If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46453300. We hope that this FIELD CONTROLS 46453300 user guide will be useful to you.
Manual abstract: user guide FIELD CONTROLS 46453300
Detailed instructions for use are in the User's Guide.
[. . . ] determining your homes needs.
Model Minimum Duct Width Volts Amps Hz Watts Max Air Temp °F Lamp Intensity at 1 meter
II.
See chart below for
Recommended Max Sq. Feet
UV-18X
14
120
1. 0
60
60
190°
2@73 µW/cm2
4000
WARNING: Before installing or servicing a humidifier, air filter, heat system, or this unit, etc. , always turn all power OFF and have units unplugged. WARNING: To prevent water damage or electric shock, do not mount unit under a humidifier. For use on gas fired, oil fired, electric and split system heat pump forced air systems*. [. . . ] (See Figure 12)
3.
Figure 3
Figure 4
Figure 5
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Page 3
Apply supplied "Duct Seal Kit" according to instructions included in kit.
4. Loosen the two side screws on the unit and slide cover off of unit exposing the internal components. (Refer to UV-Aire Configurations in Section III for aid in this decision) a. Remove the two hex nuts and flat bracket from included bagged hardware. Install the flat bracket and secure to the unit base with the hex nuts provided. Angled Bracket Installation NOTE: For angled bracket mounting, refer to specifications outlined by Diagrams A & B for mounting distances in the "Angled Lamp Mounting Bracket Specifications" in section III. Remove the two hex nuts and angled bracket from included bagged hardware. Install the angled bracket and secure to the unit base with the hex nuts provided. (See Figure 15) NOTE: Be sure to note location of lamp hole in bracket relative to unit base.
Figure 15
6. Mount the unit base to the duct using the four mounting screws provided. The oils in your hands may cause the lamp to prematurely expire.
Figure 16 (This figure illustrates duct board mounting, but the procedure is the same for metal duct)
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Avoid touching the glass portion of the lamp with your hands.
Page 4
8. Swing swivel bracket over end of lamp and hand-tighten the wing nut on stud. Plug the power cord into a standard electrical outlet.
NOTE: Seal the joints and seams of the plenum near the mounting location to reduce any direct viewing of light. (The view port is covered with a plastic lens that blocks the UVC rays. ) 15. If lamp still does not glow, contact technical support at 1-252522-3031 for further assistance.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. [. . . ] Any questions, please contact Field Controls at: !Phone: 252-522-3031 "Fax: 252-522-0214 #Email: sales@fieldcontrols. com
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Page 7
IX.
FLEX DUCT INSTALLATION For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 21 below.
Figure 21
WARRANTY INFORMATION
FIVE YEAR LIMITED WARRANTY (excluding lamps, which have a 90 day warranty, from day of installation) The products of The Field Controls Co. are warranted to be free from defects in material and workmanship under normal use for five (5) years from date of manufacture. [. . . ]