User manual FIELD CONTROLS 46335000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46335000. We hope that this FIELD CONTROLS 46335000 user guide will be useful to you.


FIELD CONTROLS 46335000 : Download the complete user guide (512 Ko)

Manual abstract: user guide FIELD CONTROLS 46335000

Detailed instructions for use are in the User's Guide.

[. . . ] SYSTEM CONTROL KIT Model: CK-41F ITEMS INCLUDED IN KIT: 1) 1) 1) 2) 1) 1) Junction box with mounted pressure switch and post purge timer Fan control gas pressure switch 2 ft. length of 1/4 inch aluminum tubing Flexible conduit connector GSK-3 Spillage switch 1/4 inch tubing connector Designed for use with the SWG Series Power Venter for controlling Natural Gas or L. P. Gas appliances. This device MUST be installed by a qualified agency in accordance with the manufacturers installation instructions. [. . . ] Connect the supplied 1/4" aluminum tubing to the tubing connector. Route the tubing to the CK-41F junction box and connect the tubing to the pressure switch. When routing the tubing, avoid kinking the tubing by bending the tubing too sharply. For remote mounted CK-41F Junction Box, use a 1/4" OD copper, aluminum or plastic tubing and route the tubing to avoid contact with any heat source. A maximum of 80 feet of ¼" tubing can be used with the SWG Series power venter. Page 2 PROVING SWITCH ADJUSTMENTS After proper air flow is established, the pressure switch adjustment is made by turning the pressure switch adjustment screw clockwise (See Figure 4) until burner operation stops. Turn the adjustment screw an additional ¼ to ¾ turn counterclockwise to ensure adequate switch adjustment. WARNING: Failure to properly adjust the pressure switch as specified above could lead to improper operation of the pressure switch, which will result in a hazardous condition and bodily harm!THERMOSTAT HEAT ANTICIPATOR ADJUSTMENT After venting kit installation and checkout, check the amperage current draw through the thermostat circuit and adjust the thermostat anticipator accordingly. Figure 4 WIRING INSTRUCTIONS CAUTION: DISCONNECT ELECTRICAL POWER WHEN WIRING POWER VENTER, Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over-current circuit device rated at 15 amperes. CAUTION must be taken to ensure that the wiring does not come into contact with any heat source. All line voltage and safety control circuits, between the venter and the appliance, MUST be wired in accordance with the National Electrical Code for class one wiring or equivalent methods. Route the venter motor and control wiring with an appropriate wiring method. [. . . ] For furnaces or boilers, adjust the thermostat to call for heat and observe the power venting system for proper operation sequence. This should open the pressure switch contacts and stop burner operation. REPAIR AND REPLACEMENT PARTS REPAIR AND REPLACEMENT PARTS LIST DESCRIPTION Pressure Switch Post Purge Timer PART NUMBER 46083000 46282800 Page 7 INSTALLATION INFORMATION CK-41F MODEL NO. :____________________________________________________________ INSTALLER'S NAME:_____________________________________________________ INSTALLER'S COMPANY: _________________________________________________ INSTALLER'S PHONE NO. : ________________________________________________ DATE OF INSTALLATION:_________________________________________________ Page 8 P/N 46335000 Rev A 10/06 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46335000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46335000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.