User manual FURUNO ETR-10N OPERATORS MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO ETR-10N. We hope that this FURUNO ETR-10N user guide will be useful to you.


FURUNO ETR-10N OPERATORS MANUAL: Download the complete user guide (703 Ko)

Manual abstract: user guide FURUNO ETR-10NOPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Do not use chemical cleaners such as alcohol, acetone and benzine to clean the equipment. i i WARNING LABEL A warning label is attached to the units shown right. If a label is missing or is illegible, contacta FURUNO dealer or agent about replacement. WARNING To avoid electrical shock, do not remove cover. No user-serviceable parts inside. Name: Warning Label (1) Type: 86-003-1011 Code No. : 100-236-230 MAIN DISPLAY UNIT DS-500 Warning label PROCESSOR UNIT DS-510, DS-511 TRANSCEIVER UNIT DS-520 ii iii TABLE OF CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Power consumption Dual range system ø200 mm 5 VA approx. Specifications of DS-501 Control Box (option) 1. Illumination Flush mount 200 mW max LED Specifications of DS-730 Distance Indicator (option) 1. Power consumption ËËËËË. Ë nm LCD with dimmer 2. 5 VA approx. Specifications of DS-760 Series Analog Display (option) 1. Power consumption -10 to 30 kt DS-761/762: ø200 mm DS-763: ø100 mm 5 VA approx. 4 SYSTEM CONFIGURATION MAIN DISPLAY UNIT DS-50 CONTROL BOX DS-501 (option) G W A T kt m/s AL ft fa nm SIGNAL cable POWER cable DIGITAL DISPLAY DS-350/351 (option) ANALOG INDICATOR RANGE DS-381/382 SWITCH BOX DS-389, HF-22A MF-22A PROCESSOR UNIT DS-511/510 DISTANCE INDICATOR DS-730 (option) DIMMER MF-22L SHIP'S MAINS 115/230 VAC, 50/60 Hz, 1¿ DISTRIBUTION BOX DS-370 (option) JUNCTION BOX DS-360 (option) DISTANCE RUN INDICATOR DIGITAL DISPLAY ANALOG DISPLAY TRANSCEIVER UNIT DS-520 Note: When Processor Unit DS-510 is used Transceiver Unit is incorporated in the DS-510. JUNCTION BOX CI-630 (option) TRANSDUCER TANK DS-531 or GATE VALVE DS-532 TRANSDUCER DS-530 TRANSDUCER TANK DS-331 / TRANSDUCER DS-330 or GATE VALVE for TRANSDUCER DS-335 5 OPERATION Controls and Indications on the Main Display Unit Port or starboard speed Port and starboard direction indicators FURUNO FURUNO DOPPLER SONAR DS-50 Fore or aft speed Tracking mode indicator Ground Water Automatic Fore and aft direction indicators G W A Distance Keel Clearance T kt m/s Test mode indicator Unit of speed (knot or meters/second) Speed alarm Unit of keel clearance or distance run: ft (feet), fa (fathoms), or nm (nautical miles) DIMMER controls Adjust brilliance. AL ft fa nm DIMMER MODE selector Selects tracking mode. MODE Distance Keel Clearance Distance/Keel Clearance selector Displays distance run or keel clearance. SET and arrow keys POWER switch Kt/ m/s selector Set distance run. Selects unit of speed measurement. Note: Performance may be affected by air bubbles, interference and other factors. v v Push here to open lid. 6 v v Control description Main controls MODE selector Selects tracking mode among ground, water and automatic. Each time the key is pressed the tracking mode changes in the sequence of ground, water and automatic. Current tracking mode is denoted by the tracking mode lamps. Distance/Keel Displays distance run or depth below keel at each pressing. Clearance selector "Distance" or "Keel Clearance" lights to show current selection. DIMMER controls Adjust panel brilliance. Controls in compartment Distance Set Kt / m/s SET Kt/ m/s selector SET key Arrow keys POWER switch Selects the unit of speed measurement; knots or meters/second. Turns power on and off. 7 v t s w POWER Turning on the Power, Adjusting Panel Brilliance 1. The equipment is tested in the sequence below: 1) Communications test between main display unit and the processor unit is conducted. Three zeroes blink about 30 s. FURUNO FURUNO DOPPLER SONAR DS-50 G W A Distance Keel Clearance T kt m/s AL ft fa nm DIMMER Distance Keel Clearance Zeroes blink for about 30 s. MODE Power switch behind the cover 2) Testing of main display and processor unit begins. Memory, LEDs and buzzer are tested in order, each tested eight times consecutively. Open the lid at the bottom of the display unit and press the [SET] key. The display should look like the illustration below, with the highest digit of distance run blinking. 1 2 3 0 0 nm: Before pressing [SET] key 0 0 1 2 3 0 0 nm: After pressing [SET] key Blinking 2. Repeat steps 2 and 3 to change other digits. Note 1: Distance run can be reset to zero by entering all zeroes. Note 2: To restore previous distance run setting, do not operate arrow keys or [SET] key for more than 10 seconds. When this is done the distance run indication stops blinking and then the previous setting is restored. Note that if the ship is moving at this time the distance run indication will change. Press the [SET] key. 10 System Settings The system settings do not require frequent adjustment. The table below shows setting range and default setting for each parameter. No. 1 2 3 4 5 6 7 8 9 10 Item Ground speed offset Water speed offset Transducer installation offset Trim angle offset Heel angle offset Speed averaging Reference water speed depth External KP1 distance External KP2 distance Setting Range -12. 8 to+12. 7%, 0. 1% steps -12. 8 to +12. 7%, 0. 1% steps -12. 8 to +12. 7°, 0. 1° steps -12. 8 to +12. 7°, 0. 1° steps -12. 8 to +12. 7°, 0. 1° steps 15, 30, 60, 90 sec 2. 0 to 25. 0 m, 1 m steps 0. 0 to +300. 0 m, 0. 1 m steps 0. 0 to +300. 0 m, 0. 1 m steps Default Setting 0% 0% 0° 0. 0° 0. 0° 15 sec 2m 0. 0 0. 0 m Unit of keel clearance measurement m/ft/fa Note: The above settings are retained with an internal battery when the power is off. 11 Setting procedure 1. [. . . ] In the processor unit of the DS-50, difference of "fo + fd" and "fo - fd" are computed to extract only the Doppler shift factor "fd". (fo+fd) -(fo-fd) = 2fd Since the 'fd' is theoretically given by fd = 2Vcos x fo/C (C: Sound velocity in water) and fo, C and are known, V can be calculated if the "fd" is given. Note that the sound velocity in water changes with water temperature and water pressure but the change by water temperature is automatically compensated for by using temperature sensor. 18 DIGITAL INTERFACE IEC 61162-1 EDITION 2 Output sentences of channel 1, 2 (NMEA/CIF 1, NMEA/CIF 2) VBW, VTG, VLW, VHW. Heading data in VTG and VHW is "null. ") Transmission interval 1 s for any sentence Data transmission Data is transmitted in serial asynchronous form in accordance with the standard referenced in 2. 1 of IEC 61162-1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO ETR-10N




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO ETR-10N will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.