If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46381400. We hope that this FIELD CONTROLS 46381400 user guide will be useful to you.


FIELD CONTROLS 46381400 : Download the complete user guide (837 Ko)

Manual abstract: user guide FIELD CONTROLS 46381400

Detailed instructions for use are in the User's Guide.

[. . . ] Typical problems can be caused by blockage of the intake termination, icing up of the ductwork and effects of leeward side wind effects on a building. VRV OPERATION The VRV gate operates on changes in the vacuum pressure generated by the inlet to the oil burner. During an abnormal operation (i. e. , blockage of the intake or change in external building pressures) an increased negative pressure on the intake of the burner causes a reduction in burner airflow. [. . . ] The pan will be approximately 5/8" from the air adjustment blades. Mount VRV tee assembly or 90° elbow onto the Furnace BootTM intake. Mount the VRV assembly onto the tee and fasten with a screw and nut in collar tabs. To ensure proper operation, check the gate for being level across the pivot points and plumb. Refer to Figure 9 for general installation layout. Figure 6 Figure 5 TERMINATION LOCATION GUIDELINES 1. If mounting on the side of a building prone to drifting snow, mount 12 inches above the snow line. Mount at least 12 inches from either side of the vent termination and on the same wall if sidewall venting. Always mount with the inlet vent termination opening pointing down. Figure 7 Figure 8 Figure 9 Page 3 INSTALLATION OF INLET VENT TERMINATION 1. Slide the inlet vent pipe through the hole and fasten to the wall with appropriate fasteners. Seal the edges of the mounting plate with a silicone sealant or equivalent. Duct length distance, a maximum of 30 linear feet of standard duct pipe and two (2) 90° elbows. Subtract 7 feet from the maximum linear feet for every 90° elbow added. Pipe Diameter 5" 6" Maximum Linear Feet 60' 90' Feet/Elbow* 9' 11' *Subtract footage from the maximum linear feet for every 90° elbow Longer pipe lengths require the use of a larger pipe between the VRV and the intake hood. It also requires the use of a vent pipe increaser at the VRV and a reducer at the intake hood. [. . . ] Set over fire draft to appliance manufacturers' specifications (typically -. 02" of water). If draft levels are not obtainable or controllable, use standard industry methods to control the draft or call the Field Controls Tech Line at 1-800-742-8368 for more information. Table 1 ROUGH AIR SETTING GPH . 75 1. 00 1. 50 Knob Setting 25° 60° 160° 3. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46381400




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46381400 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.