If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EMERSON FANS LORRAINE. We hope that this EMERSON FANS LORRAINE user guide will be useful to you.
Manual abstract: user guide EMERSON FANS LORRAINE
Detailed instructions for use are in the User's Guide.
[. . . ] BP7308 LORRAINE KF240
2/15/06
3:21 PM
Page 1
READ AND SAVE THESE INSTRUCTIONS
Emerson Fans
Designed by
LORRAINE
Ceiling Fan Owner's Manual
Model Number
KF240PRZ00
Parisian Bronze with Dark Cherry/Walnut Blades
Net Weight:
27. 0
Lbs.
Part No. BP7308
BP7308 LORRAINE KF240
2/15/06
3:21 PM
Page 2
!
WARNING
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner's manual carefully and keep it for future reference. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. [. . . ] All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver. Position the supply wires to the left side of the outlet box (Figure 14); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 14. Make sure that all connections are tight,
SUPPLY WHITE WIRE (NEUTRAL)
including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Refer to Figures 14 and 15 and connect the receiver wires to the supply wires and the fan motor wires as follows: a. Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor (this may be a bare wire or a wire with green insulation). Securely connect the supply white (neutral) wire to the receiver white (AC IN N) wire. Securely connect the supply black wire (hot) wire to the receiver black (AC IN L) wire. Securely connect the fan motor white wire to the receiver white (TO MOTOR N) wire. Securely connect the fan motor black wire to the receiver red (TO MOTOR L) wire. Securely connect the fan motor blue wire to the receiver blue (FOR LIGHT) wire. !
WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Noise and fan damage could result.
RECEIVER WHITE WIRE RECEIVER BLACK WIRE
AC IN
SUPPLY BLACK WIRE (HOT) GROUND WIRE
N
RECEIVER RED WIRE RECEIVER BLUE WIRE
TO MO
ANTENNA GREEN GROUND WIRE FROM HANGER BRACKET 1-1/4" THREADED STUD (2)
FAN BLACK WIRE FAN BLUE WIRE FAN WHITE WIRE
RECEIVER WHITE WIRE
Figure 14
11
FOR LI
GREEN GROUND WIRE FROM HANGER BALL
TOR N
AC IN L
GHT
TO M
OTO
RL
BP7308 LORRAINE KF240
2/15/06
3:21 PM
Page 12
SW101 FAN/LIGHT WALL CONTROL (SUPPLIED) TO 120VOLT SUPPLY BLACK (HOT)
OFF
BLACK
HI LIGHT MED
BLACK WHITE WHITE RED
LOW
FAN OFF
EMERSON®
ON
WHITE GROUND TWO-CONDUCTOR CABLE (WITH GROUND) GREEN WIRE (GROUND) FROM HANGER BALL AND HANGER BRACKET
BLUE BLACK BLUE WHITE
WHITE
Figure 15 3. Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket. Screw the two 1-1/4" threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 14). Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 16). Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling.
CEILING COVER
HANGER BALL
!
WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling. Screw in three 40-watt (maximum) candelabra bulbs in the light fitter sockets (Figure 17). Carefully place the lower glass over the light fitter threaded nipple. Be sure the glass is firmly seated on the fitter, then secure in place using a rubber washer, metal washer, and 1/8-27 nut (washers and nut are supplied). [. . . ] You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR. [. . . ]