User manual FIELD CONTROLS 46285300

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46285300. We hope that this FIELD CONTROLS 46285300 user guide will be useful to you.


FIELD CONTROLS 46285300 : Download the complete user guide (799 Ko)

Manual abstract: user guide FIELD CONTROLS 46285300

Detailed instructions for use are in the User's Guide.

[. . . ] Fasten the CK-91F junction box through the four dimpled locations on the base of the box. Attach the 1/4 inch tubing connector to the pressure tube on the SWG Venter. Connect the supplied 1/4" aluminum tubing to the tubing connector. Route the tubing to the CK-91F junction box and connect the tubing to the pressure switch. [. . . ] WHAT DRAFT SETTING TO USE When adjusting the control, two things are essential; 1. The burner must be operating for at least 10 minutes to obtain maximum chimney draft. An analysis of the flue gases is necessary to determine the percentage of CO2 and check for presence of CO. Refer to the appliance instructions and/or to the local gas company for the proper CO2 readings and allowable CO levels. A rule of thumb for draft setting is between . 01" to . 03" of water column draft at the appliance outlet. (Check equipment requirement. ) Changes in the adjustment of the 4" MG1 control should be made by adding or removing the washer-like weights (supplied with the control) to or from the weight holder chain assembly. After the control is adjusted, it's action will be entirely automatic, the gate will open or close by itself to correct for changes in the draft that occur in the chimney. Page 3 ADJUSTMENTS PROVING SWITCH ADJUSTMENTS After proper airflow is established, the pressure switch adjustment is made by turning the pressure switch adjustment screw clockwise (See Figure 7) until burner operation stops. Turn the adjustment screw an additional 1/4 to 3/4 turn counterclockwise to ensure adequate switch adjustment. WARNING: Failure to properly adjust the pressure switch as specified above could lead to improper operation of the pressure switch which will Figure 7 result in a hazardous condition and bodily harm!THERMOSTAT HEAT ANTICIPATOR ADJUSTMENT After venting kit installation and checkout, check the amperage current draw through the thermostat circuit and adjust the thermostat anticipator accordingly. INSTALLATION OF GAS PRESSURE SWITCH CAUTION: Check gas control valve pressure. (See Figure 8) NOTE: If installing on an existing appliance, shut off gas supply to gas valve before plug removal. Replace the pressure tap plug with the 1/8" pipe nipple and pipe tee. The gas pressure switch is supplied with a restrictor orifice in the inlet and outlet ports. CAUTION: If for any reason the system has shut down during operation, the cause of the system failure should be investigated and corrected before resetting the safety switch and restarting the system. Figure 10 DRAFT HOOD SAFETY SWITCH INSTALLATION PROCEDURE Figure 11 NOTE: 12 ga. wire should be used when wiring safety spillage switches, to reduce the voltage drop in the thermocouple circuit. Thread the junction block into the thermocouple port and thermocouple into the bottom of the junction block. Connect lead wire from the junction block to the jacketed lead wires or wire enclosed in an accepted wiring enclosure. (See Figure 11) NOTE: Draft spillage switches should be mounted 90 degrees apart, and mounted opposite from the vent outlet direction. Mount the two spillage switches onto the draft hood and connect inside terminals of switches with jumper wire. Connect outside terminals to lead wires which are connected to the thermocouple junction block. [. . . ] Refer to the SWG Venter installation instructions for setting system airflow. Diagram A Page 5 Diagram B INTERNAL WIRING FOR CK-CONTROL KIT: DIAGRAM A & B L1 to 1 on timer M to 3 on timer T1 to common on pressure switch T2 to timer relay base T3 to N/O on pressure switch Timer base to common on pressure switch SYSTEM CONTROL CHECK OUT PROCEDURES For furnaces or boilers, adjust the thermostat to call for heat and observe the power venting system for proper operation sequence. This should open the pressure switch contacts and stop burner operation. Page 6 PRESSURE SWITCH FOR WATER HEATER 1. Then adjust the thermostat to call for heat, which will energize the venter motor. Turn gas control valve to the PILOT position, which will start a 1 to 3 min. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46285300




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46285300 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.