User manual EMERSON FANS ODYSSEY

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EMERSON FANS ODYSSEY. We hope that this EMERSON FANS ODYSSEY user guide will be useful to you.


EMERSON FANS ODYSSEY : Download the complete user guide (349 Ko)

Manual abstract: user guide EMERSON FANS ODYSSEY

Detailed instructions for use are in the User's Guide.

[. . . ] READ AND SAVE THESE INSTRUCTIONS Model No. CF2454WW02 CF2454BS02 CF2454PW02 CF2454BQ02 Net Weight: 26. 0 Lbs. ® THE ODYSSEY Series Ceiling Fan Owner's Manual Part No. BP7211-8 ! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner's manual carefully and keep it for future reference 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. [. . . ] Using the wire connector supplied, connect the uplight yellow lead assembly to the yellow lead from the fan motor and housing assembly. 4" UPLIGHT YELLOW LEAD ASSEMBLY CUT HERE HANGER BRACKET SW375 RECEIVER OPEN SIDE HANGER BALL DOWNROD 3" Figure 19 FLAT SIDE CEILING COVER Figure 17 7. Fold the yellow wire into the slot in the motor coupling, slide the downrod down the wires and seat the downrod in the motor coupling (Figure 20). Align the clevis pin holes in the downrod with the holes in the motor coupling. The clevis pin must go through the holes in the motor coupling and the holes in the downrod . Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed. 8 ! WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. NOTE: Make sure the red and brown leads are capped with wire connectors. Make sure red, brown, and yellow wire connectors are completely inside motor coupling cover and not pinched between the motor coupling cover and motor. KNURLED KNOB MOTOR COUPLING COVER WIRE CONNECTOR YELLOW LEADS 1-1/4" THREADED STUD 7/8" YELLOW LEADS TO BE POSITIONED IN SLOT IN MOTOR COUPLING SETSCREW WIRE CONNECTORS DOWNROD HAIRPIN CLIP MOTOR COUPLING RED LEAD BROWN LEAD MOTOR BRACKET CLEVIS PIN Figure 22 11. Be sure the cover is oriented correctly, with the large opening at the top (Figure 23). Route the motor leads through the hanger ball and slide the hanger ball over the downrod (Figure 23). Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble. ! DOWNROD HAIRPIN CLIP CLEVIS PIN CLEVIS PIN MOTOR COUPLING Figure 20 9. Install the setscrew (supplied in loose parts bag) in the motor coupling and tighten using the 5/32" setscrew wrench (supplied) (Figure 21). WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling. DOWNROD PIN HANGER BALL SETSCREW CEILING COVER DOWNROD SETSCREW Figure 21 10. Screw two 1-1/4" threaded studs (provided) into the motor (Figure 22). Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude; install two knurled knobs (supplied) to secure the cover. Figure 23 13. The blue, black, yellow and white leads exiting the downrod are 80-inches long. Before installing fan, measure up approximately 6 to 9-inches above the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads. NOTE: If you are installing your fan with a SR330 Remote Control or SW350 Wall Control, Do Not Cut Terminal Off of the Yellow Lead. [. . . ] For repair parts, phone 1-800-654-3545. 15 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EMERSON FANS ODYSSEY




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EMERSON FANS ODYSSEY will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.