User manual EMERSON FANS LORRAINE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EMERSON FANS LORRAINE. We hope that this EMERSON FANS LORRAINE user guide will be useful to you.


EMERSON FANS LORRAINE : Download the complete user guide (492 Ko)

Manual abstract: user guide EMERSON FANS LORRAINE

Detailed instructions for use are in the User's Guide.

[. . . ] BP7308 LORRAINE KF240 2/15/06 3:21 PM Page 1 READ AND SAVE THESE INSTRUCTIONS Emerson Fans Designed by LORRAINE Ceiling Fan Owner's Manual Model Number KF240PRZ00 Parisian Bronze with Dark Cherry/Walnut Blades Net Weight: 27. 0 Lbs. Part No. BP7308 BP7308 LORRAINE KF240 2/15/06 3:21 PM Page 2 ! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner's manual carefully and keep it for future reference. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. [. . . ] All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver. Position the supply wires to the left side of the outlet box (Figure 14); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 14. Make sure that all connections are tight, SUPPLY WHITE WIRE (NEUTRAL) including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Refer to Figures 14 and 15 and connect the receiver wires to the supply wires and the fan motor wires as follows: a. Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor (this may be a bare wire or a wire with green insulation). Securely connect the supply white (neutral) wire to the receiver white (AC IN N) wire. Securely connect the supply black wire (hot) wire to the receiver black (AC IN L) wire. Securely connect the fan motor white wire to the receiver white (TO MOTOR N) wire. Securely connect the fan motor black wire to the receiver red (TO MOTOR L) wire. Securely connect the fan motor blue wire to the receiver blue (FOR LIGHT) wire. ! WARNING Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Noise and fan damage could result. RECEIVER WHITE WIRE RECEIVER BLACK WIRE AC IN SUPPLY BLACK WIRE (HOT) GROUND WIRE N RECEIVER RED WIRE RECEIVER BLUE WIRE TO MO ANTENNA GREEN GROUND WIRE FROM HANGER BRACKET 1-1/4" THREADED STUD (2) FAN BLACK WIRE FAN BLUE WIRE FAN WHITE WIRE RECEIVER WHITE WIRE Figure 14 11 FOR LI GREEN GROUND WIRE FROM HANGER BALL TOR N AC IN L GHT TO M OTO RL BP7308 LORRAINE KF240 2/15/06 3:21 PM Page 12 SW101 FAN/LIGHT WALL CONTROL (SUPPLIED) TO 120VOLT SUPPLY BLACK (HOT) OFF BLACK HI LIGHT MED BLACK WHITE WHITE RED LOW FAN OFF EMERSON® ON WHITE GROUND TWO-CONDUCTOR CABLE (WITH GROUND) GREEN WIRE (GROUND) FROM HANGER BALL AND HANGER BRACKET BLUE BLACK BLUE WHITE WHITE Figure 15 3. Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket. Screw the two 1-1/4" threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 14). Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 16). Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling. CEILING COVER HANGER BALL ! WARNING To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling. Screw in three 40-watt (maximum) candelabra bulbs in the light fitter sockets (Figure 17). Carefully place the lower glass over the light fitter threaded nipple. Be sure the glass is firmly seated on the fitter, then secure in place using a rubber washer, metal washer, and 1/8-27 nut (washers and nut are supplied). [. . . ] You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EMERSON FANS LORRAINE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EMERSON FANS LORRAINE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.