User manual FIELD CONTROLS 46334800

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46334800. We hope that this FIELD CONTROLS 46334800 user guide will be useful to you.


FIELD CONTROLS 46334800 : Download the complete user guide (1198 Ko)

Manual abstract: user guide FIELD CONTROLS 46334800

Detailed instructions for use are in the User's Guide.

[. . . ] SIDEWALL POWER VENTING SYSTEM Model: SWG-4G ITEMS INCLUDED IN KIT 1 - SWGII-4HD Sidewall Power Venter 1 - CK-43F Control Kit (includes 4" MG-1 Barometric Draft Control) 1 - Installation Instructions OPTIONAL COMPONENTS PEK-4HD Extension Kit. GENERAL SYSTEM INFORMATION Designed for operation with natural gas and LP gas. The thermostat calls for heat and energizes a relay which activates the power venter. After the venter motor has come up to speed, the pressure switch closes. [. . . ] Secure the vent pipe to the SWG power venter inner pipe with at least (3) three #8 sheet metal screws. Pre-drilling the holes through both pipes will allow easier fastening. Figure 4 Page 4 PEK-4HD EXTENSION KIT INSTALLATION INSTRUCTIONS (Optional) (Includes an air adjustment damper plate) 1. Using a pair of sheet metal cutters, cut the Damper Plate Adjustment Bracket. Install the Extension by starting the inner pipe into the attaching section first, then lightly tap the end of the inner and outer pipe into the attaching section until the rib on the crimped end touches the attaching pipe. NOTE: The Extension Kit can be added onto the SWG Venter directly or by attaching equal lengths of pipe to the inner and outer pipes, then the Extension Kit can be added closer to the heating unit. Make sure damper plate rotates freely, then fasten the outer pipe with at least (3) three sheet metal screws. INSTALLATION INSTRUCTIONS FOR CK-43F CONTROL KIT Designed for use with the SWG Series Power Venter for controlling Natural Gas and L. P. ITEMS INCLUDED IN CK-43F CONTROL KIT: 1) Junction box with mounted air pressure switch and post purge relay/timer. 1) 1/4 inch tubing connector 1) Flexible conduit connector 1) 4" MG-1 Barometric Draft Control DRAFT CONTROL INSTALLATION 1. Install a vent pipe reducer or increaser, if needed, into the tee and fasten using sheet metal screws. If using a Type B Vent Tee, the opening of the Tee, at the draft control mounting location, should be sealed with a high temperature sealant or equivalent. The front face of the control MUST be plumb and the bearing surfaces MUST be level whether the control is on a horizontal, vertical or sloping flue pipe. NOTE: Do not install the draft control in a vent pipe tee in the configuration as shown in Figure 8. MOUNTING JUNCTION BOX The junction box can be mounted near the venter or remotely mounted up to 100 feet away from the venter. Remove one of the knockouts from the side of the junction box where the pressure switch is mounted. Install the flexible conduit connector onto the CK-43F junction box and secure with fastening nut. If remote mounting the CK-43F junction box, mount the flexible conduit connector onto a 2" x 4" installer supplied junction box. Fasten the flexible conduit from the SWG Venter into the conduit connector. Adjust the thermostat to call for heat and observe the power venting system for proper operation sequence (Repeat if necessary. ) a. After verifying the correct operation of the system as stated above, repeat the procedure. While the appliance is operating, disconnect power to the Power Venter motor. As the venter motor slows, the air pressure switch contacts will open and stop the appliance burner operation. [. . . ] Corrections must be made before the appliance is put into continuous operation. If, after completing Steps 3 through 7, it is believed sufficient combustion air is not available, refer to the National Fuel Gas Code, ANSI Z223. 1, CAN/CGA B149. 1M91 or CAN/CGA B149. 2-M91, or any applicable local codes for guidance. Visually inspect the venting system for proper size and determine that there is no flue gas spillage, blockage, restriction, leakage, corrosion, or other deficiency which could cause an unsafe operation. Insofar as practical, close all building doors, fireplace dampers, windows, and all doors in area in which the appliance is located. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46334800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46334800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.