User manual FIRST ALERT FA168CPS 8-02

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIRST ALERT FA168CPS. We hope that this FIRST ALERT FA168CPS user guide will be useful to you.


FIRST ALERT FA168CPS 8-02: Download the complete user guide (1166 Ko)

Manual abstract: user guide FIRST ALERT FA168CPS8-02

Detailed instructions for use are in the User's Guide.

[. . . ] 6HFXULW\6\VWHPV )$&36 )$&3 ARMED READY R A B C D 1 OFF 4 MAX 7INSTANT READY 2 AWAY 5TEST 8 CODE 0 3STAY 6BYPASS 9 CHIME # FA2 60 ARMED READY ON OFF R AWAY 1OFF 4 MAX 7INSTANT 2 AWAY 5TEST 8CODE 0 STAY 3 STAY 6 BYPASS 9 CHIME # PAGE READY FA 5 6 0 8VHU·V*XLGH R K5309-5V1 8/02 1 IMPORTANT! PROPER INTRUSION PROTECTION For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building. In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to the Central Monitoring Station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines). EARLY WARNING FIRE DETECTION Early warning fire detection is important in a home. Smoke and heat detectors have played a key role in reducing fire deaths in the United States. [. . . ] · An optional, predefined 16-digit character string can precede the 7-digit system status code; these characters can consist of a PIN no. , subscriber account no. , or any additional data that you may wish to have sent to the pager. · The pager display format is as follows: Optional 16 digits AAAAAAAAAAAAAAAA ­ BBB ­ CCCC Å 1-digit Partition No. or User No. A= Optional 16-digits for Account numbers, PIN numbers, or any other data; programmed by the installer, if required. È 3-digit Event Code È B= A 3-digit code that describes the event that has occurred in your system (see for event codes table below) C= A 1-digit Partition number plus a 3-digit Zone or User number, depending on the type of event that has occurred, where: · alarms and troubles display zone number · arming/disarming (opens/closes) display user number The 3-digit Event Codes (BBB) that can be displayed are: 911 = 811 = 101 = Alarms. 2. ³ = R eporting of an alarm (911) caused by a fault on zone 4 on Partition 1 (1004). ³ = Reporting of a closing­system arming (102)­ by user 5 in Partition 2 (2005). ­ 26 ­ 3DJLQJ)HDWXUH 0DQXDO3DJLQJ Your system may be set up so you can manually send a message to up to four (FA168CPS) or two (FA148CP) pagers. · Your installer programs the paging function key and the pager phone numbers. · Pressing the paging keys sends the message 9 9 9 ­ 9 9 9 9 to the selected pager. · This message could mean "call home", "call your office", or any other prearranged meaning. · See the Paging chart at the back of this manual for details of the paging setup for your system. Press and hold the programmed Paging Key for at least 2 seconds (wait for beep), then press the pager number* representing the pager intended to receive the message. The recipient, on seeing the 999­9999 message, will understand the prearranged meaning of this signal. * If no number is pressed, the message is sent to pager 1. Alpha Display: (-7%61)( 6)%(= 83 %61 Fixed-Word Display: READY Pager Display /DWFK. H\3DJLQJ You can program a schedule that causes a pager report to be sent if the system is not DISARMED by the scheduled time (see Scheduling section, event "03"). For example, a working parent might want a message to be sent to a pager if their child did not arrive home from school and disarm the system by a certain time. If programmed, the message that is sent is: 7 7 7 ­ 7 7 7 7 . ­ 27 ­ 6HFXULW\&RGHV$XWKRULW\/HYHOV $ERXW6HFXULW\&RGHV Your installer assigned a master code that is used to perform all system functions. In addition, you can assign different security codes for use by other users (FA168CPS provides 46 additional codes; FA148CP provides 30 additional codes). · Only the System Master and Partition Master can assign user codes to users. · Users are identified by 2-digit user numbers and are pre-assigned to either partition 1 or partition 2 (FA168CPS). · Only the Installer or System Master can change user partitions. · In addition to a security code, each user is assigned various system attributes. · User codes can be used interchangeably within a partition when performing system functions (a system armed with one user's code can be disarmed by another user's code), with the exception of the guest code described below. Choose a user number from the set of users assigned to the partition in which the user will be operating, and assign a 4-digit security code. Assign other attributes as necessary (see attributes on the next page). NOTE: The factory settings are designed to meet most normal user situations. [. . . ] Telephone lines are also subject to compromise by sophisticated intruders. · Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately. · This equipment, like other electrical devices, is subject to component failure. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIRST ALERT FA168CPS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIRST ALERT FA168CPS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.