User manual ELECTRIX BI-FILTER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ELECTRIX BI-FILTER. We hope that this ELECTRIX BI-FILTER user guide will be useful to you.


ELECTRIX BI-FILTER : Download the complete user guide (843 Ko)

Manual abstract: user guide ELECTRIX BI-FILTER

Detailed instructions for use are in the User's Guide.

[. . . ] 32-33 47th Avenue Long Island City, New York 11101 ph: 718 937 8300 fx: 718 937 9111 www. ehx. com User Reference Manual Manual Notice: This manual is provided as both a guide for instruction, as well as a reference to be kept near by to aid you in everyday use. In it you will find general information, regarding the Bi-Filter as well as instructions for real and suggested operating procedures, setup and use. Electro-Harmonix is not liable for errors, direct, indirect, coincidental, or as a consequence of material contained within this manual. Thank you for purchasing the ElectroHarmonix Bi-Filter. Please read this manual­written to be a reference guide that you can keep close by­in order to familiarize yourself with this unique instrument's layout. [. . . ] When the slider is in the FAST (DOWN) position, the envelope will rise with nearly the same attack as your instrument. When in the SLOW (UP) position, the envelope will rise slowly compared to the attack of your instrument. The range of the attack time is approximately 5 milliseconds to 1. 5 seconds. DECAY Slider: Controls the time response of the falling or "decay" portion of the signal envelope. When the slider is in the FAST (DOWN) position, the envelope will fall with nearly the same decay as your instrument. When in the SLOW (UP) position, the envelope will fall slowly compared to the decay of your instrument. The range of the decay time is approximately 10 milliseconds to 1. 5 seconds. Envelope Amount ENV AMOUNT Slider: Controls the amount and direction that the filter is swept by the envelope follower. In the 0 (CENTER) position, the envelope follower does not affect the filter. In the UP direction, the envelope sweeps the filter's frequency up from the frequency set by the FILTER FREQ slider. In the DOWN direction, the envelope sweeps the filter's frequency down from the frequency set by the FILTER FREQ slider. The amount of sweep is continuously variable depending on the control settings. NOTE: sweeping one of the filters UP and the other filter DOWN results in an "out of phase" complementary drive. Oscillator Amount OSC AMOUNT Slider: Controls the amount and direction of filter sweep by the SWEEP OSC (LFO). For both the UP and DOWN directions of the slider, the LFO sweeps the filter's frequency around the frequency set by the FILTER FREQ slider. In other words, the FILTER FREQ slider will set the center frequency and the LFO will sweep the filter above and below that center. So to sweep the entire frequency range, set the FILTER FREQ slider to MED (the center position) and set the OSC AMOUNT slider to either the maximum UP or DOWN positions. The difference between the UP and DOWN positions is that in the UP position the LFO is non-inverted, in the DOWN position the LFO waveform is inverted. If there is a rising sawtooth set up in the sweep oscillator section, and the OSC AMOUNT slider is set to the DOWN position, the waveform will become a falling sawtooth. NOTE: Setting the OSC AMOUNT of one filter UP and the other filter's OSC AMOUNT DOWN, results in an "out of phase" complementary drive. 7 Filters One and Two (Continued) Filter, Frequency and Range Controls FILTER FREQ Slider: Sets the filter frequency within its operating range. When no envelope or LFO signals are present, the frequency of the filter is set by the position of this slider. RANGE Switch: Changes the sweep range of the filter: LOW position gives the filter a sweep range from 150 Hz to 5 kHz. OVER/UNDER RANGE LEDs: Indicates that the filter is being swept to its limits of the frequency range. OVER RANGE RED LED: Indicates the frequency has been swept to or above the maximum range of the filter. [. . . ] NOTE: There will be no audio output from this jack when in bypass mode due to the TRUE BYPASS switching of the input signal. The signal on this jack is the output of the mixer section on the front panel. So there will be a mix of Filter 1, Filter 2 and the Dry input signal coming out of the MAIN OUTPUT jack. When in TRUE BYPASS mode, the DIRECT unmodified instrument signal will be output on this jack. 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRIX BI-FILTER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRIX BI-FILTER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.