User manual FIELD CONTROLS 46115300

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46115300. We hope that this FIELD CONTROLS 46115300 user guide will be useful to you.


FIELD CONTROLS 46115300 : Download the complete user guide (696 Ko)

Manual abstract: user guide FIELD CONTROLS 46115300

Detailed instructions for use are in the User's Guide.

[. . . ] For operation with 750 millivolt operated boilers, furnaces, water heaters, pool or spa heaters and gas-fired fireplaces when operating with a remote mounted 24 VAC thermostat. For operation with a 120 VAC thermostat or wall switch, use the CK-80. For operation with a draft induced gas-fired furnace or boiler and a 30 millivolt operated water heater. Use the CK-91F or 92F for a non-adjustable post purge relay/timer. CK-61: CK-81: CK-91: II. SYSTEM OPERATION A. [. . . ] For oil appliances use a Field Controls Type M or RC Barometric Draft Control. Gas-fired draft induced systems should have a single-acting or double-acting barometric draft control installed. V. INSTALLATION OF POWER VENTER CAUTION: Failure to install, maintain and/or operate the power venting system in accordance with manufacturer's instructions will result in conditions which may produce bodily injury and/or property damage. If the carton has been crushed or mutilated, check unit very carefully for damage. Rotate venter wheel to insure that the motor and venter wheel rotate freely. Location of the termination of the venting system should be installed in accordance with the National Fuel Gas Code, A. N. S. I. Z233. 1, manufacturer's recommendations, and/or local codes which are applicable. See the following requirements or refer to installation location Diagram A for typical locations. The exit termination of mechanical draft systems shall not be less than 7' above grade when located adjacent to public walkways. A venting system shall terminate at least 3' above any forced air inlet located within 10'. The venting system of other than a direct vent appliance shall terminate at least 4' below. 4' horizontally from or 1' above any door, window or gravity air inlet into the building. The vent termination of a direct vent appliance with an input of 50, 000 BTU/Hr or less, shall be located at least 9" from any opening through which vented gases could enter the building. With an input over 50, 000 BTU/Hr, a 12" termination clearance shall be required. The vent termination point shall not be installed closer than 3' from an inside corner of an L-shaped structure. The vent termination should not be mounted directly above or within 3' horizontally from an oil tank vent or gas meter. The bottom of the vent terminal shall be located at least 12" above finished grade. B. 4. 5. The power venter should never be installed with the venter motor in the vertical position. The venter outlet can be oriented at any angle, from horizontal to vertical. The power venter should be installed as close to the outside wall as possible. Page 6 Diagram A PVE Side Wall Vent Termination Locations VI. CONNECTING VENTER TO APPLIANCE: The venting system should be installed and supported in accordance with the National Fuel Gas Code A. N. S. I. Z223. 1, or in accordance with any local codes. A vent pipe connector shall be supported for the design and weight of the material employed, to maintain clearances, prevent physical damage and separation of joints. A vent pipe increaser or reducer may be required for connecting the venter to the vent system. Smaller vent pipe sizes than a chimney-vented system may be used for the vent system. [. . . ] Turn on all fuel burning appliances within the same room so that they will operate at their maximum input. Return doors, windows, exhaust fans, fireplace dampers and any other fuel-burning appliances to their previous condition of use. 2. 3. Wheel: Inspect the venter wheel annually to clear any soot, ash or coating which inhibits either rotation or air flow. Vent System: Inspect all vent connections annually for looseness, for evidence of corrosion and for flue gas leakage. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46115300




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46115300 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.