Detailed instructions for use are in the User's Guide.
[. . . ] * Try these other fine ELK products * Magic Module Series MM443 Magic Module, 4 Input, 4 Output, Programmable MM447 Automation Controller w/Voice, Caddx Interface MV480 Recordable Voice Module, 400 Channels MKHOME1 Home Control Kit for Caddx NX Controls MK400 Starter Kit, Includes MM443 & MK485 MK485 Programming Kit, MB485, Cables, Software MK410 X-10® Transceiver Kit, Programmed MM443 iButtonTM Access Kit w/ MM443, MA100, MA101 MK420 MA100 iButtonTM `Touchkey' Reader & Interface Pack iButtonTM `Touchkeys', 10 pcs w/keyring holders MA101 MA290 Proximity / Wiegand Data Interface to MM443 MB485 Data Bus Interface, RS232 to RS485 MC100 Clock / Calendar Module for MM443 ML8 Link Interface to Caddx NX Controls MT100 Temperature Sensor Module for MM443 MM220 Magic Module, 2 Input, 2 Output, Programmable Rust Free Sirens / Speakers 1RT Speaker & Stainless Steel Enclosure 150RT Siren & Stainless Steel Enclosure 155RT Voice Siren in Stainless Steel Box Speakers & Sirens 44 Speaker, 30 W, 8 Ohm Compact Horn 45 Siren, Compact Horn, 118db 55 Voice Siren, Compact Horn M120 Siren, Single Tone, 107db, Mini Horn SP15 Speaker, 15 watt, Small Horn SP30 Speaker, 30 watt, Horn SP35 Speaker, 20 watt, Interior SP40 Speaker, 40 watt, Horn SS15 Siren, Dual Tone, 110db, Horn SS30 Siren, Dual Tone, 120db, Horn SS36 Siren, Dual Tone, 105db, Interior ECHOTM Sirens & Speakers 73 ECHO Speaker, 20 Watt, Interior 74 ECHO Dual Tone Siren, Interior 75 ECHO Voice Siren, Interior 870 ECHO Speaker, Self Amplified Siren & Voice Drivers 100 High Performance Siren Driver 110 Voice Siren Driver, English & Spanish 120 Recordable Voice Module and Siren 124 Recordable Voice Module, 4 Channels Surge Suppressors 950 Surge Suppressor, Phone & Power Line 951 Surge Suppressor, Phone - Single Line 955 Surge Suppressor, Phone - Dual Line Relay Modules 912 Compact Relay, 12 Vdc, SPDT 912B Heavy Duty Compact Relay, 12/24 Vdc, SPDT 924 Sensitive Relay, 12/24 Vdc, DPDT 941 Alarm Output Director 960 Delay Timer Relay, 1 sec. Power Products 1240 Battery, Lead Acid, 12v, 5Ah 1270 Battery, Lead Acid, 12v, 8Ah 12100 Battery, Lead Acid, 12v, 12Ah 12170 Battery, Lead Acid, 12v, 18Ah 12250 Battery, Lead Acid, 12v, 25Ah P112 12 Volts DC, 1 Amp Power Supply w/Enclosure P124 24 Volts DC, 800mA Power Supply w/Enclosure P1216 12 Volts DC, 1. 5 Amp Power Supply P412 12 Volts DC, 4 Amp Power Supply P624 Power Supply & Battery Charger PD9 Power Distribution Module 965 Low Battery Cutoff and Power Switch TRG1640 Transformer, 16. 5VAC @ 40 VA TRG2440 Transformer, 24VAC @ 40 VA Accessories 129 Computer Sound Card Interface 800 Audio Amplifier, 10 Watts 900-2 "B" Connectors, Unfilled, 500 pcs 902-2 "B" Connectors, Gel filled, 500 pcs 980 Telephone Line Fault Monitor 998 Warning Alarm System Decals 999 Double Sided Tape SL1 Strobe Light, 4 colors available WK1 Wall Mount Kit for SL1 Strobes For more information contact your local Distributor or: ELK PRODUCTS, INC 828-397-4200 FAX 828-397-4415 http://www. elkproducts. com Email: info@elkproducts. com 05/02
Low Battery Cutoff & Master Power Switch
ELK-965
APPLICATION: The ELK-965 is a Low Battery Cutoff Module combined with a Master Power Switch. [. . . ] 70W · Hildebran, NC 28637 · USA
Instructions Printed On Inside
ELK-965 INSTRUCTIONS
The ELK-965 is extremely useful for adding a Master Power On / Off switch and an automatic low battery cutoff to virtually any 12 Volts D. C. Control Panel or Power Supply.
AC OUT Blue Wires (18") To AC Input of the Control or Power Supply SPADE LUGS For the Control or Power Supply Battery Wires
Installation
1. Disconnect AC transformer and battery from the Control or Power supply. Connect blue wires from the ELK-965 to the AC input of the Control or Power Supply. Connect red and black battery wires from the control or power supply to the male spade lugs on the ELK-965. Connect AC transformer wires to the terminals marked AC IN on the ELK-965. Connect red and black battery wires from the ELK-965 to the 12 Volt D. C. standby battery.
On / Off Power Switch
OFF
AC OUT J1
+RED
J2
-BLK
CONTROL
ELK-965
Note: The Control or Power Supply cannot be powered up from the battery only because the ELK-965 battery cutoff relay requires AC power to be on and the Control or Power Supply charging current to be verified before it will energize. .
SW1
Operation
POWER ON
Power On Indicates Status of AC Power * *
AC IN
+
BATTERY
-
In the event of an AC power outage the battery continues to provide power until it's voltage level drops to approximately 10 Volts. The ELK-965 will then disconnect the battery, thus shutting off the DC power to the device and saving the battery from a harmful deep discharge condition. The On / Off switch allows both the AC and DC (battery) power to be turned off to a control or power supply. [. . . ] Caution: The ELK-965 cannot determine the status or condition of a battery. This functionality would have to be provided by the control panel or power supply.
ON
AC INPUT From AC Transformer up to 18 Vac
BATTERY WIRES (16") (+) Red (-) Black To Standby Battery
ELK-965
Control Panel Hookup
Control Panel
AC Battery INPUT + -
18" Blue AC Wires Battery Wires From Control
AC OUT J1
+RED
J2
-BLK
CONTROL
OFF
On / Off Switch
ELK-965
ELK-965
ON
SW1
16" Battery Wires
POWER ON
AC Transformer 18 Vac max.
AC IN
+
BATTERY
-
+ 12V Battery
Power Supply Hookup
12V Power Supply
AC DC Out Batttery Input - +
+-
18" Blue AC Wires Power Supply Battery Wires
AC OUT J1
+RED
J2
-BLK
CONTROL
OFF
On / Off Switch
ELK-965
ON
SW1
16" Battery Wires
POWER ON ELK-965 BATTERY
AC Transformer 18 Vac max.
AC IN
+
-
+ 12V Battery [. . . ]