirm that the "SOUNDER SOURCE" is SOUNDER. 8 2. 2. 3 Transducer setup CAUTION Enter transducer setting correctly. A wrong transducer setting can damage the transducer. Transducer connected to the ETR-30N is programmed in the ETR-30N 1. At the installation menu, press the NETWORK SOUNDER SETUP soft key. IP ADDRESS HOST NAME 172. 031. 092. 001 SOUNDER____ SNDR SETUP EDIT Note: Do not change IP address or host name from this display. FREQ SETUP RETURN Sounder setup 2. (If the FREQ SETUP soft key is not shown, check that the ETR-30N is powered. ) Confirm that sounder source (shown on the network setup menu, see page 8) and the HOST NAME control setting are the same. HOST NAME Control Setting 0 (Default Setting) 1 2 3 4 5 6 7 8 9 Host Name SOUNDER SOUNDER1 SOUNDER2 SOUNDER3 SOUNDER4 SOUNDER5 SOUNDER6 SOUNDER7 SOUNDER8 SOUNDER9 9 TRANSDUCER SETUP HIGH FREQUENCY MANUAL --kHz (0kW TAP:-) --kHz (0kW TAP:-) SNDR SETUP EDIT LOW FREQUENCY TAP SETTINGS MUST BE MADE ON ETR UNIT. AFTER SETUP, DISPLAY MUST BE TURNED OFF & ON TO ALLOW NEW SETTINGS TO TAKE EFFECT. RETURN Frequency setup screen 3. [. . . ] The option "S" means the ship's speed dependent mode, where the PRR automatically changes with ship's speed (requires speed input). Use the trackball or cursor pad to select pulse repetition rate desired. Press the ENTER soft key followed by the [MENU] key to close the menu. Sounder system setup menu Menu items for adjustment of STC and frequencies and selection of fishing objective have been added to the SOUNDER SYSTEM SETUP menu. Press the [MENU] key, choose SOUNDER SYSTEM SETUP menu and then press the NEXT PAGE soft key. STC - HF STC - LF FREQ. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO ETR-30N




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO ETR-30N will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.