User manual ELK PRODUCTS ELK-941

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ELK PRODUCTS ELK-941. We hope that this ELK PRODUCTS ELK-941 user guide will be useful to you.


ELK PRODUCTS ELK-941 : Download the complete user guide (40 Ko)

Manual abstract: user guide ELK PRODUCTS ELK-941

Detailed instructions for use are in the User's Guide.

[. . . ] The input trigger can be either positive or negative (pull to ground). Alarm Output Director ELK-941 FEATURES · Separates Steady and Pulsing Voltage From a Single Alarm Output and Directs This Into Two (2) Different Relay Outputs. · Ideal For Two (2) Channel Long Range Radio or Cellular Transmitters. · LED Indication of Relay Status. SPECIFICATIONS · Operating Voltage: 12 Volts D. C. [. . . ] Upon determination of steady or pulse, the appropriate relay will activate and this output will cease. Note: If the trigger input is pulsing, this output will also pulse. J2 IMMEDIATE OUTPUT When an input trigger is first applied, the ELK-941 requires a 3 to 4 second verification time delay to determine if the input is steady or pulsing. If a siren is connected, it may be desirable to immediately activate one of the relays during this delay time. Jumper J2 selects which relay will activate (if any) during this time. If Relay 1 or 2 is selected for immediate output, the selected relay will "follow" the trigger. Once the ELK-941 has verified what type of input is being applied, the appropriate relay will then be activated (which may or may not be the same relay that was selected for immediate output). RELAY 1: With the jumper in this position Relay 1 will turn on during the verification time delay. RELAY 2: With the jumper in this position Relay 2 will turn on during the verification time delay. OFF: With the jumper in this position neither Relay will turn on during the verification time delay. Note: The -P terminal can be used to trigger a piezo or other low current device for audible or visual needs. The position of jumper J2 has no effect on the -P terminal. [N/O ] Relay 1 Normally Open contact. This terminal is connected with the COM terminal whenever the relay is ON (activated). This "pole" or switching part of the relay is connected to the N/O terminal when the relay is ON (activated), and to the N/C terminal when the relay is OFF (at rest). [N/C] Relay 1 Normally Closed contact. This terminal is connected with the COM terminal whenever the relay is OFF (at rest). [N/O ] Relay 2 Normally Open contact. This terminal is connected with the COM terminal whenever the relay is ON (activated). This "pole" or switching part of the relay is connected to the N/O terminal when the relay is ON (activated), and to the N/C terminal when the relay is OFF (at rest). [. . . ] J3 = "-" - Negative polarity alarm output (DSC type control). RELAY MODE IMMEDIATE OUTPUT J2 RELAY 1 RELAY 2 OFF 12V STROBE ELK-941 J1 TEMPORAL STEADY TRIGGER POLARITY J3 RELAY 1 RELAY 2 GND +12V +12V GND TRG + CH1 ACTIVE -P N/O COM N/C N/O COM N/C CH2 ACTIVE +12V AUX FROM CONTROL PANEL CONTROL PANEL GROUND ALARM OUTPUT FROM CONTROL Yelp + As shown, this hookup is used to activate a 12V strobe on Relay 2 when a pulsing output is detected. Both relays will stay on until input is removed if both a steady and pulsing input is detected. (Dual mode latch) Note: The 12V Aux output must be capable of supplying enough current to drive the strobe and the siren driver. - Stdy. - SIREN DRIVER PIEZO SOUNDER (PRE-ACTIVATION) Temporal coded bell from pulsing alarm output, Siren activation if alarm output is steady RELAY MODE IMMEDIATE OUTPUT J2 RELAY 1 RELAY 2 OFF Jumper Settings J1 = TEMPORAL - Output of Relay 2 will be Temporal 3 pulse pattern. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELK PRODUCTS ELK-941




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELK PRODUCTS ELK-941 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.