User manual ELECTRO-VOICE ELX118P

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ELECTRO-VOICE ELX118P. We hope that this ELECTRO-VOICE ELX118P user guide will be useful to you.


ELECTRO-VOICE ELX118P : Download the complete user guide (2019 Ko)

Manual abstract: user guide ELECTRO-VOICE ELX118P

Detailed instructions for use are in the User's Guide.

[. . . ] To completely disconnect AC power from this apparatus, the power supply cord must be unplugged. Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on this apparatus. Management of WEEE (waste electrical and electronic equipment) (applicable in Member States of the European Union and other European countries with individual national policies on the management of WEEE) The symbol on the product or on its packaging indicates that this product may not be treated as regular household waste, but has to be disposed through returning it at an Electro-Voice dealer. FCC Information 1. Changes or modifications not expressly approved by the manufacturer could void the user's authority, granted by the FCC, to operate the equipment. [. . . ] Connect the AC power cord from a grounded line receptacle to MAINS IN. Connect a XLR, TRS or RCA cable from an audio source to INPUT 1 or INPUT 2. Slowly increase INPUT LEVEL and LOUDSPEAKER LEVEL to the desired volume 4 Electro-Voice Live X Series Powered Owner's Manual System Features ELX1 2P ­ 12" Two-Way Powered Loudspeaker 1 The ELX112P is a compact, powerful and versatile choice for sound reinforcement and stage monitoring applications -- lightweight and durable, with a 1000 W amp. · · · · · · · · · · · · · · · · · DH-1K 39mm (1. 5") Titanium Diaphragm Compression Driver EVS-12K 305mm (12") Woofer 50 Hz ­ 20 kHz Frequency Range; 132 dB Max SPL 1000 W Class D Lightweight Amplifier -- Runs Cool without Fans Bi-Amplified Design with 24 dB/Octave Filter Slopes and Transducer Protection Selectable 100 Hz High Pass Filter for Use with an External Subwoofer Dual XLR and TRS Combo Inputs with Independent Gain Control Stereo RCA Input with Gain Control on Input 1 Switchable Mic / Line Modes on Input 2 Switchable Normal / Boost Modes for Different Applications XLR Parallel Output with Selectable Pre or Post Mix Option Front-Mounted Power LED, Selectable On or Off Indicator Lights for Power on and Limit Pole Mounts or Stacks With Live X Subwoofers High Frequency Waveguide with 90° X 50° Coverage Pattern 15mm Plywood Enclosure, Internally Braced, With Textured Paint 60° Monitor Angle ELX1 15P ­ 15" Two-Way Powered Loudspeaker A powerful step up from the ELX112P, the 15" woofer and 1000 W amplifier in the ELX115P deliver extended lower frequencies and room-filling volume. · · · · · · · · · · · · · · · · · DH-1K 39mm (1. 5") Titanium Diaphragm Compression Driver EVS-15K 381mm (15") Woofer 44 Hz ­ 20 kHz Frequency Range; 134 dB Max SPL 1000 W Class D Lightweight Amplifier -- Runs Cool without Fans Bi-Amplified Design with 24 dB/Octave Filter Slopes and Transducer Protection Selectable 100 Hz High Pass Filter for Use with an External Subwoofer Dual XLR and TRS Combo Inputs with Independent Gain Control Stereo RCA Input with Gain Control on Input 1 Switchable Mic / Line Modes on Input 2 Switchable Normal / Boost Modes for Different Applications XLR Parallel Output with Selectable Pre or Post Mix Option Front-Mounted Power LED, Selectable On or Off Indicator Lights for Power on and Limit Pole Mounts or Stacks With Live X Subwoofers High Frequency Waveguide with 90° X 50° Coverage Pattern 15mm Plywood Enclosure, Internally Braced, With Textured Paint 60° Monitor Angle Electro-Voice Live X Series Powered Owner's Manual 5 System Features (cont') ELX1 18P ­ 18" Powered Subwoofer Optimized for performance with the ELX112P and ELX115P, the ELX118P adds a deep, low-frequency, amplified punch that you can hear and feel. · · · · · · · · · · EVS-18K 457mm (18") Woofer for Powerful, Engaging Bass Response 32 Hz ­ 130 Hz Frequency Range; 134 dB Max SPL 700 W Class D Lightweight Amplifier -- Runs Cool Without Fans Supports Pole Mount for Full-Range Systems XLR and TRS Combo Input Switchable Normal / Boost Modes for Different Applications XLR Parallel Output Front-Mounted Power LED, Selectable On or Off Indicator Lights for Power on and Limit 15mm Plywood Enclosure, Internally Braced, with Textured Paint 6 Electro-Voice Live X Series Powered Owner's Manual Tripod and Floor Monitor Operation Floor Monitor Electro-Voice ELX112P and ELX115P loudspeakers may be used as a floor monitor by placing the speaker on the integral monitor angle. Make sure to: · Place the speaker on a level, stable surface that is solid and secure. Make certain they are 3-conductor cables of suitable gauge and they are properly grounded to avoid electrical hazards and extraneous noise. Under high signal conditions, the Live X loudspeaker amplifier can draw 1. 0 amps of current at 120V, or 0. 6 amps at 230V. Be cautious of what else is plugged into the same electrical service line to avoid electrical problems and poor performance. If the LED is not lit upon turning the power on, make sure that the AC cord is correctly connected and the outlet is properly working. XLR/TRS INPUT Electronically balanced input for the connection of high-level signal sources like mixing consoles or signal processors. Connections can be established using 1/4" TRS or XLR-type connectors. INPUT 2 will accept a microphone input if MIC/LINE switch is depressed. MIC / LINE When depressed, activates a microphone preamp for use with dynamic microphones. Do not plug a line level signal into INPUT 2 when MIC/LINE is in the mic position. RCA INPUT Stereo unbalanced RCA inputs for connecting sources such as CD players or MP3 players. INPUT LEVEL Level control for adjusting the individual input's amplification. The level control affects the volume of the individual input section. 10 Electro-Voice Live X Series Powered Owner's Manual Amplifier Controls (cont') FULL RANGE / WITH SUB When switched to WITH SUB, activates a 100 Hz highpass for use with a subwoofer. Always select WITH SUB when using the ELX112P/ELX115P with a subwoofer for proper acoustic summation. NORMAL / BOOST The NORMAL/BOOST switch controls the tone of the loudspeaker. NORMAL works best when the loudspeaker is used for vocal monitors or for speech. Boost works best for music playback and applications that require more bass and treble boost. [. . . ] Excessive input level LIMIT LED is conLine level source constantly on or flashing nected to INPUT 2 regularly with MIC/LINE switch in MIC position 7. Source input (mixing console/preamp) is overdriven Incorrect gain structure Verify level controls of the source are properly structured. Reduce the microphone levels at the mixing console or input source. If the microphone is connected directly to the speaker reduce the input level on the speaker. Positioning the microphone close to the sound source will increase gain-beforefeedback. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE ELX118P




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE ELX118P will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.