User manual FBII XL4600DL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FBII XL4600DL. We hope that this FBII XL4600DL user guide will be useful to you.


FBII XL4600DL : Download the complete user guide (449 Ko)

Manual abstract: user guide FBII XL4600DL

Detailed instructions for use are in the User's Guide.

[. . . ] The second line of this display can be programmed by your installer to contain customized descriptors for the areas of protection within your location. Throughout this users manual the following conventions are used to display the keystrokes required to perform the functions. [USER] 2. ARMING THE SYSTEM ARMING the system will activate all portions of your Security System. For example, if a protected door is open the system cannot be armed. SYSTEM READY The system is ready to be armed if the READY indicator light ON. [. . . ] LCD keypads will reflect the current system status through the indicator lights as follows; Fast blinking. TROUBLE Slow pulse NOT READY Solid ON Burglary alarms will be indicated with a STEADY sound through the keypad while FIRE alarms will generate a pulsing sound. LCD keypads will show the alarm conditions with a display as follows: fiELzy This display shows the zones in alarm. After entry of your four digit user code the following display will appear: -1 If an Intrusion has taken place while you were ayay, do not enter until the location has been securedlll. >> To clear the display of the alarm or trouble conditions audible signal enter [USER] again. and silence the 4. STAY The STAY mode is another way to ARM your system while you remain in the location. The STAY mode will deactivate any interior protection zones which means that you will be free to walk throughout your location without activating the alarm system. STAY PROCEDURE: STAY [USEQ Depress the STAY key followed by your user code. In addition, on LED keypads the STAY indicator will be lit. In LCD keypads the following display will appear; pi51 In the STAY mode only themeter burglary protection is active. You are free to walk around the residence without activating any of the interior protection zones. >> Remember, you must DISARM the system to when you want to leave the premise. Note: The STAY option will automatically be reset after the system is disarmed. 5. INSTANT The INSTANT mode arms the system and eliminates the entry time delay interval. This mode could be used if anyone enters through an entry/exit zone the alarm system will instantly activate. INSTANT PROCEDURE: INSTANT [USER] "i Depress the INSTANT key followed by your user code. Upon successful INSTANT ARMING of the system the ARMED Indicator will be lit. LCD keypads will contain the following message; rT Note: The INSTANT option will automatically be reset after the system Is disarmed. 6. INSTANT - STAY The INSTANT STAY mode will arm the system with the characteristics of both the INSTANT and STAY modes. The system will be armed with the interior portions bypassed and the entry delay will be suspended. PROCEDURE: INSTANT-STAY [USER] STAY kSTANT [USER] Depress the INSTANT and STAY keys in any order followed by your user code. After a successful INSTANT STAY arming the ARMED indicator will be, lit. In addition, on LED keypads both the INSTANT and STAY lights will be on. BYPASS . 1 !T Bypasses are performed to eliminate burglary zones that are not ready or fab. , ' . BYPASS PROCEDURE: BYPASS [USER] ZN Depress the BYPASS key followed by your user code and zone number (4-6) to be bypassed. BY PASS [USER] 2 If the zone has already been bypassed, the sequence will unbypass the zone except if the system is armed and the unbypassed zone is still not ready. After the bypass (or unbypass) command has been accepted the unit will emit a continuous beep and zone or zones that have been bypassed will appear In a slow blinking mode In the zone status area on LED keypads. LCD keypads will display the zone bypasses as a secondary display after the SYSTEM READY or SYSTEM NOT READY as shown below: If multiple zones are bypassed then more than one display will appear. 8. UNBYPASS The UNBYPASS function removes an existing bypass from a currently bypassed zone. [. . . ] QUICK FORCED ARMING Another optlon selectable by your installer is a QUICK FORCED ARMING feature. If this feature has been selected then depression of the # key followed by 2 will ARM the system without need for entry of a user code and will bypass any burglary zones that are not ready. NOTE: System disarming will still require entry of a valid user code. . 14. INSTALLATION LAYOUT Early warning fire detection is best achieved by the lnstallatlon of fire detection equipment the location as follows: Typical Smoke Detector ~Pmposed) Layout Preparation of an evacuation plan is of prime importance in fire prevention. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FBII XL4600DL




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FBII XL4600DL will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.