User manual FUJITSU SIEMENS PRIMERGY RX300 S6 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FUJITSU SIEMENS PRIMERGY RX300 S6. We hope that this FUJITSU SIEMENS PRIMERGY RX300 S6 user guide will be useful to you.


FUJITSU SIEMENS PRIMERGY RX300 S6 BROCHURE: Download the complete user guide (70 Ko)

Manual abstract: user guide FUJITSU SIEMENS PRIMERGY RX300 S6BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] ENERGY STAR ® Power and Performance Data Sheet PRIMERGY RX300 S6 E-StarFam1 System Characteristics Form Factor Available Processor Sockets Available DIMM Slots / Max Memory Capacity ECC and/or Fully Buffered DIMMs Available Expansion Slots Minimum and Maximum # of Hard Drives Redundant Power Supply Capable? [. . . ] ** Note: Estimated kWh/year gives the absolute range of energy use a user could expect from continuous operation (24x365) and ranges from 100% Idle usage to 100% full load operation. The calculation also includes typical data center overhead at a ratio of 1 watt of overhead to every 1 watt of IT load (corresponding to a PUE of 2. 0). Closer approximations may be found by using established power calculators and specific information about the intended operating environment (e. g. , average time at Idle, data center PUE, etc. ). Power and Performance for Benchmark #1 Benchmark #1 Benchmark Used and Type of Workload Avg. Power Measured During Benchmark Run Benchmark Performance Score Power Performance Ratio (perf score/avg. power) Link to Full Benchmark Report (Where Available) Minimum 184, 1W 35. 72MPixel/s 0, 19MPixels/s/W N/A Typical 247, 4W 37. 57MPixel/s 0, 15MPixels/s/W N/A Maximum 310, 3W 37. 54MPixel/s 0, 12MPixels/s/W N/A SiSoftware Sandra Engineer 2009. SP4, . Net Multimedia, Double x1 Power Saving Features Processor Dynamic Voltage and Frequency Scaling Processor or Core Reduced Power States Power Capping Variable Speed Fan Control Based on Power or Thermal Readings Low Power Memory States Low Power I/O States Liquid Cooling Capability Enabled on Shipment End-User Enabling Required x x x x Power and Temperature Measurement and Reporting Input Power Available & Accuracy?Compatible Protocols for Data Collection Averaging method and time period IPMI Linear Average calculation / 5 sec. [. . . ] Airflow at Nominal Fan Speed (CFM) at Nominal Temp. Minimum 203 9 125m3/h 62m3/h Typical 240 10 130m3/h 68m3/h Maximum 310 12 126m3/h 63m3/h * References: ASHRAE Extended Environmental Envelope Final August 1, 2008 Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5 Peak temperature is defined as 35 °C, Nominal Temperature is defined as 18 - 27 °C [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FUJITSU SIEMENS PRIMERGY RX300 S6




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FUJITSU SIEMENS PRIMERGY RX300 S6 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.