User manual FIELD CONTROLS 46453400

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46453400. We hope that this FIELD CONTROLS 46453400 user guide will be useful to you.


FIELD CONTROLS 46453400 : Download the complete user guide (1998 Ko)

Manual abstract: user guide FIELD CONTROLS 46453400

Detailed instructions for use are in the User's Guide.

[. . . ] UV-AIRETM AIR PURIFYING SYSTEM Model: UV-12C, 18C, 28C, 28, 12HP, 18HP, 28HP, 12HPC, 18HPC, 28HPC *Exclusive 5 position lamp mounting feature! ITEMS INCLUDED IN KIT: 1-UV-AireTM power unit 4-Sheet metal mounting screws 1-Angled mounting bracket 1-Flat mounting bracket 1-Duct board mounting bracket 1-Ultra Violet lamp 1-Instruction Sheet 1-Wing nut Caution Labels Gasket UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a homes' heating and air conditioning system. The treatment is a safe, silent, and proven way to make your home a healthier place to live. READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE. SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source. · Looking directly at the UVC light may cause permanent eye damage or blindness. [. . . ] Look through view port in the box cover to be sure the lamp is working. (The view port is covered with a plastic lens that blocks the UVC rays. ) If equipped, the LED light will show a continuous "GREEN" color indicating proper unit operation. If lamp still does not glow, contact technical support at 1-252-522-3031 for further assistance. IV. Figure 21 INCORPORATING A THERMOSTAT (Be sure to follow any applicable state or local codes) The UV Aire units supplied with a circuit board allows for the automatic operation of the UV lamp when the there is a call for heating or cooling by the thermostat. After the call for heat has been satisfied, the UV Aire unit will operate for 45 minutes then shut off. Turn off power switch on the UV Aire unit and unplug the unit before doing any wiring. Then plug the UV Aire back into the power receptacle and switch the power switch to the "ON" position SYSTEM CHECK OUT PROCEDURE: 1. With the thermostat set to the heating mode, adjust the thermostat for a call for heat. With the thermostat set to the cooling mode, adjust the thermostat for a call for cooling. After 45 minutes, the UV Aire lamp will turn off. Diagram A WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Avoid touching the glass portion of the lamp with your Page 7 hands. V. ALARM CIRCUIT WIRING The UV Aire units supplied with a circuit board allows for the wiring of the UV Aire unit into an alarm or security system to monitor the operation of the UV lamp. This circuit is a set of normal open contacts that close if the operational time exceeds 9000 hrs or if the lamp burns out. Turn off power switch on the UV Aire unit and unplug the unit before doing any wiring. Plug the UV Aire back into the power receptacle and leave the power switch in the "OFF" position. Unplug the Ballast connector from the lamp and switch the power switch to the ON position. Replace your UV-AireTM Air Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously for maximum lamp life and light effectiveness. VIII. REPLACEMENT PROCEDURE VERY IMPORTANT: Turn switch on unit to "OFF" position and unplug unit from outlet. Loosen the wing nut on swivel bracket and rotate the swivel bracket clockwise. NOTE: When replacing the lamp, always wipe off lamp before installing. NOTE: UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste management authority for local disposal or recycling requirements. [. . . ] The warranty does not cover damage due to accidents, abuse, tampering or misuse, nor does it cover damage resulting from service persons other than Field. Field's liability under this warranty is expressly limited to the repair, replacement, or refund of the invoice price of products which prove to be defective in material or workmanship within a period of ninety days from date of purchase. Field's obligation to repair or replace defective products or refund of invoice price constitutes agreed and liquidated damages for any breach of warranty by Field. FIELD'S LIABILITY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT WITH THE EXCEPTION OF DAMAGES RESULTING FROM FIELD'S FAILURE TO COMPLY WITH FEDERAL OR STATE WARRANTY LAW. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46453400




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46453400 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.