User manual FIELD CONTROLS 46382500

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46382500. We hope that this FIELD CONTROLS 46382500 user guide will be useful to you.


FIELD CONTROLS 46382500 : Download the complete user guide (233 Ko)

Manual abstract: user guide FIELD CONTROLS 46382500

Detailed instructions for use are in the User's Guide.

[. . . ] CONTROL KIT Model: CK-50 Designed for use with the SWG Series Power Venter for controlling Natural Gas or L. P. Gas Lochinvar appliances. ITEMS INCLUDED IN KIT: 1 - Junction box with mounted pressure switch and relays 1 - Fan control gas pressure switch 1 - 2 ft. length of 1/4 inch aluminum tubing 2 - Flexible conduit connector 1 - 1/4 inch tubing connector 2630 Airport Road · Kinston, NC 28504 Phone: 252-522-3031 · FAX: 252-522-0214 www. fieldcontrols. com INSTALLATION AND ADJUSTMENTS MOUNTING JUNCTION BOX: The junction box can be mounted at the venter or remotely mounted away from the venter. [. . . ] When routing the tubing, avoid kinking the tubing by bending the tubing too sharply. For remote mounted CK-50 Junction Box, use a 1/4" OD copper, aluminum or plastic tubing and route the tubing to avoid contact with any heat source. PROVING SWITCH ADJUSTMENTS: After proper air flow is established, the pressure switch adjustment is made by turning the pressure switch adjustment screw clockwise (See Fig. Turn the adjustment screw an additional 1/4 to 3/4 turn counterclockwise to ensure adequate switch adjustment. WARNING: Failure to properly adjust the pressure switch as specified above could lead to improper operation of the pressure switch which will result in a hazardous condition and bodily harm!THERMOSTAT HEAT ANTICIPATOR ADJUSTMENT: After venting kit installation and checkout, check the amperage current draw through the thermostat circuit and adjust the thermostat anticipator accordingly. Figure 4 Figure 2 Figure 1 Figure 3 Page 2 WIRING INSTRUCTIONS CAUTION: DISCONNECT ELECTRICAL POWER WHEN WIRING POWER VENTER Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an overcurrent circuit device rated at 15 amperes. CAUTION must be taken to ensure that the wiring does not come into contact with any heat source. All line voltage and safety control circuits, between the venter and the appliance, MUST be wired in accordance with the National Electrical Code for class one wiring or equivalent methods. The wire connections which must be made on a Sidewall Fan can be divided into two categories; Power Connections and Control Voltage. POWER CONNECTIONS The Power Connections bring 120 volts into the fan control box from a designated power source and then sends the same 120 volts out to the fan motor. Step 1 Step2 CONTROL VOLTAGE The Control Voltage brings 120 volts and 24 volts from the boiler to start the fan and make a proving switch, respectively. Step 1 Locate an access panel below the gas train on the left side of the boiler. [. . . ] This should open the pressure switch contacts and stop burner operation. Check gas pressure switch for continuity across terminals when gas valve is pressurized. Check for negative pressure in building. DO NOT DESTROY THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT Installation Information Model No. : ________________________________________ Installer's Name: ___________________________________ Installer's Company: ________________________________ Phone No. : _______________________________________ Date of Installation: _________________________________ Page 4 P/N 46382500 05/00 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46382500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46382500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.