User manual FIRST ALERT FA1600C 1-99

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIRST ALERT FA1600C. We hope that this FIRST ALERT FA1600C user guide will be useful to you.


FIRST ALERT FA1600C 1-99: Download the complete user guide (470 Ko)

Manual abstract: user guide FIRST ALERT FA1600C1-99

Detailed instructions for use are in the User's Guide.

[. . . ] )LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHPV ZLWK6FKHGXOLQJ )$&&$&% **** **** ARMED READY A C OFF AWAY B D STAY FIRE 3 FIRE 1 MAXIMUM 2 TEST BYPASS 4 INSTANT 5 CODE 6 CHIME PULL 7 8 0 9 # First Alert READY * Professional 8VHU*XLGH N6020-4V2 1/99 TABLE OF CONTENTS SYSTEM OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 To Access Another Partition (GOTO Command) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Phone Access & Voice Response Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 SECURITY CODES & AUTHORITY LEVELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In the event a user must stay on the premises later than usual, users with master or manager authority levels can manually delay the automatic arming (closing) time up to 2 hours. A menu prompt will be displayed, asking for the number of hours of delay. CLOSING DELAY?The system will automatically exit this mode after entry. Note that the delay is from the scheduled closing time, not from the time the command is entered. The system will automatically send a message to the central station informing them that the programmed schedule has been changed. Temporary Open/Close Schedules Temporary schedules allow you to override the normal schedules programmed by the installer. Temporary schedules can be in effect for up to one week, and take effect as soon as they are programmed. ­ 46 ­ Using Schedules (cont'd) Schedules are comprised of an arming (closing) time window and a disarming (opening) time window. A time window is simply a defined period of time, at the end of which arming or disarming will occur. Before programming a temporary schedule, use a worksheet similar to the one below to plan your schedule. This will make it easier when actually programming the schedule. Arm/Disarm Windows Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM Mon Tue Wed Thu Fri Sat Sun Programming Temporary Schedules Temporary schedules only affect the partition from which it is entered. Temporary schedules can be reused at later dates simply by scrolling (by pressing #) to the DAYS?Note that only users with authority level of manager or higher can program temporary schedules. The following prompts will appear. ­ 47 ­ Using Schedules (cont'd) MON DISARM WIND. 07:45AM 08:45AM The cursor will be positioned on the tens of hours digit of the start time for Monday's disarm window. The AM/PM indication is changed by hitting any key, 0-9, while the cursor is under the letter A/P position. The cursor will be positioned on the tens of hours digit of the start time for the arm window. Repeat the previous steps to enter the start and stop time for Monday's arming window. After the windows for that day have been completed, the system will prompt for disarm and arm time windows for the next day. When all of the days have been completed, the system will ask which days are to be activated. MON ARM WINDOW 07:45AM 08:45AM TUE DISARM WIND. 07:45AM 08:45AM ­ 48 ­ Using Schedules (cont'd) DAYS ?MTWTFSS HIT 0-7 X X This is the prompt that actually activates the temporary schedule, and allows the temporary schedule to be customized to a particular week's needs. To select the days which are to be activated, enter the desired number 1-7 (Monday = 1). An "X" will appear under that day, indicating the previously entered schedule for that day is active. The temporary schedule will only be in effect for the days which have the letter x underneath them. [. . . ] · Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders. · Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIRST ALERT FA1600C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIRST ALERT FA1600C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.