User manual ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP. We hope that this ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP user guide will be useful to you.


ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP : Download the complete user guide (2938 Ko)

Manual abstract: user guide ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions Proline t-mass 65 PROFIBUS DP Thermal Mass Flow Measuring System 8 BA113D/06/en/02. 06 71021608 Valid as of version V 3. 02. XX (Device software) Proline t-mass 65 PROFIBUS DP Table of contents Table of contents 1 1. 1 1. 2 1. 3 1. 4 1. 5 Safety instructions . 29 29 30 31 31 32 32 32 32 33 34 35 4. 2 2 2. 1 Identification . 11 11 11 11 12 12 12 13 14 16 16 17 17 18 19 22 23 23 23 24 24 25 25 25 27 28 5 5. 1 5. 2 Operation . 36 37 37 37 38 39 39 39 40 40 40 41 41 41 41 42 43 43 44 45 3. 2 5. 3 5. 4 5. 5 5. 6 3. 3 3. 4 3 Proline t-mass 65 PROFIBUS DP Table of contents 6 6. 1 6. 2 6. 3 Commissioning . [. . . ] Select the option MASS FLOW Possible setting Totalizer value / measured variable MASS FLOW (factory setting totalizer 1 to 2) CORR. the PROFIBUS network configuration, the module or the function "TOTAL" was integrated in slot 4 or 5, If, when the measured variable selected in the CHANNEL function is transmitted cyclically to the PROFIBUS Master (class 1) for the respective totalizer 1 to 2 ( Page 59). Enter the desired unit for the totalizer: TOTALIZER UNIT TOTALIZER Configure totalizer status (e. g. totalize): TOTALIZER SET TOTALIZER Option: TOTALIZE Set the totalizer mode: TOTALIZER MODE TOTALIZER: Select one of the following options: BALANCE (factory setting): calculates the positive and negative flow portions. The device can't calculate negative flow portions. 53 Commissioning Proline t-mass 65 PROFIBUS DP 7. Select the operating mode: Select the operating mode (GSD file) which should be used for cyclic data transmission with the PROFIBUS Master. COMMUNICATION SELECTION GSD Selection of one of the following options: MANUFACT. PROFILE-GSD: The device is operated in the PROFIBUS Profile mode. ! Note!For PROFIBUS network configuration, make sure that the right device master file (GSD file) of the measuring device is used for the selected operating mode Page 54 ff. Configuration of cyclic data transmission in the PROFIBUS master: A detailed description of the cyclic data transmission is contained on Page 57 ff. 6. 5 6. 5. 1 PROFIBUS DP system integration Device master file (GSD file) For PROFIBUS network configuration, the device master file (GSD file) is needed for every bus participant (PROFIBUS slave). The GSD file contains a description of the properties of a PROFIBUS device, such as supported data transmission rate and number of input and output data. Before configuration takes place, a decision should be made as to which GSD file should be used to operate the measuring device in the PROFIBUS DP Master (class 1) system. The measuring device supports the following GSD files: t-mass GSD file (manufacturer-specific GSD file, complete device functionality) PROFIBUS Profile GSD file: Below you will find a detailed description of the GSD files supported. t-mass GSD file (manufacturer-specific GSD file, complete device functionality) Use this GSD file to access the complete functionality of the measuring device. In this way, devicespecific measured variables and functions are thus completely available in the PROFIBUS master system. An overview of the modules available (input and output data) is contained on Page 57 ff. GSD file with standard or extended format The GSD file with either the standard or the extended format must be used depending on the PROFIBUS Master used. When installing the GSD file, the GSD file with the extended format (EH3x15xx. gsd) should always be used first. However, if the installation or the configuration of the measuring device fails with this format, then use the standard GSD (EH3_15xx. gsd). This differentiation is the result of different implementation of the GSD formats in the master systems. PROFIBUS DP 1545 (Hex) GSD file Bitmaps Extended Format (recommended): EH3x1545. gsd EH_1545_d. bmp/. dib Standard Format: EH3_1545. gsd EH_1545_n. bmp/. dib EH_1545_s. bmp/. dib Source Internet (Endress+Hauser) www. endress. com ( Download Software Device Drivers) CD-ROM with all GSD files for Endress+Hauser devices Order No. : 56003894 54 Proline t-mass 65 PROFIBUS DP Commissioning Contents of the download file from the Internet and the CD-ROM All Endress+Hauser GSD files (standard and extended format) Endress+Hauser bitmap files Useful information relating to the devices PROFIBUS Profile GSD file: The function scope of the profile GSD file is defined by the PROFIBUS Profile Specification 3. 0. The function scope is restricted compared to the manufacturer-specific GSD file (complete device functionality). However, similar devices from different manufacturers can be interchanged with the profile GSD file without the need to reconfigure (interchangeability). The following modules are supported with the Profile GSD file: "AI Flow" module Analog Input function block 1/output variable: mass flow "Totalizer" module Totalizer function block 1/output variable: totalized mass flow Name of the PROFIBUS Profile GSD file ID No. [. . . ] The measuring system meets the EMC requirements of the Australian Communications and Media Authority (ACMA). EN 60529: Degrees of protection by housing (IP code) EN 61010-1 Protection Measures for Electrical Equipment for Measurement, Control, Regulation and Laboratory Procedures. EN 61326/A1 (IEC 1326) "Emission in accordance with requirements for Class A". Electromagnetic compatibility (EMCrequirements) NAMUR NE 21: Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ENDRESS+HAUSER PROLINE T-MASS 65 PROFIBUS DP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.