User manual FIELD CONTROLS FORM42

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS FORM42. We hope that this FIELD CONTROLS FORM42 user guide will be useful to you.


FIELD CONTROLS FORM42 : Download the complete user guide (168 Ko)

Manual abstract: user guide FIELD CONTROLS FORM42

Detailed instructions for use are in the User's Guide.

[. . . ] If additional wiring is required, install the flexible conduit connector onto the installer supplied junction box. Fasten the flexible conduit from the SWG Venter into the conduit connector. Mount the CK-41P control box onto a non-heated vertical surface of the appliance or nearby wall or floor joist through the four dimpled locations on the base of the box. [. . . ] Mount the CK-41P control box onto a non-heated vertical surface of the appliance or nearby wall or floor joist through the four dimpled locations on the base of the box. NOTE: The mounted pressure switch diaphragm must be mounted with a vertical orientation; see label on pressure switch. (See Figure 3) If required, run additional wiring as in figure 2 and connect to CK-41P control box, if required, using the supplied flexible conduit connector and approved connectors and anti-short bushings. Attach the 1/4 inch tubing connector to the pressure tube on the SWG Venter. Route the tubing to the CK-41F junction box and connect the tubing to the pressure switch using supplied plastic nut. When routing the tubing, avoid kinking the tubing by bending the tubing too sharply. Support the tubing at 2' intervals using installer supplied tube clamps. PROVING SWITCH ADJUSTMENTS: After proper air flow is established, the pressure switch adjustment is made by turning the pressure switch adjustment screw clockwise (See Fig. Adjust the thermostat and/or aquastat to call for heat and observe the power venting system for proper operation sequence. After a short delay, the relay is energized, the venter motor starts and the vent damper begins opening. Pressure switch closes, the vent damper reaches the open position and the burner starts. Aquastat is satisfied, the burner stops and the vent damper begins closing. This should open the pressure switch contacts and stop burner operation. If no other voltage, the appliance is not calling for heat to the CK-41P. If there is 24 volts continuously for at least 45 second, there should be 115 volts from N to M. If not, the time relay is defective, or L1 and N are not properly wired. [. . . ] If no other voltage, the appliance is not calling for heat to the CK-41P. If there is 24 volts continuously for at least 45 second, there should be 115 volts from N to M. If not, the time relay is defective, or L1 and N are not properly wired. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS FORM42




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS FORM42 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.