If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EMERSON FANS STURBRIDGE. We hope that this EMERSON FANS STURBRIDGE user guide will be useful to you.
Manual abstract: user guide EMERSON FANS STURBRIDGE
Detailed instructions for use are in the User's Guide.
[. . . ] READ AND SAVE THESE INSTRUCTIONS
Emerson Fans
Designed by
STURBRIDGE
Ceiling Fan Owner's Manual
Model Numbers
KF180AP00
Antique Pewter with Natural Cherry/Mahogany Blades
KF180OZ00
Olde Bronze¨ with Teak/Natural Pine Blades
KF180DBK00
Distressed Black with Distressed Black/Natural Cherry Blades
Net Weight: 30. 9 Lbs.
Part No. BP7284
!
WARNING
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Tools Needed for Assembly
One Phillips head screwdriver One wire stripper One stepladder Six wire connectors (supplied)
Safety Instructions
1. Read your owner's manual carefully and keep it for future reference. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. [. . . ] Position the pin
6
Figure 5
How to Hang Your Ceiling Fan
!
How to Wire Your Ceiling Fan
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
HANGER BRACKET TAB
WARNING
The fan must be hung with at least 7' of clearance from floor to blades (Figure 9).
CEILING
OUTLET BOX TWO SCREWS SUPPLIED WITH OUTLET BOX
!
WARNING
Figure 10
AT LEAST 7'
FLOOR
Figure 9 !
2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 11). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 10). To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver. Position the supply wires to the left side of the outlet box (Figure 12); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 12. Make sure that all connections are tight, including ground, and that no bare wire
SUPPLY WHITE WIRE (NEUTRAL)
WARNING
WARNING
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. !
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
NOTE: CEILING COVER, SUPPL WIRES AND FAN Y WIRES OMITTED FOR CLARITY. OUTLET BOX
is visible at the wire connectors, except for the ground wire. Refer to Figure 12 and 13 and connect the receiver wires to the supply wires and the fan motor wires as follows: a. Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor (this may be a bare wire or a wire with green insulation). Securely connect the supply white (neutral) wire to the receiver white (AC IN N) wire. Securely connect the supply black wire (hot) wire to the receiver black (AC IN L) wire. Securely connect the fan motor white wire to the receiver white (TO MOTOR N) wire. Securely connect the fan motor black wire to the receiver red (TO MOTOR L) wire. Securely connect the fan motor blue wire to the receiver blue (FOR LIGHT) wire. !
WARNING
WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked "Acceptable for Fan Support", and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 10). !
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. [. . . ] You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. Repair and replacement of defective parts on the light fixture housing or electronics (excluding the lamp) for two years from the date of purchase. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. [. . . ]