User manual FIELD CONTROLS 46304000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46304000. We hope that this FIELD CONTROLS 46304000 user guide will be useful to you.


FIELD CONTROLS 46304000 : Download the complete user guide (418 Ko)

Manual abstract: user guide FIELD CONTROLS 46304000

Detailed instructions for use are in the User's Guide.

[. . . ] 120 VAC SYSTEM CONTROL KIT Model: CK-66 & 67 CK-66 CK-67 Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with Honeywell R8184P primary control. NOTE: The system requires a Honeywell R8184P primary control and an oil delay or solenoid valve supplied with equipment or installer supplied ITEMS INCLUDED IN KIT 1) Junction box with mounted pressure switch control 1) 2 Ft. Length of 1/4 inch aluminum tubing 1) 1/4 inch tubing connector 1) Flexible conduit connector 1) WMO-1 Secondary Safety Switch 1) 120 VAC Relay (CK-67 only) DO NOT DESTROY THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT MOUNTING JUNCTION BOX The junction box can be mounted at the venter or remotely mounted away from the venter. [. . . ] CAUTION: If for any reason the system has shut down during operation, the cause of the system failure should be investigated and corrected before resetting the safety switch and restarting the system. Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over current circuit device rated at 15 amperes. CAUTION must be taken to ensure that the wiring does not Figure 5 come into contact with any heat source. All line voltage and safety control circuits, between the venter and the appliance, MUST be wired in accordance with the National Electrical Code for Class I wiring or equivalent methods. Route the venter motor and control wiring with an appropriate wiring method. Attach the 1/4 inch tubing connector to the pressure tube on the SWG Venter. Connect the supplied 1/4" aluminum tubing to the tubing connector. Route the tubing to the CK-66 or 67 Junction Box and connect the tubing to the pressure switch. When routing the tubing avoid kinking the tubing by bending the tubing too sharply. For remote mounted CK-66 or 67 Junction Box, use a 1/4" OD copper, aluminum or plastic tubing and route the tubing to avoid contact with any heat source. Refer to the SWG Venter installation instructions for setting system airflow. Page 2 Diagram A ­ CK-66 Single Appliance Wiring Diagram B ­ CK-67 Multiple Appliance Wiring Page 3 PRESSURE SWITCH ADJUSTMENTS With the venter air flow set and the appliance operating at the best operating efficiency, adjust the pressure switch by rotating the adjustment screw clockwise until the burner shuts off, then rotate the adjustment screw counterclockwise until the burner fires. Rotate the adjustment screw an additional 1/4 turn counterclockwise to ensure proper switch setting. [. . . ] Wheel: Inspect venter wheel annually, for oil fired heating systems, clear any soot, ash or coating, which inhibits either rotation or air flow. Vent System: Inspect all vent pipe connections annually for looseness and for evidence of flue gas leakage. INSTALLATION INFORMATION CKMODEL NO. :_____________________________________________________________ INSTALLER'S NAME:______________________________________________________ INSTALLER'S COMPANY:__________________________________________________ INSTALLER'S PHONE NO. :_________________________________________________ DATE OF INSTALLATION: _________________________________________________ Page 4 P/N 46304000 Rev C 04/01 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46304000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46304000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.