User manual ENGENIUS MULTICOM III DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ENGENIUS MULTICOM III. We hope that this ENGENIUS MULTICOM III user guide will be useful to you.


ENGENIUS MULTICOM III DATASHEET: Download the complete user guide (67 Ko)

Manual abstract: user guide ENGENIUS MULTICOM IIIDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] MultiCom III/s Multi-Purpose Vehicle Interface Adapter for Serial Connection to PC EnGenius' MultiCom III/s is a flexible solution that provides simultaneous access to multiple vehicle networks as well as digital and analog input/output. [. . . ] Each PIM (standard or custom designed) contains the specific interface circuits that allow MultiCom III/s to connect to external devices. This multi-purpose vehicle interface adapter provides a powerful, yet flexible, solution to meet a wide range of needs. MultiCom III/s can be packaged in an optional 7. 75" x 5. 75" x 2. 75" aluminum enclosure. Base Platform Features 5 RS232, RS422, or RS485 serial connection to host (RS-232 up to 230K baud, RS-422/RS485 up to 1M baud) 5 3 Physical Interface Module (PIM) slots 5 ISO 9141 5 SAE J1850 PWM (using an HBCC) 5 7 channel 12 bit A/D inputs (2 for 5VDC, 2 for 20VDC, 2 are PIM accessible, and 1 is available for remote-sensing) 5 5­18 VDC 100mA software-controlled variable output voltage source 5 8 digital inputs 5 8 digital outputs 5 2 16552 UART channels are PIM accessible 5 9­18 VDC input required (1A max. ) with onboard isolated switching power supply for voltage regulation 5 40MHz 80C196NU microcontroller 5 128K RAM 5 256K Flash ROM 5 4" x 6" x 1" board size Interface Capabilities MultiCom III/s is capable of supporting ISO 9141, ISO 9141-2, ISO 14230, ISO 11519-4, ISO 15765, ISO 11898, SAE J1850 PWM, SAE J1850 VPW, CAN, SAE J2411, SAE J2284, Ford's DCL, RS485/RS422, Ford's UBP, SAE J1939, SAE J1708, and others (including custom protocols). Optional Physical Interface Modules 5 SAE J1850 PWM (using an HBCC) 5 SAE J1850 VPW (using an MC68HC56) 5 CAN (Single Wire, High Speed, and Fault Tolerant) 5 Ford's DCL 5 RS485/RS422 5 Ford's UBP 5 SAE J1939* 5 ISO 9141* 5 SAE J1708* * indicates PIM is under development Applications 5 5 5 5 5 5 5 Engineering development or in-vehicle use Protocol translation Network monitoring Module validation, test fixtures Diagnostics Heavy truck Light and medium duty vehicles Software & Documentation 5 User's manual provides a description of the hardware and application library interface 5 DLLs for 16 bit Windows 3. x 5 DLLs for 32 bit Windows 95/98/NT/2000/XP EnGenius · 31077 Schoolcraft Rd. · Livonia, MI 48150-2029 · (734) 522-2120 · www. engenius. com 06/02/05 Technical Data for MultiCom III/s Physical Interface Modules ISO 9141 5 5 5 5 5 5 5 5 K and L line support 5­115. 2K baud supported Selectable line termination Timestamping available with byte stream or ISO 9141-2 message modes Configurable inter-byte and inter-message times Configurable timed interval transmission of up to 10 user-defined messages Jumper selectable ISO 9141 circuit voltage (on-board or external) Software configurable loop back CAN 5 Uses Intel's 82527 with either Single Wire, High Speed, or Fault Tolerant transceiver 5 15, 625-1M baud supported 5 Configurable 11 and 29 bit CAN identifiers 5 Selectable line termination 5 Message timestamping 5 Configurable message filtering at the board level 5 Configurable inter-message times 5 Configurable timed interval transmission of up to 10 user-defined messages 5 12 configurable remote transmit objects SAE J1850 PWM 5 Uses Ford/Motorola Hosted Bus Controller Chip (HBCC) 5 10. 4K, 20. 8K, 41. 6K, and 83. 3K baud supported 5 Selectable line termination 5 Message timestamping 5 Configurable inter-message times 5 Configurable timed interval transmission of up to 10 user-defined messages Ford's DCL 5 Uses 16552 Dual UART 5 2. 4K, 4. 8K, 9. 6K, and 19. 2K baud supported 5 Link master, link slave, and UART stream modes supported 5 Byte stream or frame timestamping 5 Automatic Frame parsing with vertical parity nibble validation for link master or link slave modes 5 Software configurable loop back for UART stream mode SAE J1850 VPW 5 5 5 5 5 Uses Motorola's MC68HC56 10. 4K and 41. 6K baud supported Selectable line termination Message timestamping Configurable message filtering at the board level 5 Configurable inter-message times 5 Configurable timed interval transmission of up to 10 user-defined messages 5 Software configurable loop back RS485/RS422 5 Uses 16552 Dual UART 5 2. 4K, 4. 8K, 9. 6K, and 19. 2K baud supported (Other data rates available. ) 5 Byte stream timestamping 5 Software configurable loop back Ford's UBP 5 5 5 5 5 Uses Ford's recommended discrete circuit Selectable line termination Message timestamping Configurable inter-message times Configurable timed interval transmission of up to 10 user-defined messages 5 Software configurable loop back 5 Supports up to 255 data bytes per message 5 Supports a completely passive monitor mode EnGenius · 31077 Schoolcraft Rd. [. . . ] · Livonia, MI 48150-2029 · (734) 522-2120 · www. engenius. com 06/02/05 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ENGENIUS MULTICOM III




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ENGENIUS MULTICOM III will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.