User manual FIELD CONTROLS 01986800

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIELD CONTROLS 01986800. We hope that this FIELD CONTROLS 01986800 user guide will be useful to you.


FIELD CONTROLS 01986800 : Download the complete user guide (39 Ko)

Manual abstract: user guide FIELD CONTROLS 01986800

Detailed instructions for use are in the User's Guide.

[. . . ] length of 12-2 wire 1) 12 inch jumper wire 1) Flexible conduit connector 2) GSK-3 Spillage Switch DO NOT DESTROY THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT CAUTION: Draft inducers are designed to increase draft in venting applications where inadequate natural draft exists. The vent to which the inducer is to be mounted is to be installed in accordance with NFPA 54, NFPA 31, or other local codes. This device MUST be installed by a qualified installer in accordance with the manufacturers installation instructions. [. . . ] Appliances should have a maximum measure flue gas temperature of 750°F at the desired location of the draft inducer. "Qualified Installer" shall mean an individual who has been properly trained or a licensed installer. The installer MUST write or imprint his name, phone number, and date of installation on the tag provided with this device. Recording burner and draft inducer operation information (draft level, efficiency, etc) is recommended as a guide for future service. I. INSTALL THE DI-SERIES DRAFT INDUCER ON THE FLUE PIPE (Figure 1) 1. Set the draft adjustment plate on the draft inducer to maximum setting before installing NOTE: The draft inducer proving switch (DIP-1) and DI-CK Control Kit adapter kit are not required with the DI PAK MV and MVFG kits. II. INSTALLATION OF GAS PRESSURE SWITCH CAUTION: Check gas control valve pressure. (See Figure 2) NOTE: If installing on an existing appliance, shut off gas supply to gas valve before plug removal. Replace the pressure tap plug with the 1/8" pipe nipple and pipe tee. All line voltage and safety control circuits, between the venter and the appliance, must be wired in accordance with the National Electrical Code for class one wiring or equivalent methods. Route the draft inducer motor and control wiring with an appropriate wiring method. Refer to the draft inducer installation instructions for setting system airflow to the maximum setting. Diagram A V. SYSTEM CONTROL CHECK OUT PROCEDURES GAS PRESSURE SWITCH FOR WATER HEATER 1. Then adjust the thermostat to call for heat, which will energize the venter motor. Turn gas control valve to the PILOT position, which will start a 1 to 3 min. Allow the water heater to heat up to operating temperature, then disconnect the power to the gas pressure switch. Allow approximately 2 minutes of flue gas spillage for the spillage switches to sense the spillage and disrupt the thermocouple circuit, halting the gas flow to the pilot and burner. [. . . ] Allow the water heater to heat up to operating temperature, then disconnect the power to the gas pressure switch. Allow approximately 2 minutes of flue gas spillage for the spillage switches to sense the spillage and disrupt the thermocouple circuit, halting the gas flow to the pilot and burner. Reset the spillage switches and light the pilot, then perform a second safety spillage test (Steps 1 and 2). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 01986800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 01986800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.