User manual FIELD CONTROLS 46091800

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 46091800. We hope that this FIELD CONTROLS 46091800 user guide will be useful to you.


FIELD CONTROLS 46091800 : Download the complete user guide (152 Ko)

Manual abstract: user guide FIELD CONTROLS 46091800

Detailed instructions for use are in the User's Guide.

[. . . ] The exit terminals of mechanical draft systems shall be not less than 7 feet above grade when located adjacent to public walkways. A venting system shall terminate at least 3 feet above any forced air inlet located within 10 feet. [. . . ] The venting system of other than a direct vent appliance shall terminate at least 4 feet below, 4 feet horizontally from or 1 foot above any door, window or gravity air inlet into any building. The vent termination of a direct vent appliance with an input of 50, 000 BTU per hour or less shall be located at least 9 inches from any opening through which vent gases could enter a building, and such an appliance with an input over 50, 000 BTU per hour shall require a 12-inch vent termination clearance. The bottom of the vent terminal and any air intake shall be located at least 12 inches above grade. Power venter should be located as close as possible to the outside wall. Forced draft systems and all portions of induced draft systems under positive pressure during operation shall be designed and installed so as to prevent leakage of vent gases into building. The vent termination point shall not be installed closer than 3 feet from an inside corner of an L-shaped structure, or not less than 12 inches above grade. Fasten wall end plate to the inside wall with appropriate type mounting screws. Install a properly sized vent pipe section into inner pipe of the vent hood. Seal the connection and all other vent pipe joints on the pressure side of the Power Venter with a high temperature silicone adhesive sealant or equivalent. Fasten vent pipe connection with three sheet metal screws or with other appropriate type mounting screws. MAINTENANCE The vent system should be inspected regularly at 3-month intervals. Screened opening of vent hood should be free from foreign material and cleaned if necessary. [. . . ] MAINTENANCE The vent system should be inspected regularly at 3-month intervals. Screened opening of vent hood should be free from foreign material and cleaned if necessary. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46091800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46091800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.