User manual ELECTRO-VOICE N8000-1500 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ELECTRO-VOICE N8000-1500. We hope that this ELECTRO-VOICE N8000-1500 user guide will be useful to you.


ELECTRO-VOICE N8000-1500 BROCHURE: Download the complete user guide (740 Ko)

Manual abstract: user guide ELECTRO-VOICE N8000-1500BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Mic or line level analog signals, as well as digital signals, are handled using the highest quality converters to ensure the best audio transmission. Additionally, the CM-1 allows CobraNet audio to be used for digital audio distribution over Ethernet networks. AUDIO SPECIFICATIONS Audio Inputs Input Connectors Input Level (nominal) Input Level (max. [. . . ] 2 x AI-1, 2 x AO-1, 1 x CM-1 modules) Left-to-right, 3-stage fan 32°F ­ 104°F (0 °C ­ 40 °C) 19" x 3. 5" x 15" (483 x 88. 1 x 381 mm) 2 RU MODULES / OPTIONS AI-1 Analog Input Module AO-1 Analog Output Module CM-1 CobraNetTM Module D0-1 Digital Output Module MI-1 Microphone Input Module DI-1 Digital Input Module 8 analog line level audio inputs, electronically balanced 8 analog line level audio outputs, electronically balanced 32 digital audio inputs and outputs, 2 CobraNetTM ports (Primary/Secondary) for network redundancy 8 AES/EBU outputs, Euroblock connectors, 48 kHz 8 mic/line level inputs, programmable Gain and Phantom Power, pad for line level switching, electronically balanced 8 AES/EBU or S/PDIF inputs, Euroblock or optical connector, 32-192 kHz SRC per input Bosch Communications Systems © 2008 Telex Communications, Inc. LIT000298000 Europe, Africa & Middle-East Headquarters EMEA EVI Audio GmbH Hirschberger Ring 45, 94315 Straubing, Germany Phone: +49 9421 706-0, Fax: +49 9421 706-265 France: EVI Audio France S. A. , Parc de Courcerin, Allée Lech Walesa, F 77185 Lognes, France Phone: +33 1-6480-0090 Fax: +33 1-6006-5103 UK: Shuttlesound, 4 The Willows Centre, Willow Lane, Mitcham, Surrey CR4 4NX, UK Phone: +44 208 646 7114 Fax: +44 208 254 5666 Asia & Pacific RimHeadquarter Asia Telex Communications (SEA) Pte Ltd 38C Jalan Pemimpin Singapore 577180 Tel: (65) 6319 0616 Fax: (65) 6319 0620 Japan: EVI Audio Japan, Ltd 5-3-8 Funabashi, Setagaya-ku, Tokyo 156-0055 Tel: +81 (3) 5316-5021 Fax: +81 (3) 5316-5031 Hong Kong: Telex EVI Audio (Hong Kong) Ltd. Room 508-509, 5/F, Topsail Plaza 11 On Shum Street Shek Mun, Shatin HK Phone: +852 2351-3628, Fax: +852 2351-3329 Shanghai: Telex EVI Audio (Shanghai) Co. , Ltd. Room 3105-3109, Tower 1 Office Building, 218 Tian Mu Xi Rd. , Shanghai, China Postal Code: 200070 Tel: +86 21-6317-2155 Fax : +86 21-6317-3025 DI-1 The DI-1 is an eightchannel digital input module for the NetMaxTM System Controller. Digital audio signals in AES/EBU or S/PDIF format are connected via screw-lockable Euro block connectors. Four ToslinkTM connectors for the optical transmission of digital audio signals are available. Internally the signals are processed in 48bit word length. CM-1 The CM-1 is CobraNetTM extension module for the NetmaxTM System Controller. The module provides 32 input and 32 output FULLY LICENSED channels of CobraNetTM compatible audio signals for extending the system capability. AmericasHeadquarter Americas Telex Communications, Inc. 12000 Portland Ave South, Burnsville, MN 55337, USA USA­Ph: 1-800-392-3497 Fax: 1-800-955-6831 Canada­Ph: 1-866-505-5551 Fax: 1-866-336-8467 Latin America­ Ph: 1-952-887-5532 Fax: 1-952-736-4212 IRIS-Net has always provided new and unique solutions for the pro sound market, providing tools, customization, and control that no other system can touch. EV's latest innovation is FIR-Drive technology -- a line array control platform within IRIS-Net. The FIR-Drive Line Array Controller provides a comprehensive system drive preconfigured with all the tools needed for the most demanding applications, including individual processing elements for main, array, and zone EQ, multiple subwoofer configurations, flexible auxiliary processing, and full routing options. Best of all, the control interface is laid out in a single high density interface to allow easy control of all array parameters from a single page. [. . . ] Arguably, the most important aspect of live sound is ensuring that the PA is healthy and performing properly. IRIS-Net and NetMax provide a unique set of tools for monitoring and supervising all aspects of the system including temperature, network status, fault conditions, and even cable integrity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE N8000-1500




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE N8000-1500 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.