User manual FBII LEGEND-LED

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FBII LEGEND-LED. We hope that this FBII LEGEND-LED user guide will be useful to you.


FBII LEGEND-LED : Download the complete user guide (165 Ko)

Manual abstract: user guide FBII LEGEND-LED

Detailed instructions for use are in the User's Guide.

[. . . ] 5- COMMUNICATIONS FAILURE 13 If the COM light is ON then there has been a communications error with the Central Station. 6- INSTANT The INS indicator will be ON when the system has been armed in the INSTANT mode. This means that the system has been activated and the entry delay has been eliminated. 7- NUMERICAL SECTION The numerical section of the keypad operates similar to a calculator or typewriter. [. . . ] If the system is ready, ARMING can be performed as follows; ARMING PROCEDURE 1. Enter your four digit user code into the keypad: [USER] The ARMED indicator light will now be lit and if you are leaving the home you may exit through a door designated by your installer as an exit/entry zone for a fixed time period known as the exit delay. SYSTEM NOT READY If the system is not ready to be armed the READY indicator will be OFF. The zone indicator lights will display the zones which are currently not ready. The condition of each zone indicator reflects what the status of each zone as follows; ALARM Fast blinking BYPASS Slow blinking low intensity. TROUBLE Slow pulse NOT READY Solid ON In order to make the system ready ready determine which zones are not ready by observing the zone indicator lights. From the zone number you can find out which area of protection is not ready. 7 >> Once the problems with each zone has been resolved the READY light will appear and the system can be armed. To arm the system in this situation one of the following actions are necessary; - Make the zone(s) ready. Determine which zones are not ready and perform what is necessary to ready the zone(s) (example, close the door or window, etc), or - Bypass the zone(s) not ready. Bypassing should only be performed if the zone cannot be made ready or intentionally will remain not ready. Remember, zones that are bypassed are not protected when the system is armed. STAY The STAY mode is another way to ARM your system while you remain in the location. The STAY mode will deactivate any interior protection zones which means that you will be free to walk throughout your location without activating the alarm system. STAY PROCEDURE: STAY [USER] Depress the STAY key followed by your user code. After a sucessful STAY arming the ARMED and STAY indicator will be lit. In the STAY mode only the external or perimeter burglary protection is active. You are free to walk around the residence without activating any of the interior protection zones. >> Remember, you must DISARM the system to when you want to leave the premise. Note: The STAY option will automatically be reset after the system is disarmed. 8 BYPASS INSTANT The INSTANT mode arms the system and eliminates the entry time delay interval. [. . . ] After UNBYPASSING a zone, the bypass indication will be removed from that zone. UNBYPASS PROCEDURE >> To clear the display of the alarm or trouble conditions and silence the audible signal enter [USER] again. 11 BYPASS [USER] ZN See bypass description. 12 KEYPAD EMERGENCY CONDITIONS In addition to individual zone alarms various conditions can be transmitted directly through the keypad. These conditions are initiated through the simultaneous depression of two keys, as shown below; Reset The DURESS signal is meant to disarm the system and transmit an emergency signal to the Central Station indicating that there is a problem. The DURESS capability must be enabled by your installer and can be initiated in one of two methods; - either by entry of user code #16 or - entry of a valid user code with the last digit altered by one. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FBII LEGEND-LED




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FBII LEGEND-LED will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.