User manual FUJITSU AOYG09KXCA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FUJITSU AOYG09KXCA. We hope that this FUJITSU AOYG09KXCA user guide will be useful to you.


FUJITSU AOYG09KXCA : Download the complete user guide (1279 Ko)

Manual abstract: user guide FUJITSU AOYG09KXCA

Detailed instructions for use are in the User's Guide.

[. . . ] Human sensor for energy saving setting If timer settings are done from mobile application and from wireless remote controller, both timer settings will be active. 23 or more 74 or more 30 or more 103 or more 30 or more 100 or more 100 or more*2 65 or more 1, 800 or more NOTE: Dual side fans rotate downward when the unit is operating as shown in the figure above. If the depth of the obstruction is larger than 95 mm, secure specified distance*2 in between the indoor unit and the obstruction. Capacity tables show each of following values calculated based on the outdoor temperature and the indoor temperature, under given Airflow Rate (AFR): NOTE: Values mentioned in the table are calculated based on the maximum capacity. [. . . ] Short interval (Approximately once every 3 days) 2) Left/right swing operation range Select the operation range of the left/right swing according to the installation condition. 3) Room temperature control for indoor unit sensor Depending on the installed environment, correction of the room temperature sensor may be required. Select the appropriate control setting according to the installed environment. The temperature correction values show the difference from the Standard setting "00" (manufacturer's recommended value). 4) Auto restart Enables or disables automatic restart after a power interruption. NOTE: Auto restart is an emergency function such as for power outage etc. 5) Remote controller custom code (Only for wireless remote controller) The indoor unit custom code can be changed. 6) Indoor unit fan control for energy saving for cooling Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation. 00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting on the remote controller. 01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed. Set to "00" or "01" when connecting a remote controller that cannot set the Fan control for ener- gy saving function or connecting a network converter. To confirm if the remote controller has this setting, refer to the operating manual of each remote controller. (Set this when the dual fan airflow hits furniture or does not reach the intended area. 9) Maintenance indicator switchover Display/hide the indicator that shows when to clean the dust box or the plasma air clean unit. To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a signal if the air conditioner has not been set for the custom code. When 2 or more air conditioners are installed in a room, and the remote controller is operating an air conditioner other than the one you wish to set, change the custom code of the remote controller to operate only the air conditioner you wish to set. ) Confirm the setting of the remote controller custom code and the function setting. If these do not match, the remote controller cannot be used to operate for the air conditioner. Press the START/STOP button until only the clock is displayed on the remote controller display. Press the MODE button for at least 5 seconds to display the current custom code. If no button is pressed within 30 seconds after the custom code is displayed, the system returns to the original clock indicator. [. . . ] If the drain pipe and drain cap are used, the drain water in the pipe may freeze in extremely cold climate. In area with heavy snowfall, if the inlet and outlet of the outdoor unit is blocked with snow, it might become difficult to get warm, and it is likely to cause product malfunction. Construct a canopy and a pedestal, or place the unit on a high stand that is locally installed. Capacity compensation rate for pipe length and height difference Indoor unit is higher than outdoor unit *1 Indoor unit is lower than outdoor unit *2 NOTE: Values mentioned in the table are calculated based on the maximum capacity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FUJITSU AOYG09KXCA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FUJITSU AOYG09KXCA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.