If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FUJITSU SIEMENS PRIMERGY RX600 S5. We hope that this FUJITSU SIEMENS PRIMERGY RX600 S5 user guide will be useful to you.
Manual abstract: user guide FUJITSU SIEMENS PRIMERGY RX600 S5DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] ENERGY STAR Power and Performance Data Sheet
PRIMERGY RX600 S5 E-StarFam1
System Characteristics
Form Factor Available Processor Sockets Available DIMM Slots / Max Memory Capacity ECC and/or Fully Buffered DIMMs Available Expansion Slots Minimum and Maximum # of Hard Drives Redundant Power Supply Capable? [. . . ] The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2. 0). Closer approximations may be found by using established power calculators and specific information about the intended operating environment (e. g. , average time at Idle data center PUE etc )
Power and Performance for Benchmark #1
Benchma #1 mark Benchmark Used and Type of Workload Avg. Power Measured During Benchmark Run Benchmark P f B h k Performance S Score Power Performance Ratio (perf score/avg. power) Link to Full Benchmark Report (Where Available)
Minimum
698W 149MPi l/ 149MPixel/s 0. 21MPixel/s N/A
Typical
853W 147 62MPi l/ 147, 62MPixel/s 0. 17MPixel/s N/A
Maximum
1078W 149MPi l/ 149MPixel/s 0. 14MPixels/s N/A
SiSoftware Sandra Engineer 2009. SP4, . Net Multimedia, Double x1
Power Saving Features
Processor Dynamic Voltage and Frequency Scaling Processor or Core Reduced Power States Power Capping Variable Speed Fan Control Based on Power or Thermal Readings Low Power Memory States Low Power I/O States Liquid Cooling Capability
Enabled on Shipment
X X X
End-User Enabling Required
Power and Temperature Measurement and Reporting
Input Power Available & Accuracy?Compatible Protocols for Data Collection Averaging method and time period IPMI Linear Average calculation / 5 sec. Yes; +/- 5% Yes; +/- 3°C Yes
Thermal Information *
Total Power Dissipation (watts) Delta Temperature at Exhaust at Peak Temp. [. . . ] Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
Minimum
690 12 520m3/h 180m3/h
Typical
860 16 550m3/h 188m3/h
Maximum
1070 18 558m3/h 228m3/h
* References: ASHRAE Extended Environmental Envelope Final August 1, 2008 Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5 Peak temperature is defined as 35 °C, Nominal Temperature is defined as 18 - 27 °C [. . . ]