User manual ENERGIZER ER-CH1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ENERGIZER ER-CH1. We hope that this ENERGIZER ER-CH1 user guide will be useful to you.


ENERGIZER ER-CH1 : Download the complete user guide (856 Ko)

Manual abstract: user guide ENERGIZER ER-CH1

Detailed instructions for use are in the User's Guide.

[. . . ] ESTIMATED BATTERY CHARGE TIMES: BATTERY CAPACITY TIME TO MAX CHARGE* 750 mAh 1200 mAh 1500 mAh 1850 mAh 2400 mAh 3700 mAh 5550 mAh 30 minutes 39 minutes 50 minutes 65 minutes 80 minutes 110 minutes 195 minutes * Actual charge times may vary depending on the battery, internal protection circuits, cell capacity and condition. TROUBLE SHOOTING TIPS: · Batteries should be replaced when runtime becomes short. · If the LED status indicator does not light up when the charger is plugged into either supplied power adapter, recheck the connections and make sure that the AC socket or cigarette lighter has power. · If the battery is attached, and the status indicator is showing "Stand By" (indicated by the MED light flashing and all other Note: Batteries will self discharge when not in use whether they are installed in a camcorder, digital camera or not. [. . . ] Some very small capacity batteries (650mAh) and worn out batteries can be as low as 10% charged. Status LED's Together, the three LED's on the front of the ER-CH1 charger will indicate the status of the battery and the charger. See the descriptions and diagrams included in the following sections regarding the various indications and their meaning. Diagram 3 Phase II OPERATION Getting Ready Choose the adapter plate for the type of Li-Ion (Lithium-Ion) battery you will be charging. Each of the adapter plates is labeled as to the batteries it can work with. If the charger base does not already have the adapter plate you want attached, you will need to remove the adapter plate first by pushing down on the plate and sliding it to the rear of the charger base (away from the LED indicators). Then, attach the selected adapter plate to the charger unit by aligning the slots on the adapter plate bottom with the fingers on the charger base. While pressing down lightly on the adapter plate, slide the plate toward the front of the charger base until it locks (see figure 1). CHARGING YOUR BATTERY StandBy Mode: Without any battery installed, the charger will flash the LED on the left, marked MED, indicating that the charger is standing by and waiting for a battery to be connected (see diagram 1). Phase III ­ HI Charge: The MED and HI LED's are on and the MAX LED is flashing (see diagram 4). At this point the battery is typically, about 70% charged. Diagram 1 Standby Flashing MED Off HI Off MAX Diagram 4 Phase III Charge Complete ­ MAX Charge: All three LED's are on at the same time (see diagram 5). It is recommended to remove the battery at this time. Once a battery has been properly connected to the appropriate adapter plate, the charger will determine the status of the battery and begin the proper phase of the charging cycle. The battery may be removed during any of the charging phases without harm to the battery or charger unit. Diagram 5 Complete This limited warranty starts from the date of original purchase and expires 3 years thereafter. If, during this period, any part because of manufacturing defects or workmanship fails to function properly under normal use, it will be repaired at no charge for parts and labor or, at our option, the product will be replaced. The following is excluded:damages from delay or loss of use of equipment, or damaged batteries, malfunctions resulting from misuse, tampering, unauthorized repairs, modifications, or accident. The Error Condition will also be indicated if the charger senses any problem with the battery being charged. To reset the error condition, unplug the charger from the power adapter for a few seconds, then reconnect it to the power adapter. If the Error occurs again, there may be a defect in the battery that will prevent safely charging. Limited 3 Year Warranty · For use with 7. 2 ­ 7. 4V Lithium-Ion (Li-Ion) batteries ONLY!Use with other type batteries voids warranty, may cause damage to the charger/battery and possibly cause injury to the user. · For best battery life, we suggest recharging Li-Ion batteries after use and before storage. · Do not leave battery connected to camcorder or camera when not in use. [. . . ] Also, make sure the adapter plate is the proper one and that it is securely attached to the charger base. · Use a clean dry cloth when necessary to keep the metal contacts of both charger and battery clean. MED On MED On MED On MED Technuity, Inc. 86th Street, Suite 289 Indianapolis, IN 46240 Sequential Flashing Sequential Flashing HI MAX Sequential Flashing Sequential Flashing HI MAX On HI Flashing MAX On HI On MAX [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ENERGIZER ER-CH1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ENERGIZER ER-CH1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.