User manual FOSTEX FM-3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FOSTEX FM-3. We hope that this FOSTEX FM-3 user guide will be useful to you.


FOSTEX FM-3 : Download the complete user guide (2019 Ko)

You may also download the following manuals related to this product:

   FOSTEX FM-3 (3896 ko)
   FOSTEX FM-3 BROCHURE (787 ko)

Manual abstract: user guide FOSTEX FM-3

Detailed instructions for use are in the User's Guide.

[. . . ] Owner's Manual Model FM-3 Portable Mixer Thank you very much for purchasing the Fostex FM-3 portable mixer. To ensure the best performance, read this manual thoroughly before using the unit. Keep this manual handy for future reference. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Table of contents Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Adjusting the display brightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Selecting the meter mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Selecting the status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Input status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 T12 power supply mode setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Output status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Limiter parameter setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Meter status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Parameter setting procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Parameter details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Peak meter on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 VU meter reference level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Lighting level of peak over indicator . . . . . . . . . . . . . . . . . . . . . 20 Internal battery selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 System status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Initializing the flash memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Precautions before using . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Precautions on installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Main features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Basic operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Preparation of power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Prepararion of input channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Preparation of output channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Preparation of metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Preparation of monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Master fader reference setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Input setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Names and functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Left side panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Right side panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Main specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 External dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. [. . . ] Pressing it again puts it to the downposition(flatposition). OFF The HPF circuit is bypassed. (leftmost position) ON By turning the control right from the Off position, it clicks and the HPF circuit gets active. Depending on the position, the rolloff frequency changes between 40 Hz and 300 Hz (-12 dB/oct). 12. 16. 13. 14. 17. ON OFF 18. The limiter parameters are factory-preset as shown below. You can change the threshold level and ratio from the output status display (see page 18). ·Attacktime:Approximately5milliseconds(fixed) ·Releasetime:Approximately200milliseconds(fixed) · Threshold: +12 dB (can be changed to +6 dB) · Ratio: 5:1 (can be changed to 3:1) <Factory preset values> Input trim controls (1 through 3) Each control adjusts the input gain of the corresponding input channel. When the input select switch is set to MIC, you can adjust the gain between -70 dBu and -30 dBu. When the input select switch is set to LINE, you can adjust the gain between -20 dBu and +4 dBu. It is recommend to adjust the control so that the PEAK indicator does not light in red at the maximum input level. Channel faders (1 through 3) Each fader controls the signal level sent to the stereo buss. The scale position in orange shows the reference position. 19. 11 Left side panel section 1. [INPUT] connector (1 through 3) Each connector is used to connect an external audio device or microphone. Connector: XLR-3-31 type 1 2 3 GND HOT COLD 5. Microphone power supply switches (T12 / DM /P48) Each switch sets whether or not supplying the microphone power. T12 or AB power supply mode. A 12 V power is supplied to the hot terminal of the [INPUT] connector. T12 <Memo>: If you do not need T12 power supply, you can disable the power supply via the input status display (see page 16 for details). A 48 V power is supplied to the hot and cold terminals of the [INPUT] connector. 2. [AUX IN] connector Used to connect a mixer or audio device. Not only you can monitor the input signal of this connector, you can send the signal to the stereo buss to mix with the main input signals (selectable with the [TO ST BUSS] switch). Connector: XLR-5-51 type 1 2 4 3 5 GND Lch HOT Lch COLD Rch HOT Rch COLD DM P48 6. [DC IN 10-24V] connector Used to connect the supplied AC adaptor (or an external battery). Connector: XLR-4-32 type (male) 1 2 4 3 GND NC DC 10-24V NC 3. [TO ST BUSS] switch (ON / OFF) This switch selects whether or not the input signal from the [AUX IN] connector is sent to the stereo buss. When the switch is set to OFF, the [AUX IN] signal is not sent to the stereo buss. Regardless of the switch setting, you can monitor the [AUX IN] signal via headphones. Input select switches (LINE / MIC) Each switch should be set appropriately according to the input signal source. LINE You should set the switch to LINE when a line-level source is connected to the input connector. When it is set to LINE, the microphone power supply is automatically turned off regardless of its setting. You should set the switch to MIC when a microphone is connected to the input connector. You can supply the microphone power when connecting a condenser microphone (see "Microphone power supply switch" below). 7. [DC OUT 7. 2-24V] connector This connector outputs power at DC 7. 2 ~ 24 V / 0. 5 A for a wireless receiver, etc. [. . . ] You may also have additional rights depending on the state in which the Fostex product was purchased. WARRANTY PROTECTION All Fostex parts are warranted for one (1) year from the date of original purchase, except for recording media, such as hard disc drives and compact flash cards, heads, lamps and fuses, which are warranted, for one hundred-eighty (180) days. Fostex America will repair and / or replace parts during the term of this warranty. Labor costs are also covered by Fostex America for one (1) year from the date of original purchase. Except as specified below, this warranty covers all defects in material and workmanship in this product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FOSTEX FM-3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FOSTEX FM-3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.