User manual FIELD CONTROLS 46334200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46334200. We hope that this FIELD CONTROLS 46334200 user guide will be useful to you.


FIELD CONTROLS 46334200 : Download the complete user guide (1287 Ko)

Manual abstract: user guide FIELD CONTROLS 46334200

Detailed instructions for use are in the User's Guide.

[. . . ] International Comfort Products (Adjustable) International Comfort Products (Fixed) Lennox International Inc. Page 2 4 6 7 8 10 11 13 14 16 17 18 19 Field Controls, L. L. C. , 2630 Airport Road, Kinston, NC 28504 Technical Support (800) 742-8368 SWG-4AM AMANA SIDEWALL POWER VENTING KIT Field Controls P/N 46205411 Kit Includes: SWGII-4HD Sidewall Power Venter CK-43 Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Adjustable Post Purge Recommended For Use On The Following Amana Model Furnaces: GBI GCIA GCIC GMI GUI GUIB GUID GCIB GCI GSI GHI GUIC GUIA NOT For Use On The Following Amana Model Furnaces: GCIS GUIS GUIV Furnace Configuration and Vent Pipe Restrictions Type B-1 vent pipe shall be used to join the furnace to the venting system and for the entire length of the venting system. Exception: Up to 24" of single wall vent pipe may be used to connect the furnace to the barometric damper. Type B-1/double wall vent pipe MUST be used from the barometric damper tee to the power venter. [. . . ] long, up to 4 elbows, and 1 tee § PERMITTED WITH ALL GAS INPUT SIZES A reducer is required between furnace and vent for these inputs: up through 105, 000 Btu/hr 4"-to-3" more than 105, 000 Btu/hr 5"-to-3". PERMITTED WITH GAS INPUTS OF 88, 000 Btu/hr AND LESS A 4"-to-3" reducer is required between furnace and vent. Draft Safeguard Switch Assembly Two-Stage models 58UXT 330JAV 58DXT 331JAV 58UXV 333JAV 58UHV 333BAV 58TUA 330AAV 58TMA 331AAV Single-Stage models 58WAV 395CAV 58ZAV 376CAV 58PAV 383KAV 58RAV 373LAV GB1AAV 480BAV GB3AAV 481BAV PERMITTED WITH OR WITHOUT THE DRAFT SAFEGUARD * PERMITTED ONLY WITH THE DRAFT SAFEGUARD Page 8 * § The furnace's Draft Safeguard switch assembly can remain in place as installed at the factory, or the Draft Safeguard switch assembly can be removed (relief box opening sealed with Block-off Plate and switch replaced with Splice Connector from Kit KGASW0101/02012SP). The Draft Safeguard switch assembly must remain installed and operational in the furnace. 3"-to-4" increaser is required between vent pipe and power venter. General Wiring: For complete installation information refer to the Field Controls SWGII-4CC Power Venter Installation Manual for details (P/N 46295100. ) Page 9 SWG-4CD CONSOLIDATED SIDEWALL POWER VENTING KIT Field Controls P/N 46205408 Kit Includes: SWGII-4HD Sidewall Power Venter WMO-1 Thermal Safety Switch (Must be purchased separately if using other venting kit on Consolidated Furnaces. ) CK-43F Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Fixed post purge For use with the following series of furnaces: This furnace was built by CONSOLIDATED INDUSTRIES under the names: QUATRO, TECH-4, QUADPRO, QUADTECH, MULTIFLOW, BRENTWOOD, and SUNBURST. Model Numbers: MAA040NR2R MBA040NH2R MCA040NR2R MDA040NH2R MAA040NR3R MBA040NH3R MCA040NR3R MDA040NH3R MAA060NR2R MBA060NH2R MCA060NR2R MDA060NH2R MAA060NR3R MBA060NH3R MCA060NR3R MDA060NH3R MAA060NR4R MBA060NH4R MCA060NR4R MDA060NH4R MAA080NR2R MBA080NH2R MCA080NR2R MDA080NH2R MAA080NR3R MBA080NH3R MCA080NR3R MDA080NH3R MAA080NR4R MBA080NH4R MCA080NR4R MDA080NH4R MAA080NR5R MBA080NH5R MCA080NR5R MDA080NH5R MAA100NR3R MBA100NH3R MCA100NR3R MDA100NH3R MAA100NR4R MBA100NH4R MCA100NR4R MDA100NH4R MAA100NR5R MBA100NH5R MCA100NR5R MDA100NH5R MAA120NR4R MBA120NH4R MCA120NR4R MDA120NH4R MAA120NR5R MBA120NH5R MCA120NR5R MDA120NH5R MAA140NR4R