User manual EXHAUSTO RSV

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EXHAUSTO RSV. We hope that this EXHAUSTO RSV user guide will be useful to you.


EXHAUSTO RSV : Download the complete user guide (1365 Ko)

Manual abstract: user guide EXHAUSTO RSV

Detailed instructions for use are in the User's Guide.

[. . . ] All installations must be carried out by competent personnel in accordance with national laws and regulations The chimney fan should always be switched on when the fireplace or boiler is in use · Please always read the installation instructions for the EXHAUSTO CDT control unit, before installation of the chimney fan. If this can not be achieved, then a smoke alarm must be installed in the same room as the appliance. EXHAUSTO CDT would always recommend the use of a smoke alarm when a solid fuel open fire is installed · Avoid build up of soot and tar use only well seasoned wood (moisture content max 20%) · Both types can be opened for service and maintenance. [. . . ] 3000113-2010-12-13 Before fitting onto a steel chimney Step 1 Action A flange (D) (supplied as extra) is used, fitted so that the spigot end sits inside the chimney (E). Place the mineral wool mat (B) on the flange (D) with the aluminium foil facing upwards and cut a hole in the mineral wool mat, the hole being the same diameter as the flange hole. Cut the corners of the mineral wool mat, so there is room to fit the vibration dampers (C). If a temperature sensor is to be installed with the chimney fan, cut the aluminium foil on the mineral wool mat to make room for the sensor; this also ensures that the mat sits level on the chimney. 4 Fit the flange to the chimney fan, with the use of the vibration dampers (C). 3000113-2010-12-13 Fitting the chimney fan onto the chimney Step 1 Action Attach the safety wire to the chimney (1). Use the screw and rawl plug provided in the brickwork of the chimney or the self-cutting screw if working on a steel chimney. Then fit the wire through the hole in the bottom section and into the wire clamp. Gently tighten the safety wire, and crimp (2) the wire clamp so that the fan is held safely in place when opened for servicing or cleaning purposes. The isolation switch (supplied as extra) should be fitted onto the side of the chimney (3), so it is easily accessible when servicing the fan. The armoured cable with connecting cable should be mounted into the underside of the isolator and up into the switch through the coupling. That the user is aware that the fan must always be switched on whenever the fireplace or boiler is in use · Any lightning conductor connected to the fan must respect current applicable legislation. : 3000194 In accordance with the provisions of the EU Machinery Directive* a combustion-gas fan must always have an isolation switch fitted. The isolation switch must be ordered separately, as it is not part of the standard EXHAUSTO CDT chimney fan delivery. GRUNDFOS FAN RSV009-4-1 brown = L 87104366 RSV009-41 RSV160-4-1 blue = Nreg. RSV160-41 yellow/green = 87104367 RS012-41 87104368 RSV012-41 RSV012-4-1 brown = L RS255-41 RSV014-4-1 blue = Nreg. [. . . ] At higher temperatures, though maximum 300°C, the mineral wool mat should be replaced with adjusting screws (type RSD) or vibration dampers (type SVD. EXHAUSTO CDT provides a two-year factory warranty on its flue gas fans, valid from invoice date. EXHAUSTO CDT reserves the right to introduce changes to these guidelines without prior notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EXHAUSTO RSV




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EXHAUSTO RSV will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.