User manual FOSTEX CR200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FOSTEX CR200. We hope that this FOSTEX CR200 user guide will be useful to you.


FOSTEX CR200 : Download the complete user guide (2231 Ko)

You may also download the following manuals related to this product:

   FOSTEX CR200 BROCHURE (531 ko)
   FOSTEX CR200 SERVICE MANUAL (2955 ko)
   FOSTEX CR200 SERVICE MANUAL (2955 ko)

Manual abstract: user guide FOSTEX CR200

Detailed instructions for use are in the User's Guide.

[. . . ] Retain instructions - The safety and operating instructions should be retained for future reference. Heed warnings - All warnings on the appliance and in the operating instructions should be adhered to. Follow instructions - All operating and use instructions should be followed. Water and Moisture - The appliance should not be used near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, and the like. [. . . ] 20 32 CR200 4. 3. 17 Fine WBL Offset Adjustment Objective To adjust the gain balance of the wobble signal. Symptom when out of adjustment The unit does not record, search or pause CD-R discs. Measurement instrument connections Oscilloscope to CN104, Pin-5 (WBL) (HEAD BOARD assy) [ This connection must be via high-pass filter (180pF+3. 9k). ] GND probe can be connected to CN104, Pin-4 (AGND). [ Settings ]: 5 mV/div. , 20 S/div. , DC mode Disc STD-R03 Player state Test mode, play Adjustment location VR108 (WBL. OFS) (HEAD BOARD assy) [ Procedures ] (1) Move the pickup to midway across the disc (R = 35mm) with the MANUAL / TRACK SEARCH FWD or REV keys. (2) Press the FINALIZE key, the PLAY key and the PAUSE key in the order to close the respective servos and put the player into play mode. OFS) so that the amplitude of waveform at CN104, Pin-5 (WBL) is minimum. Out of adjustment Optimum adjustment Fig. 21 33 CR200 4. 3. 18 WBL Focus Offset Adjustment Objective To adjust the gain balance of the wobble signal. Symptom when out of adjustment The unit does not record, search or pause CD-R discs. Measurement instrument connections Oscilloscope to CN104, Pin-5 (WBL) (HEAD BOARD assy) [ This connection must be via high-pass filter (180pF+3. 9k). ] GND probe can be connected to CN104, Pin-4 (AGND). [ Settings ]: 5 mV/div. , 20 mS/div. , DC mode Disc STD-R03 Player state Test mode, play Adjustment location VR115 (WFE. (4) Shine the light discharged from the objective lens in the pickup on the light power meter sensor and adjust VR104 (REC. PW) so that the recording laser diode output is an average of 4. 7mW 0. 1mW (Wavelength 790nm, Average mode). P : Playback Power R : Recording Power 4. 3. 20 HF Amp. Gain Adjustment Objective To correct the discrepancy in the HF level with the pickup. Symptom when out of adjustment The unit does not record, track search is impossible. Measurement instrument connections Oscilloscope to CN104, Pin 8 (HF) (HEAD BOARD assy) GND probe can be connected to CN104, Pin-4 (AGND). [ Settings ]: 50 mV/div. , 500 nS/div. , DC mode Disc TCD-785 Player state Test mode, play Adjustment location VR119 (HF. GAIN) (HEAD BOARD assy) [ Procedures ] (1) Move the pickup to midway across the disc (R = 35mm) with the MANUAL / TRACK SEARCH FWD or REV keys. (2) Press the FINALIZE key, the PLAY key and the PAUSE key in the order to close the respective servos and put the player into play mode. (3) Line up bright line (ground) at the center of the oscilloscope screen and put the oscilloscope into DC mode. GAIN) so that the amplitude of waveform at CN104 , Pin-8 (HF) is 2. 0V 0. 1V. NOTE : Adjust after checking that the COPY BIT LED is OFF. 2. 0V 0. 1V Fig. [. . . ] H0 H1 Location of fault H0: Communication is not properly made between mechanism and mode controllers. (See page 42 to check voltage. ) IC360 Fault on loading section is detected. Faulty power supply Checkpoint IC356, IC357, IC207, IC358, IC352, IC353 IC205 H2 H5 L* Recording preparations cannot be performed and tray does not open. ("CHECK" is displayed. ) Unit stops operating while tray is open/close. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FOSTEX CR200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FOSTEX CR200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.