User manual FIELD CONTROLS 46457800

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46457800. We hope that this FIELD CONTROLS 46457800 user guide will be useful to you.


FIELD CONTROLS 46457800 : Download the complete user guide (365 Ko)

Manual abstract: user guide FIELD CONTROLS 46457800

Detailed instructions for use are in the User's Guide.

[. . . ] aluminum, copper or stainless steel tubing · Junction box with connectors and additional circuit wiring, if required DO NOT DESTROY THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT WARNING: INSTALLER: IF THE APPLIANCE DOES NOT HAVE A BLOCKED VENT SWITCH, A GSK-3P SPILLAGE SWITCH KIT, P/N 46458600, (NOT INCLUDED) MUST BE INSTALLED (SEE DIAGRAM B). MOUNTING CONTROL BOX The control box must be mounted within 6' of the vent damper, and within reach of the appliance's existing damper cable. If the control box must be mounted out of reach of the power venter's attached wiring, an additional installer supplied junction box and wiring (with approves wiring enclosure if necessary) will be required. [. . . ] WARNING: Failure to properly adjust the pressure switch as specified above could lead to improper operation of the pressure switch, which will result in a hazardous condition and bodily harm! Figure 1 Figure 2 Figure 3 Figure 4 Page 2 WIRING CAUTION: Disconnect electrical power when wiring power venter Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an overcurrent circuit device rated at 15 amperes. CAUTION must be taken to ensure that the wiring does not come into contact with any heat source. All line voltage and safety control circuits, between the venter and the appliance, MUST be wired in accordance with the National Electrical Code for class one wiring or equivalent methods. Route the venter motor and control wiring with an appropriate wiring method. Plug the cable into the receptacle located inside the CK41P using the supplied plastic knockout grommet (if the cable does not have a conduit connector). (See Diagram A) Connect the CK-41P's pre-wired damper cable to the vent damper (See Diagram A). Snap the end of the flexible conduit into place on the vent damper conduit bracket. LINE VOLTAGE WIRING INSTRUCTIONS: 1. Verify that the circuit to be supplying power to the CK-41P is disconnected. Connect the CK-41P green grounding wire to the circuit's ground wire. Connect 120 volts neutral power source wire and white wire from venter motor to terminal N on the CK-41P. [. . . ] Check for 24 volts from both yellow wires on pressure switch to black wire on base of timer relay. If neither yellow wire has 24 volts, the vent damper is defective, has loose wiring, or is not receiving call for heat on the orange wire. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46457800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46457800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.