User manual FURUNO CH-250

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FURUNO CH-250. We hope that this FURUNO CH-250 user guide will be useful to you.


FURUNO CH-250 : Download the complete user guide (1253 Ko)

You may also download the following manuals related to this product:

   FURUNO CH-250 (1489 ko)
   FURUNO CH-250 OPERATORS MANUAL (1514 ko)

Manual abstract: user guide FURUNO CH-250

Detailed instructions for use are in the User's Guide.

[. . . ] Back COLOR LCD SEARCHLIGHT SONAR CH-250 C Your Local Agent/Dealer 9-52, Ashihara -cho, Nishinomiya, Japan Telephone: Telefax: 0 7 9 8 - 6 5 - 2111 0798-65-4200 All rights reserved. Printed in Japan FIRST EDITION K2 : : M A R. O M E -1 3 1 6 0 C H -2 5 0 SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Immediately turn off the power at the switchboard if water leaks into the equipment or something is dropped in the equipment. Immediately turn off the power at the switchboard if the equipment is emitting smoke or fire. [. . . ] The length of the picture displayed in the history display is equal to about four full circle pictures. Thus the history display enables you to observe the history of fish movement and distribution. It is also useful for detecting bottom fish, reefs and sunken vessels. The history display cannot be adjusted. 2-28 Horizontal/video plotter display Press the key to display the horizontal/video plotter display. Tilt angle Cursor position data 18 15 B154° + Own ship marker Range Tilt angle indicator R 40 m T 40° 25 30 Interference rej. 213' W CSE 357° SPD 9. 9 kt Position in latitude*, longitude* Course*, speed* Sonar range marker Track* Event marker Cursor 15 B 195° Event marker data * Requires appropriate sensor. Track* 500 Event marker (Entered from horizontal mode) Scale Horizontal Display Video Plotter Display Figure 2-28 Horizontal/Video Plotter display The horizontal display appears in the main window; the video plotter display, which traces ship's track on the display, in the sub window. Compared to the horizontal display the video plotter's range is much longer. For example, an event marker entered on the horizontal display disappears from that display when it goes out of the current range. However, it remains on the video plotter display for a much longer time when a long range scale is used. This can be useful when you want to return to the location denoted with an event marker. The video plotter scale can be changed (setting range: 500-5, 000 meters) with "TRACK DISP" on the RANGE-SONAR MODE menu. The video plotter display cannot be adjusted. 2-29 Horizontal/strata display Press the key to display the horizontal/strata display. Tilt angle Cursor position data 12 10 B133° + Own ship marker Range Tilt angle indicator R 40 m T 40° 25 30 Interference rej. ON Target lock indicator Transducer status indicator Position in latitude*, longitude* Course*, speed* Number of lines increases by one with each train. 213' W CSE 357° SPD 9. 9 kt PORT STBD Color bar for strata display Cursor -90° 0° Heading +90° Horizontal Display (main display) Strata Display (sub window) Figure 2-29 Horizontal/strata display The horizontal display appears in the main window; the strata display in the sub window. This is useful in bottom trawling to avoid projections which may damage the net. Coverage for the horizontal mode is 360° picture, and for the strata display it is maximum 90° from port to 90° starboard. The strata display may be adjusted with the [RANGE] and [SECTOR] controls. The message MAIN WINDOW CONTROLLABLE or SUB WINDOW CONTROLLABLE appears with each pressing of the key. A red cursor appears in the sub window when it can be controlled. 2-30 Color bar for the strata display The depth of the bottom echo in all directions is displayed in the sub window, in the colors set by the color bar for the strata display. Strongest color Weakest color -90° -18° -12° -6° 0° 6° 12° 18° 90° Color bar for strata display The undulation of the bottom echo in all directions is shown by the colors on the color bar for the strata display. The position of the weakest echo can be changed with the [RANGE] control, and the width of each color on the color bar for the strata display with the [SECTOR] control. Use the [SECTOR] control to adjust width of each color. Weakest color Use the [RANGE] control to move the location of the weakest echo color. Note: TILT, TRAIN, FULL/HALF, FAST SCAN, R/B, EVENT, TARGET, CUSTOM MODE controls may only be operated from the main window. When you attempt to operate them from the sub window the message "SELECT MAIN WINDOW. " appears for about four seconds. Flat bottom and strata display Each layer on the strata display is equal to one train on the horizontal display. [. . . ] 1. 0 kHz (external speaker required) 5 points Low level enhanced echo disappeared Strong echo indicated as expanded to range direction Vector estimated point after 10 seconds to 6 min. (menu setting) 2. 10 Event Mark 2. 11 Hue 2. 12 Red Color Enhancement 2. 13 Arrival Mark 2. 14 Target Lock (three function selected on menu) Scanning Reverse Location Search Echo Search Scanning orientation changed by pressing key Auto-search for marker setting location Auto-search for signal level in a search zone, or manual echo search 3 3. 1 3. 2 3. 3 3. 4 TRANSCEIVER UNIT Frequency Output Power Output Pulse Length TVG 60/ 88/ 150 kHz, Auto-setting according to Hull Unit Specs. 0. 8-1. 2 kW (due to frequency), power reduction function available 0. 2 to 20. 0 ms, according to range Level: 100 dB max. , Distance: 1000 m 4 4. 1 4. 2 4. 3 4. 4 HULL UNIT Transducer Travel Raise/lower Time Ship's Bow Setting Horizontal Mode Control Scanning Angle Scanning Center Scanning Step Angle Elevation Angle Auto Tilt setting 6° to 360°, 24° step 6° steps, 360° setting available Normal: 6°, High speed: 12° +5° to 90°, 1° step ±2° to ±10° 400 mm or 250 mm 30 s at 400 mm travel Setting offset on menu at installation within ±30° 4. 5 Time to Train Full Circle 60 kHz: Range (m) Time (sec) Norm Fast 10 8 8 20 8 8 40 8 8 80 120 160 200 250 300 400 500 600 800 1200 1600 8 8 10 10 13 12 16 14 20 16 24 18 32 22 40 26 48 30 64 37 97 54 128 70 150 kHz: Range (m) Time (sec) Norm Fast 10 7 7 20 7 7 40 7 7 60 7 7 80 120 160 200 250 300 400 500 600 800 1000 7 7 10 9 13 11 16 13 20 15 24 17 32 21 40 25 48 28 64 36 81 45 4. 6 Vertical Fan Mode Control SP - 2 E1316S01G Scanning Angle Scanning Center Scanning Step Angle Time to Train 4. 7 Transceiver Beam Width (-3 dB) 6° to 180°, 12° step 0° to 180°, 6° step Normal: 3°, High speed: 6° 360°, 6° step Frequency 60 kHz: 88 kHz: 150 kHz: Vertical 12° 9. 5° 6. 5° Horizontal 15° 11. 5° 6. 5° 4. 8 4. 9 Allowable Ship's Speed Stabilizer 20 knot or less (15 knot during raise/lower operation) Within 30°, optional motion sensor or clinometers required 5 5. 1 5. 2 I/O INTERFACE Data format Input IEC61162-1 (NMEA0183 Ver 1. 5/2. 0) DBS, DBT, DPT, GGA, GLL, HDG, HDM, HDT, MDA, MTW, RMA, RMC, VDR, VHW, VTG 5. 3 Output SSTLL 6 6. 1 POWER SUPPLY Display Unit/ Control Unit/ Transceiver Unit 12-32 VDC: 4. 7-1. 8 A, within 58 VA 6. 2 Hull Unit 12/24-32 VDC: 4. 7/2. 3-1. 8 A, within 58 VA Max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO CH-250




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO CH-250 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.