User manual ELECTRO-VOICE P2 REV B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ELECTRO-VOICE P2. We hope that this ELECTRO-VOICE P2 user guide will be useful to you.


ELECTRO-VOICE P2 REV B: Download the complete user guide (3187 Ko)

You may also download the following manuals related to this product:

   ELECTRO-VOICE P2 REV D (649 ko)

Manual abstract: user guide ELECTRO-VOICE P2REV B

Detailed instructions for use are in the User's Guide.

[. . . ] To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance. Use of a AC separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the AC. Switch off the power before retrofitting any extensions, changing the AC voltage or the output voltage. [. . . ] If any sign of weakness or damage is detected, remedial action should be taken immediately. There are data sheets for each EV hanging hardware part that should also be consulted prior to suspending speakers. · Electro-Voice® does not recommend use of Plasma speakers outdoors without protection from rain or in high moisture environments. · Electro-Voice® Plasma loudspeakers are easily capable of generating sound pressure levels sufficient to cause permanent hearing damage to anyone within normal coverage distance. Caution should be taken to avoid prolonged exposure to sound pressure levels exceeding 90 dB. 3 ELECTRO-VOICE® Plasma Owners Manual Description Electro-Voice® Plasma high powered loudspeakers are fully integrated audio systems with carefully matched electronics and transducers. These products make it easy to setup a highquality sound system quickly with a minimum of cables and external electronics. It retains typical EV ruggedness, reliability and impeccable sound quality. System Features - Plasma · Two built-in power amplifiers, one for low frequencies and one for high frequencies. The amplifiers also contain electronic crossover circuitry and CD horn compensation optimized for the speaker components a well as a limiter circuit that prevents either amplifier from clipping while preserving the sonic quality. · The low-frequency power amplifier delivers 500 watts continuous average power. · The high-frequency power amplifier delivers 150 watts continuous average power. · The subwoofer power amplifier delivers 800 watts continuous average power. · The line input utilizes Neutrik "combo" connectors, which will accept either ¼-inch or 3-pin XLRtype connectors. · The separate line output is a 3-pin XLR-type that can be used to connect additional systems. · The Plasma P1 two-way system is perfect for use as powered floor monitors. · Neutrik Powercon connectors are used for AC power connections. They provide a positive locking feature to prevent accidental disconnection. System Setup To get your Plasma system into operation as quickly as possible, please observe the following steps and precautions. · Plug the 3-terminal Powercon ac cable into a grounded line receptacle. Extension cords can be used to lengthen the ac cable as necessary but make sure that they are 3-conductor 14 gauge or greater, and that are properly grounded to avoid electrical hazards and extraneous noise. · Be sure that the Plasma system is plugged into an ac power source that is capable of supplying the correct voltage. If the line voltage drops too much, the built-in amplifiers won't be able to develop their rated power and sound quality will suffer. Under high signal conditions, the Plasma amplifier section can pull 3 ­ 4 amps of current (120 volt models) (2 amps at 240 volts). That means that no more than 4-Plasma systems should be plugged into a single 15 amp electrical service. Be cautious of what else is plugged into the same electrical service line to avoid electrical problems and poor performance. · BEFORE TURNING THE POWER ON, MAKE SURE THAT THE LEVEL CONTROLS ARE DOWN TO AVOID TRANSIENTS OR UNEXPECTED LOUD SOUND. [. . . ] Prior to each use, inspect the loudspeaker enclosures for any cracks, deformations, missing or damaged components, which could reduce enclosure strength. Inspect the track and bracket assembly on the enclosures for any cracks, deformations, missing or loose screws which could reduce the flying hardware strength. Never exceed the limitations or maximum recommended load for the Plasma systems. 9 ELECTRO-VOICE® Plasma Owners Manual Specifications Plasma P1 Freq. Range (-10 dB)1: 38 Hz - 19 kHz Calculated Max SPL: 132 dB Horizontal Coverage: 80° Vertical Coverage: 55° Amplifier Design: Class H THD: < 0. 01% Input Impedance: 20K LF Amplifier Power: 460 W RMS (550W Peak) HF Amplifier Power: 140 W RMS (150W Peak) High-Pass Crossover Fullrange: 45 Hz, 12 dB/Oct, Q=1. 2 (Switchable): Mid/High: 100 Hz, 24 dB/Oct, LinkwitzRiley Level Control: - to +6 dB LF Transducer: 15" (381 mm) EVX155RMD HF Transducer: 1. 4" (35. 6 mm) exit ND6 Comp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE P2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE P2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.