User manual FIELD CONTROLS 46139100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46139100. We hope that this FIELD CONTROLS 46139100 user guide will be useful to you.


FIELD CONTROLS 46139100 : Download the complete user guide (620 Ko)

Manual abstract: user guide FIELD CONTROLS 46139100

Detailed instructions for use are in the User's Guide.

[. . . ] SIDEWALL POWER VENTER KIT Model: SWG, SWGII & SWG Stainless Series *Patented CK series control kit sold separately TYPICAL VENTING SYSTEM COMPONENTS 1 - SWG Series Power Venter 1 - CK Series Control Kit (sold separately) OPTIONAL SYSTEM COMPONENTS SWG SERIES THROUGH-WALL EXTENSION KIT For installation in wall thickness over 8 inches. FOR MOST MULTIPLE HEATING EQUIPMENT SYSTEMS One CK Series Control Kit for each appliance. Except for a 24V gas furnace or boiler and a 30mV water heater multiple venting system, use the CK-90 Series Control Kit. 11 GENERAL SYSTEM INFORMATION Designed for operation with natural gas, LP gas and #2 fuel oil appliances. [. . . ] For installation in wall thicknesses over 8 inches, use an SWG Series Though Wall Extension Kit, Model PEK. Remove the end pipe cover screws on the sides of the outside pipe and remove end pipe cover. Then mount the backing plate over the outer pipe and route the flexible conduit and pressure switch tube (if applicable) through the holes provided in the backing plate. Fasten the backing plate to the inside wall with appropriate fasteners. To install an outer pipe extension to the SWG power venter, the end pipe cover on the power venter must be removed. Then, cut a 1-inch square notch into the vent pipe extension before attaching the power venter. Install the needed pipe extensions and terminate the outer pipe extension with the end pipe cover (see Diagram B). The table above shows minimum allowable clearances when using single or double pipe systems. When the outer pipe is extended over the inner pipe, use the double pipe guidelines when determining clearances. Figure 6 shows how the airflow pattern through an SWG reduces the required clearances to combustibles. NOTE: Vent pipe joints should be secured with at least (3) three sheet metal screws. Figure 5 Page 6 Figure 6 CLASS B AND CLASS L DOUBLE WALL VENT PIPE INSTALLATION (Follow vent pipe manufacturer's listed or recommended clearances from combustible material) Figure 7 1. Using a hand crimper or a like device, crimp the inner pipe of the SWG power venter approximately 1" long. Attach the vent pipe over the crimped end of the SWG power venter inner pipe. Secure the vent pipe to the SWG power venter inner pipe with at least (3) three #8 sheet metal screws. Pre-drilling the holes through both pipes will allow easier fastening. WIRING NOTE: Refer to appropriate control kit for proper installation instructions. Wire the power venter motor and controls in accordance with the National Electric Code and applicable local codes. Check ground circuit to make certain that the unit has been properly grounded. The wiring should be protected by an over-current circuit device rated at 15 amperes. CAUTION MUST be taken to ensure that the wiring does not come in contact with any heat source. All line voltage and safety control circuits, between the power venter and the appliance, MUST be wired in accordance with the National Electrical Code for Class 1 wiring or equivalent. AIR FLOW ADJUSTMENTS In order to obtain proper system draft, the power venter has an airflow adjustment damper built in. [. . . ] The Repair Motor Assembly contains the Motor and Blower Wheel factory assemble to a mounting bracket. PART NUMBERS MODEL SWG-3 SWG/SWGII-4HD SWG-4s SWG/SWGII-5 SWG-5s SWG/SWGII-6 SWG-6s SWG-7 SWG-8 REPAIR MOTOR ASSEMBLY 46196601 46234800 BLOWER WHEEL 46131800 46310400 46234900 46213800 46235000 46152401 46460101 46385800 46154700 46154800 SWG Repair Motor Assembly SWGII Repair Motor Assembly Blower Wheel REMOVAL AND INSTALLATION OF THE SWG SERIES POWER VENTER MOTOR ASSEMBLY REMOVAL 1. Rotate the motor assembly counter-clockwise and slide the assembly into the center. Clean off any build-up inside the blower wheel housing and the blower wheel. CAUTION: Avoid applying excess pressure on the blower wheel when cleaning off any build-up of material. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46139100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46139100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.