Detailed instructions for use are in the User's Guide.
[. . . ] · If the LED status indicator does not light up when the charger is plugged into either supplied power adapter, recheck the connections and make sure that the AC socket or cigarette lighter has power. · If the battery is attached, and the status indicator is
unit and check that the battery is attached correctly. Also, make sure the adapter plate is the proper one and that it is securely attached to the charger base.
ESTIMATED BATTERY CHARGE TIMES:
BATTERY CAPACITY TIME TO MAX CHARGE*
· Use clean dry cloth when necessary to keep the metal contacts of both charger and battery clean.
Note: Batteries will self discharge when not in use whether they are installed in a camcorder, digital camera or not. [. . . ] While pressing down lightly on the adapter plate, slide the plate toward the front of the charger base until it locks (see Figure 2).
FITS: ENERGIZER - ER-C535, ER-C540, ER-C557, ER-C735, ER-C745 PANASONIC - CGR-DU07, CGR-DU14, CGR-DU21 SONY - NP-FP50, NP-FP70, NP-FP90 SHARP - BT-L226 SAMSUNG - SB-L70G
Diagram 2 Phase I
Note: When the battery is first connected, the LED's may instantly indicate MED, HI or MAX charge depending on the charge status of the battery. Note: It is normal for the charger, AC adapter, or the battery to become warm during charging.
Plug-in, either the AC Adapter or the DC Cigarette Lighter power adapter, and connect the other end of the power adapter cable to the power input jack on the rear of the charger unit.
Phase II MED Charge: The MED LED is on continuously
and other LED's are flashing in sequence (see diagram 3). Some very small capacity batteries (650mAh) and worn out batteries can be as low as 10% charged.
Status LED's
Together, the three LED's on the front of the ER-CH2 charger will indicate the status of the battery and the charger. See the descriptions and diagrams included in the following sections regarding the various indications and their meaning.
FITS: CANON - BP-508, BP-511, BP-512, BP-522 ENERGIZER - ER-C590, ER-C600
Diagram 3 Phase II
Phase III HI Charge: The MED and HI LED's are on and the
MAX LED is flashing (see diagram 4). At this point the battery is typically, about 70% charged.
CHARGING YOUR BATTERY
StandBy Mode: Without any battery installed, the charger will
flash the LED on the left, marked MED, indicating that the charger is standing by and waiting for a battery to be connected (see diagram 1).
Diagram 4 Phase III
Diagram 1 Standby
FITS: ENERGIZER - ER-C520, ER-C544, ER-C545, ER-C571, ER-C640, ER-C610 HITACHI- VM-BPL13A, VM-BPL27A, VM-BP30A, VM-BPL60A SONY - NP-F550, NP-F750, NP-FM50, NP-FM70, NP-FM90 PANASONIC - VW-VBD1
Flashing MED
Off HI
Off MAX
Charge Complete MAX Charge: All three LED's are on at
the same time (see diagram 5). It is recommended to remove the battery at this time.
Once a battery has been properly connected to the appropriate adapter plate, the charger will determine the status of the battery and begin the proper phase of the charging cycle. The battery may be removed during any of the charging phases without harm to the battery or charger unit.
Diagram 5 Complete
Limited 3 Year Warranty
The Error Condition will also be indicated if the charger senses any problem with the battery being charged. To reset the error condition, unplug the charger from the power adapter for a few seconds, then reconnect it to the power adapter. If the Error occurs again, there may be a defect in the battery that will prevent safely charging.
showing "Stand By" (indicated by the MED light flashing and all other lights off), the battery may not be making proper contact to the adapter plate. Unplug the
This limited warranty starts from the date of original purchase and expires 3 years thereafter. If, during this period, any part because of manufacturing defects or workmanship fails to function properly under normal use, it will be repaired at no charge for parts and labor or, at our option, the product will be replaced. The following is excluded:damages from delay or loss of use of equipment, or damaged batteries, malfunctions resulting from misuse, tampering, unauthorized repairs, modifications, or accident.
Diagram 6 Error
On MED
Off HI
On MAX
When sending in product for service, your package should include evidence of date and place of purchase. Package the unit and its accessories carefully using ample padding material to prevent damage in transit and ship it prepaid and insured to:
Sequential Flashing
MED
On MED
On MED
On MED
Technuity, Inc. 79th Street Indianapolis, IN 46278
removed before a complete charge has been reached, the charger will continue indicating the last complete charging phase for up to 1 minute. [. . . ] · Use this charger with the power adapters included in the package only. · It is not necessary or recommended to discharge a Li-Ion prior to charge. · No user serviceable parts, opening chassis will void warranty.
For additional questions, comments or to explore other Energizer battery solutions, visit our web site at: www. energizerbatteries. com or call us at 800-887-2557
Sequential Flashing Sequential Flashing
Error Condition - Charge Terminated: If the battery is
TROUBLE SHOOTING TIPS:
CAUTIONS:
HI
MAX
Sequential Flashing
Sequential Flashing
HI
MAX
On HI
Flashing MAX
On HI
On MAX [. . . ]