MBA140NH4R MCA140NR4R MDA140NH4R MAA140NR5R MBA140NH5R MCA140NR5R MDA140NH5R Note: Model numbers may have suffix "X". This kit may also be used with furnaces manufactured by Consolidated Industries and sold by a number of other companies under their names. This furnace was built by CONSOLIDATED INDUSTRIES under the name PREMIER. Model Numbers: HBA040NR3R HBA060NR4R HBA080NR4R HBA100NR5R HBA120NR5R Note: Model numbers may have suffix "X". This kit may also be used with furnaces manufactured by Consolidated Industries and sold by a number of other companies under their names. General Information: Page 10 1. 2. Maximum equivalent vent length is 63 feet for all furnaces listed!The SWG-4CD power venter kit must be installed using type B-1 vent pipe only! General Wiring For complete installation information refer to the Field Controls SWG-4CD Power Venter Installation Manual for details (P/N 46333600. ) SWG-4D DUNKIRK SIDEWALL POWER VENTING KIT Field Controls P/N 46205406 Kit Includes: SWGII-4HD Sidewall Power Venter CK-43D Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Adjustable post purge For use with the Dunkirk Radiator Boiler Models XEB 2-5 or Equivalent* *To determine equivalent models, call (716)366-5500 and ask for Technical Service Department Unit Sizing and Equivalent Footage Max. Horizontal Vent Run 50'+ Tee with a 3"x4" increaser for the barometric draft control + 3"x4" increaser with power venter Min. Horizontal Vent Run 2'+ 90° elbow + tee with a 3"x4" increaser for the barometric draft control + 3"x4" increaser with power venter For additional elbows, reduce the maximum vent length as follows: Page 11 3" x 90° elbow - reduce vent length by 3 feet for each elbow Standard 3" single walled galvanized venting or 3" Type B vent pipe should be used. Install a 3" vent pipe tee of the same material as the vent piping 12" to 24" away from the outlet of the boiler's blower. Then place a 3"X4" reducer in the tee for mounting the barometric draft control as shown in the Figure below. Seal the vent pipe tee and reducer using the sealing and joining procedures in the boiler installation instructions. Seal the barometric draft control into the tee using the same high temperature silicone as used on the vent piping. The front face of the control MUST be plumb and the bearing surfaces MUST be level whether the control is on a horizontal, vertical, or sloping vent pipe. [. . . ] Under no circumstances can a furnace equipped with a natural draft diverter be horizontally vented. Page 18 Vent Specifications: 1. The maximum vent length is 30 feet with a maximum of three 90° elbows. When 3" vent pipe is used, a 3" to 4" single wall increaser is required for connecting the barometric damper and for connecting the power venter. A single wall increaser will also be required at the furnaces with 3" outlet collars when 4" vent pipe is used. General Wiring For complete installation information refer to the Field Controls SWG-4R Power Venter Installation Manual for details (P/N 46331300. ) SWG-4Y YORK SIDEWALL POWER VENTING KIT Field Controls Part #46205404 Kit Includes: SWGII-4HD Sidewall Power Venter CK-43F Control Kit Includes: 4" MG-1 Barometric Draft Control Fan Proving Switch Fixed post purge Approved For Use On The Following York International Model Furnaces: Page 19 P1UK PAKU P2MP PBKM P9MP XEM P2DP PBKD P3UC XED P9UC PCMU P3CC PKMU P9CC PCMD PKMD Unit Sizing And Equivalent Footage Refer to the following to choose the proper size vent pipe and fittings for connecting the SWG power venter to the appliance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46334200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46334200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.