User manual FIRST ALERT FA848C 7-00

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIRST ALERT FA848C. We hope that this FIRST ALERT FA848C user guide will be useful to you.


FIRST ALERT FA848C 7-00: Download the complete user guide (155 Ko)

Manual abstract: user guide FIRST ALERT FA848C7-00

Detailed instructions for use are in the User's Guide.

[. . . ] Previous Menu PRELIMINARY Hardwired/Wireless System FA848C User Guide N9939 7/00 Table Of Contents QUICK REFERENCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SYSTEM REFERENCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 TURNING THE SYSTEM ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 TURNING THE SYSTEM OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 USER CODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MISCELLANEOUS COMMANDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TESTING THE SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] TURN PAGER REPORTING ON/OFF FOR A USER You can turn on/off the open. close reporting feature for a user by doing the following : [#] [7] [master code] [user number] [4] - 22 - Testing The System SYSTEM TEST It is recommended that you test your system once a week using the following procedure: NOTE: If your system is monitored, contact your central station before you perform this test. Then activate the system by opening a protected zone (for example: a window or door). If your system is connected to a central station, the keypad will sound the ringback tone to confirm that the signal was received. BATTERY TEST It is recommended that you test your battery once a month. In order to test your backup/standby battery, the following procedure should be followed: 1. Unplug the transformer from the AC outlet by removing the restraining screw that secures the transformer to the wall. Plug the transformer into the AC outlet and secure with the restraining screw. (NOTE: the screw is not present on the models sold in Canada. ) The National Fire Protection Association publishes a standard for fire warning equipment (NFPA publication #72). Further information can be obtained by contacting: NFPA Public Affairs Dept. , Batterymarch Park, Quincy, MA 02269. If you have any further questions about the operation of your system, please contact your alarm company. - 23 - Recommendations On Smoke Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below. Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A smoke detector installed outside of each separate sleeping area, in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements and excluding crawl spaces and unfinished attics. In addition, the NFPA recommends that you install heat or smoke detectors in the living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms, basements, and attached garages. - 24 - Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1. Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants. One path of escape should lead to the door that permits normal exit from the building. The other is an alternative route, such as through a window, should your normal escape path be unpassable. Station an escape ladder at such windows if there is a long drop to the ground. Keep these routes free from obstruction and post copies of the escape routes in every room. Establish a common meeting place outdoors, away from your house, where everyone can meet and then take steps to contact the authorities and account for those missing. Choose someone to assure that nobody returns to the house -- many die going back. - 25 - Glossary AC INDICATOR: Small green power on-off light between the center buttons on the keypad. When lit, the system is running on primary power; when not lit, the system is running off the backup battery. ALARM: Sound from keypad or other horn/siren indicates a burglar alarm, fire alarm, or other condition you should be alerted to. [. . . ] Telephone lines are also subject to compromise by sophisticated intruders. However, even if the system responds to the emergency as intended occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately. This equipment, like other electrical devices, is subject to component failure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIRST ALERT FA848C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIRST ALERT FA848C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.