User manual FIELD CONTROLS 46149200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46149200. We hope that this FIELD CONTROLS 46149200 user guide will be useful to you.


FIELD CONTROLS 46149200 : Download the complete user guide (1812 Ko)

Manual abstract: user guide FIELD CONTROLS 46149200

Detailed instructions for use are in the User's Guide.

[. . . ] Install the flexible conduit connector onto the CK-62 Junction Box and secure with fastening nut. If remote mounting the CK-62 Junction Box, mount the flexible conduit connector onto a 2" x 4" installer supplied junction box. Fasten the flexible conduit from the SWG Venter into the conduit connector. [. . . ] Using a screw driver, turn the adjustment screw counterclockwise to increase purge time and clockwise to decrease purge time. Adjust purge time until no flue gas smell is apparent after venter stops. (See Figure 7) CHART A Close on 150°F to rise temperature 200°F ± 15°F Open on 95°F to fall temperature 130°F ± 15°F Typical post purge time should be 3 to 5 minutes Figure 7 Figure 6 Page 3 WIRING INSTRUCTIONS Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations and/or applicable local codes. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over current circuit device rated at 15 amperes. CAUTION must be taken to ensure that the wiring does not come into contact with any heat source. All line voltage and safety control circuits, between the venter and the appliance, MUST be wired in accordance with the National Electrical Code for Class I wiring or equivalent methods. Route the venter motor and control wiring with an appropriate wiring method. Refer to the Wiring Diagrams A through E. Diagram A ­ Oil Fired System: Single Unit Wiring Page 4 Diagram B ­ Oil Fired System: Wiring with Electronic Primary Page 5 Diagram C ­ Typical Wiring for Oil Fired Warm Air Furnace with a Honeywell ST9103 Control Board Page 6 Diagram D ­ Riello Burner Application Page 7 Diagram E ­ Multiple Oil Fired Systems Page 8 PRESSURE SWITCH SENSING TUBE INSTALLATION 1. Attach the 1/4 inch tubing connector to the pressure tube on the SWG Venter. Connect the supplied 1/4" aluminum tubing to the tubing connector. Route the tubing to the CK-62 Junction Box and connect the tubing to the pressure switch. When routing the tubing avoid kinking the tubing by bending the tubing too sharply. For remote mounted CK-62 Junction Box, use a 1/4" OD copper, aluminum or plastic tubing and route the tubing to avoid contact with any heat source. Refer to the SWG Venter installation instructions for setting system airflow. PRESSURE SWITCH ADJUSTMENTS With the venter air flow set and the appliance operating at the best operating efficiency, adjust the pressure switch by rotating the adjustment screw clockwise until the burner shuts off, then rotate the adjustment screw counterclockwise until the burner fires. [. . . ] Main burner does not fire when thermostat calls for heat with venter operating. Check pressure switch for continuity across terminals, during venter operation. Wheel: Inspect venter wheel annually, for oil fired heating systems, clear any soot, ash or coating which inhibits either rotation or air flow. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46149200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46149200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.