User manual FURUNO DS-80 OPERATORS MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO DS-80. We hope that this FURUNO DS-80 user guide will be useful to you.


FURUNO DS-80 OPERATORS MANUAL: Download the complete user guide (691 Ko)

Manual abstract: user guide FURUNO DS-80OPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] DOPPLER SPEED LOG Marine Speed and Distance Measuring Equipment (SDME) DS-80 Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : Telefax : 0798-65-2111 0798-65-4200 All rights reserved. Printed in Japan FIRST EDITION : FEB. OME-72470 ( DAMI ) DS-80 *00080889601* *00080889601* *00080889601* *OME72470M10* *OME72470M10* *OME72470M1* SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Immediately turn off the power at the switchboard if water leaks into the equipment or an object is dropped into the equipment. Fire or electrical shock can result if the liquid spills into the equipment. [. . . ] Press the Omnipad at or to select the menu item desired and press the [ENT] key. For example select RESET. DISTANCE RUN DISPLAY DATA DISPLAY CONTACT CLOSURE RESET OFF SET OFF ON The operator may adjust and reset the distance run indication and select display method. 1. 6. 1 Selecting display method The default setting provides for independent display and adjustment of the distance run indication on all displays (display unit, Digital Indicator, distance indicator). To show the same distance run indication on all displays do the following: 1. Press the Omnipad at or to select the menu option desired and press the [ENT] key. 7 MENU DISTANCE RUN DISPLAY DEMO SYSTEM MENU SYSTEM MENU2 The cursor circumscribes the leftmost digit of the distance run figure. DISTANCE RUN DISPLAY DATA DISPLAY CONTACT CLOSURE RESET OFF SET 000000. 00nm ENT SET 2. Press the Omnipad at to select DISTANCE RUN DISPLAY and press the [ENT] key. DISTANCE RUN DISPLAY DATA DISPLAY CONTACT CLOSURE RESET OFF SET 0. 00nm ENT SET Cursor 4. Press the [ENT] key followed by pressing the [MENU] key twice to conclude your selection and close the menu. 3. Select DATA DISPLAY and press the [ENT] key. DISTANCE RUN DISPLAY DATA DISPLAY CONTACT CLOSURE RESET IEC61162(VLW) OFF SET CONTACT CLOSURE 0 . 0 0 nm ENT SET 1. 6. 3 Resetting distance run to zero Distance run can be reset to zero when the menu item DATA DISPLAY is selected to CONTACT CLOSURE. It may also be reset to zero only at the display unit when IEC 61162(VLW) is selected. Select RESET and press the [ENT] key. DISTANCE RUN DISPLAY DATA DISPLAY CONTACT CLOSURE RESET OFF SET OFF ON 4. Press the [MENU] key twice to close the menu. 1. 6. 2 Adjusting distance run Distance run can be changed when the menu item DATA DISPLAY is selected to CONTACT CLOSURE. It may also be changed only at the display unit when IEC 61162(VLW) is selected. Press the [ENT] key to finish and press the [MENU] key twice to close the menu. Press the [MENU] key twice to close the menu. 1. 7 System Setting 1. 7. 3 Speed offset (calibration) Calibration of any speed log is necessary through the sea trials during the commissioning tests. Us the resultant data to calculate speed offset and enter it as below. Select SPEED OFFSET and press the [ENT] key. SYSTEM MENU SHIP SPEED AVG 30 SEC SPEED OFFSET +0. 0% TRACK DEPTH 2. 0 m XDR OFFSET +00° SPD DATA SELECT DOPPLER ENT: SET The system setting provides the fundamental parameters for intended performance of the DS-80. 1. 7. 1 Displaying the system menu 1. Select SYSTEM MENU and press the [ENT] key. SYSTEM MENU SHIP SPEED AVG 15 SEC SPEED OFFSET +0. 0% TRACK DEPTH 2. 0 m XDR OFFSET +00° SPD DATA SELECT DOPPLER ENT: SET 1. 7. 2 Ship speed average Wind and currents affect ship's speed, and speed data is averaged over the time period set on this menu. Select SHIP SPEED AVG and press the [ENT] key. 15 SEC 30 SEC 45 SEC 60 SEC 3. Select the digit to change with and change the value with the Omnipad. Press the [MENU] key twice to close the menu. 1. 7. 4 Tracking depth Doppler shift measuring depth in the DS-80 is 2 m at default. If the speed readout is unstable due to air bubbles near the ship's hull, increase or decrease the track depth to stabilize the readout. Open the SYSTEM MENU. 9 SYSTEM MENU SHIP SPEED AVG 30 SEC SPEED OFFSET +0. 0% TRACK DEPTH 2. 0 m XDR OFFSET +00° SPD DATA SELECT DOPPLER ENT: SET 1. 7. 6 Speed data selection When the DS-80 fails to work as an SDME, the display unit can be used as a monitor display tool for a GPS speed or other equipment measuring the ship's speed. [. . . ] The ROM, RAM and SIO (if special connector is used) are checked for proper operation and the results shown as OK or NG (No Good). "PUSH KEY" is highlighted, prompting you to check the controls. The name of the activated control appears on screen if it is operating normally. The equipment automatically checks the LCD, displaying the following in order. <LCD CHECK> ALL ON 2 SEC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO DS-80




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO DS-80 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.