User manual EINHELL BT-AC 200-24 0F

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EINHELL BT-AC 200-24 0F. We hope that this EINHELL BT-AC 200-24 0F user guide will be useful to you.


EINHELL BT-AC 200-24 0F : Download the complete user guide (825 Ko)

Manual abstract: user guide EINHELL BT-AC 200-24 0F

Detailed instructions for use are in the User's Guide.

[. . . ] Anleitung BT-AC 200-24 OF_SPK1:_ 28. 04. 2008 13:22 Uhr Seite 1 Bedienungsanleitung Kompressor Operating Instructions Compressor Instructions de service Compresseur Istruzioni per luso Compressore Brugsanvisning Kompressor Használati utasítás Kompresszor B f 4 j W Naputak za uporabu Kompresor Uputstva za upotrebu kompresora Návod k pouzití Kompresor Návod na obsluhu kompresora Art. -Nr. : 40. 205. 05 I. -Nr. : 01018 BT-AC 200/24 OF Anleitung BT-AC 200-24 OF_SPK1:_ 28. 04. 2008 13:22 Uhr Seite 2 Gebrauchsanweisung beachten!Bær høreværn Hordjon zajcsökkent hangvédt!Warnung vor elektrischer Spannung Beware of electrical voltage Attention à la tension électrique Fate attenzione alla tensione elettrica Advarsel mod elektrisk spænding Figyelmeztetés a villamos feszültség elöl Bf Upozorenje na elektricni napon 4 Upozorenje na elektricni napon j Varování ped elektrickým naptím W Výstraha pred elektrickým napätím Warnung vor heißen Teilen Beware of hot parts Attention aux pièces brûlantes Fate attenzione alle parti molto calde Advarsel mod varme dele Figyelmeztetés a forró részek elöl. Bf Upozorenje na vrue dijelove 4 Upozorenje na vrue delove j Varování ped horkými díly W Výstraha pred horúcimi dielmi 2 Anleitung BT-AC 200-24 OF_SPK1:_ 28. 04. 2008 13:22 Uhr Seite 3 1 7 9 1 5 2 3 11 4 2 8 10 3 8 6 6 5 e d a b c 1 7 3 3 3 Anleitung BT-AC 200-24 OF_SPK1:_ 28. 04. 2008 13:22 Uhr Seite 4 4 4 4 Anleitung BT-AC 200-24 OF_SPK1:_ 28. 04. 2008 13:23 Uhr Seite 11 GB Important! [. . . ] Technical data Power supply: Motor rating in kW/HP: Operating mode Compressor speed in rpm: Operating pressure in bar: Pressure vessel volume in litre: Theoretical intake rate in l/min. : Sound power level LWA in dB: Sound pressure level LpA in dB: Protection type: Machine weight in kg: 230 ~ 50 Hz 1. 1/1, 5 S3 25% 10 min 17500 8 24 176 94. 5 74. 5 IP 20 20 6. 1 Fitting the wheels (3) Fit the supplied wheels as shown in Fig. 6. 2 Fitting the supporting foot (4) Fit the supplied rubber stopper as shown in Fig. 6. 3 Voltage The compressor is equipped with a mains cable with shock-proof plug. This can be connected to any 230V ~ 50Hz shock-proof socket which is protected by a 16 A fuse. Before you use the machine, make sure that the mains voltage complies with the specifications on the rating plate. In the case of low temperatures below +5°C, motor start-up is jeopardized as a result of stiffness. 6. 4 On/Off switch (8) To switch on the equipment set the On/Off switch (8) to position 1. 1) You can adjust the pressure on the pressure gauge (6) using the pressure regulator (7). 6. 6 Setting the pressure switch The pressure switch is set at the factory. You must fully assemble the appliance before using it for the first time. Operating mode S3 - 25% - 10min: S3 = Intermittent mode without influencing the starting process. Points to note when setting up the compressor Examine the machine for signs of transit damage. Report any damage immediately to the company which delivered the compressor. The compressor may only be used in suitable rooms (with good ventilation and an ambient temperature from +5°C to +40°C). There must be no dust, acids, vapors, explosive gases or inflammable gases in the room. It is prohibited to use the compressor in areas where work is conducted with sprayed water. 13 Anleitung BT-AC 200-24 OF_SPK1:_ 28. 04. 2008 13:23 Uhr Seite 14 GB 7. Pull the power plug before doing any cleaning and maintenance work on the appliance. Always depressurize the tank before carrying out any cleaning and maintenance work. Disposal and recycling The unit is supplied in packaging to prevent its being damaged in transit. This packaging is raw material and can therefore be reused or can be returned to the raw material system. The unit and its accessories are made of various types of material, such as metal and plastic. Ask your dealer or your local council. Anleitung BT-AC 200-24 OF_SPK1:_ 28. 04. 2008 13:23 Uhr Seite 15 GB 10. Possible causes of failure Problem The compressor does not start Cause 1. [. . . ] Ne sont pas concernés les accessoires et ressources fournies sans composants électroniques. 58 Anleitung BT-AC 200-24 OF_SPK1:_ 28. 04. 2008 13:23 Uhr Seite 62 t GUARANTEE CERTIFICATE Dear Customer, All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card. Of course, if you would prefer to call us then we are also happy to offer our assistance under the service number printed below. Please note the following terms under which guarantee claims can be made: 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EINHELL BT-AC 200-24 0F




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EINHELL BT-AC 200-24 0F will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.