User manual ELK PRODUCTS ELK-MK400

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ELK PRODUCTS ELK-MK400. We hope that this ELK PRODUCTS ELK-MK400 user guide will be useful to you.


ELK PRODUCTS ELK-MK400 : Download the complete user guide (2781 Ko)

Manual abstract: user guide ELK PRODUCTS ELK-MK400

Detailed instructions for use are in the User's Guide.

[. . . ] $10. 00 Magic Module ELK-MM443 - Field Programmable Controller Elk Development Software Covers Software Release Version 5. 1 ­ 16384 bytes of program memory. Note: MM443 Magic Modules were shipped with 16384 bytes of program memory as of August 1, 2000 . Note: Specifications and features may change without notice. Dallas iButton is a trademark of Dallas Semiconductor Inc. , Dallas, Texas PO Box 100 3266 US Hwy. 70 West Hildebran, NC 28637 USA 828/397-4200 FAX 828/397-4415 http://www. elkproducts. com Email: info@elkproducts. com Elk Products, Inc 1 Magic Module Instructions, Rev. [. . . ] Delete the existing Title Program Lines by highlighting them and pressing Delete, then 2. Execute "Insert Title" program again, located in the Edit drop down menu. Elk Products, Inc 46 Magic Module Instructions, Rev. 5. 3 L391 Simulator - Debugger The Simulator allows code written on the Code Editor to be executed and debugged under software control. Display windows are available to view timers, counters, registers, and stop the program at specific addresses. X-10 and Data Bus transmission and reception can be simulated to test the program function. Simulation Screen The Simulation Screen is the main simulator display screen, with the most used inputs and outputs displayed. Always Save the file when in the Code Editor, and then Open the file when starting the Simulator. Note: Some commands cannot be simulated using the Simulator-Debugger and will be skipped when the program executes, like the Dallas iButton, and multiple Magic Module communication on the data bus. Simulation should be limited to small routines. Receive X-10 Simulation: 1. "HOUSE" is set by the set RHOUSE value in the program and displayed in the HOUSE window. Set the UNIT code to be received with the drop down window at "Set Unit". Set the FUNCTION code to be received with the drop down window at "Set Function". The decimal Function Value will be calculated and displayed in the "Function Value" window. Click on the Receive X-10 button to simulate the reception of an X-10 signal. UVAL will hold the Unit Value, and FVAL will hold the Function Value to be used with an if statement for further program control. Input Level Simulation Adjust the sliding input bar on each input to simulate an input change. The High and Low Threshold levels will be displayed as well as the corresponding simulated input voltage levels. Elk Products, Inc 47 Magic Module Instructions, Rev. 5. 3 L391 Simulate Registers Displays timers, counters, and X-10 receive values. Stop 100ms Timer at a break - Every 100 milliseconds any timers that have been programmed with a time value are decremented. Normally the timers will continue to decrement when the program has been stopped by the simulator when an address that is set in the "Break At Address" in the Program Control Screen is executed. Update Data - A simulation program can be made to run faster by not updating the timers every 100 ms. Timers - Timer 1 through Timer 4 with tenths of a second, seconds, minutes, and hours are displayed in the timer display area. Counters - Counter 1 through Counter 4 count value are displayed in the Counter Data area. The count value may be initialized with the "set" command and compared with the "if" command. When receive X-10 is not being used, UVAL may be used as a temporary storage location. [. . . ] ; ;Data Area ; ;A - X-10 House Code to transmit ;_1 - X-10 Unit Code to transmit ;Off - X-10 Function Code to transmit ; ;A - X-10 House Code to transmit ;_1 - X-10 Unit Code to transmit ;On - X-10 Function Code to transmit Elk Products, Inc Page 89 Magic Module Instructions rev: 5. 3 L391 LIFETIME LIMITED WARRANTY Elk Products, Inc. ("Manufacturer") warrants to the original purchaser (the "Customer") that the products it manufactures ("Product") shall be free from defects in material and workmanship at time of shipment. Manufacturer's obligations under this Limited Warranty shall be limited to repairing or replacing, at its option, free of charge, any product returned to Manufacturer freight prepaid. Manufacturer shall have no obligation under this Limited Warranty or otherwise if (1) the Product has been damaged by negligence, accident, mishandling, lightning or flood, or other Acts of God, (2) the Product has not been operated in accordance with its operating instructions, (3) the Product has been altered or repaired by anyone outside Manufacturer's authorized facilities (4) adaptations or accessories have been made or attached to the Product which, in Manufacturer's sole determination, have adversely affected its performance, safety or reliability. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELK PRODUCTS ELK-MK400




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELK PRODUCTS ELK-MK400 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.